Magnetic resonance temperature imaging-based quantification of blood flow-related energy losses.

Christopher Dillon1, Robert Roemer2, Allison Payne1.   

Abstract

This study presents a new approach for evaluating bioheat transfer equation (BHTE) models used in treatment planning, control and evaluation of all thermal therapies. First, 3D magnetic resonance temperature imaging (MRTI) data are used to quantify blood flow-related energy losses, including the effects of perfusion and convection. Second, this information is used to calculate parameters of a BHTE model: in this paper the widely used Pennes BHTE. As a self-consistency check, the BHTE parameters are utilized to predict the temperatures from which they were initially derived. The approach is evaluated with finite-difference simulations and implemented experimentally with focused ultrasound heating of an ex vivo porcine kidney perfused at 0, 20 and 40 ml/min (n = 4 each). The simulation results demonstrate accurate quantification of blood flow-related energy losses, except in regions of sharp blood flow discontinuities, where the transitions are spatially smoothed. The smoothed transitions propagate into estimates of the Pennes perfusion parameter but have limited effect on the accuracy of temperature predictions using these estimates. Longer acquisition time periods mitigate the effects of MRTI noise, but worsen the effect of flow discontinuities. For the no-flow kidney experiments the estimates of a uniform, constant Pennes perfusion parameter are approximately zero, and at 20 and 40 ml/min the average estimates increase with flow rate to 3.0 and 4.2 kg/m(3) /s, respectively. When Pennes perfusion parameter values are allowed to vary spatially, but remain temporally constant, BHTE temperature predictions are more accurate than when using spatially uniform, constant Pennes perfusion values, with reductions in RMSE values of up to 79%. Locations with large estimated perfusion values correspond to high flow regions of the kidney observed in T1 -weighted MR images. This novel, MRTI-based technique holds promise for improving understanding of thermal therapy biophysics and for evaluating biothermal models.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  bioheat transfer; blood flow; high intensity focused ultrasound; magnetic resonance temperature imaging; thermal modeling

Mesh:

Year:  2015        PMID: 25973583      PMCID: PMC4510856          DOI: 10.1002/nbm.3318

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  45 in total

1.  Effects of physical parameters on high temperature ultrasound hyperthermia.

Authors:  B E Billard; K Hynynen; R B Roemer
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

2.  Blood flow cooling and ultrasonic lesion formation.

Authors:  M C Kolios; M D Sherar; J W Hunt
Journal:  Med Phys       Date:  1996-07       Impact factor: 4.071

3.  A description of discrete vessel segments in thermal modelling of tissues.

Authors:  A Kotte; G van Leeuwen; J de Bree; J van der Koijk; H Crezee; J Lagendijk
Journal:  Phys Med Biol       Date:  1996-05       Impact factor: 3.609

4.  A comparative analysis of thermal blood perfusion measurement techniques.

Authors:  R Kress; R Roemer
Journal:  J Biomech Eng       Date:  1987-08       Impact factor: 2.097

5.  The simulation of discrete vessel effects in experimental hyperthermia.

Authors:  R J Rawnsley; R B Roemer; A W Dutton
Journal:  J Biomech Eng       Date:  1994-08       Impact factor: 2.097

6.  A precise and fast temperature mapping using water proton chemical shift.

Authors:  Y Ishihara; A Calderon; H Watanabe; K Okamoto; Y Suzuki; K Kuroda; Y Suzuki
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

7.  Experimental evaluation of two simple thermal models using hyperthermia in muscle in vivo.

Authors:  E G Moros; A W Dutton; R B Roemer; M Burton; K Hynynen
Journal:  Int J Hyperthermia       Date:  1993 Jul-Aug       Impact factor: 3.914

8.  Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle.

Authors:  J De Poorter; C De Wagter; Y De Deene; C Thomsen; F Ståhlberg; E Achten
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

9.  Microvascular contributions in tissue heat transfer.

Authors:  M M Chen; K R Holmes
Journal:  Ann N Y Acad Sci       Date:  1980       Impact factor: 5.691

10.  Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

Authors:  L Chen; G ter Haar; C R Hill; M Dworkin; P Carnochan; H Young; J P Bensted
Journal:  Phys Med Biol       Date:  1993-11       Impact factor: 3.609

View more
  1 in total

1.  Analytical estimation of ultrasound properties, thermal diffusivity, and perfusion using magnetic resonance-guided focused ultrasound temperature data.

Authors:  C R Dillon; G Borasi; A Payne
Journal:  Phys Med Biol       Date:  2016-01-07       Impact factor: 3.609

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.