Literature DB >> 7110075

The effects of scatter in x-ray computed tomography.

P M Joseph, R D Spital.   

Abstract

The effects of detection of scattered radiation in x-ray transmission CT are studied both theoretically and experimentally. It is shown that scatter induces nonlinear errors in the measurement of attenuation values which can lead to cupping, streaks, and CT number inaccuracies. It is shown that scatter effects predominate over beam spectrum hardening effects for large body parts, and that the artifact propensity is a direct function of the scatter-to-primary ratio. The presence of scatter induced streaks were demonstrated experimentally on both a third and a fourth-generation CT scanner using an appropriate water-equivalent phantom. A simple model with constant scatter background leads to a correction algorithm which was tested on several phantoms and one human pelvis. The algorithm worked well on the smaller phantoms but was less successful for the larger objects. Nevertheless, it still gave substantial improvement in the pelvic scan. We demonstrated that, at least in the pelvis, scatter is a more significant source of error than beam hardening and that improved scatter correction algorithms are needed. The consequences for the quantitative interpretation of CT numbers for clinical diagnoses are discussed.

Entities:  

Mesh:

Year:  1982        PMID: 7110075     DOI: 10.1118/1.595111

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Soft tissue variations influence HR-pQCT density measurements in a spatially dependent manner.

Authors:  Po-Hung Wu; Tanvi Gupta; Hanling Chang; Dimitry Petrenko; Anne Schafer; Galateia Kazakia
Journal:  Bone       Date:  2020-06-27       Impact factor: 4.398

2.  Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms.

Authors:  Izuru Matsuda; Masaaki Akahane; Jiro Sato; Masaki Katsura; Shigeru Kiryu; Naoki Yoshioka; Akira Kunimatsu; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-02       Impact factor: 2.374

3.  Characterization and correction of cupping effect artefacts in cone beam CT.

Authors:  A K Hunter; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

Review 4.  Polyp size measurement at CT colonography: what do we know and what do we need to know?

Authors:  Ronald M Summers
Journal:  Radiology       Date:  2010-06       Impact factor: 11.105

5.  Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.

Authors:  Mohammad Reza Ay; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-19       Impact factor: 9.236

6.  Adaptive correction of the pseudo-enhancement of CT attenuation for fecal-tagging CT colonography.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Med Image Anal       Date:  2008-01-26       Impact factor: 8.545

7.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

8.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

9.  Characterization of X-ray scattering for various phantoms and clinical breast geometries using breast CT on a dedicated hybrid system.

Authors:  Jainil P Shah; Steve D Mann; Martin P Tornai
Journal:  J Xray Sci Technol       Date:  2017       Impact factor: 1.535

10.  Scale-based scatter correction for computer-aided polyp detection in CT colonography.

Authors:  Jiamin Liu; Jianhua Yao; Ronald M Summers
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.