Literature DB >> 14634733

[Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

K Wendl1, J von Recum, A Wentzensen, P A Grützner.   

Abstract

The mobile Siremobil Iso-C(3D) C-arm (Siemens AG, Medical Solutions, Erlangen) is the first device that permits the intraoperative three-dimensional (3D) representation of bone structures. A high-resolution isotropic 3D data cube in the isocenter with an edge length of approximately 12 cm is calculated simultaneously. The Siremobil Iso-C(3D) is linked to navigation with the integrated NaviLink interface (Siemens AG, Medical Solutions, Erlangen). This makes it possible to transfer the generated 3D data directly to the linked navigation system Surgigate (Medivision, Oberndorf, Switzerland). In this prospective clinical trial we evaluated the accuracy of pedicle screw placement using the Siremobil Iso-C(3D) C-arm. The results were compared to the conventional approach and other computer-assisted procedures (CT-based navigation, C-arm-based 2D navigation) in historical control groups. A total of 141 pedicle screws were placed in 30 patients (70 thoracic spine, 71 lumbar spine). Only in one single case was misplacement shown in the postoperative control CT scan (0.71%), the lowest rate of incorrect placements of all techniques. Also the lowest average fluoroscopy time (1.28+/-0.56 min) was achieved during the placement of pedicle screws on the spine with Iso-C(3D) navigation at a comparable average OR duration (103.26+/-23.3 min). There were no postoperative neurological complications in all 30 patients. From these data we conclude that Iso-C(3D) navigation of pedicle screws is a very accurate method in the correct placement of pedicle screws.

Entities:  

Mesh:

Year:  2003        PMID: 14634733     DOI: 10.1007/s00113-003-0683-9

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  15 in total

1.  A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation.

Authors:  L P Nolte; M A Slomczykowski; U Berlemann; M J Strauss; R Hofstetter; D Schlenzka; T Laine; T Lund
Journal:  Eur Spine J       Date:  2000-02       Impact factor: 3.134

Review 2.  Computer-assisted spine surgery.

Authors:  D Schlenzka; T Laine; T Lund
Journal:  Eur Spine J       Date:  2000-02       Impact factor: 3.134

3.  [Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study].

Authors:  M Arand; E Hartwig; D Hebold; L Kinzl; F Gebhard
Journal:  Unfallchirurg       Date:  2001-11       Impact factor: 1.000

4.  [Limits of CT-based computer navigation in spinal surgery].

Authors:  F Gebhard; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2000-08       Impact factor: 1.000

5.  Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients.

Authors:  T Laine; D Schlenzka; K Mäkitalo; K Tallroth; L P Nolte; H Visarius
Journal:  Spine (Phila Pa 1976)       Date:  1997-06-01       Impact factor: 3.468

6.  Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis.

Authors:  O Schwarzenbach; U Berlemann; B Jost; H Visarius; E Arm; F Langlotz; L P Nolte; C Ozdoba
Journal:  Spine (Phila Pa 1976)       Date:  1997-02-15       Impact factor: 3.468

7.  Planning and insertion of pedicle screws with computer assistance.

Authors:  U Berlemann; D Monin; E Arm; L P Nolte; C Ozdoba
Journal:  J Spinal Disord       Date:  1997-04

8.  Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine.

Authors:  L P Amiot; K Lang; M Putzier; H Zippel; H Labelle
Journal:  Spine (Phila Pa 1976)       Date:  2000-03-01       Impact factor: 3.468

9.  Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants.

Authors:  N Suhm; A L Jacob; L P Nolte; P Regazzoni; P Messmer
Journal:  Comput Aided Surg       Date:  2000

10.  Results of spinal arthrodesis with pedicle screw-plate fixation.

Authors:  J L West; D S Bradford; J W Ogilvie
Journal:  J Bone Joint Surg Am       Date:  1991-09       Impact factor: 5.284

View more
  17 in total

1.  Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study.

Authors:  Marcus Christian Müller; Peter Belei; Peter H Pennekamp; Koroush Kabir; Dieter C Wirtz; Christof Burger; Oliver Weber
Journal:  Int Orthop       Date:  2012-02-23       Impact factor: 3.075

2.  Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study.

Authors:  Sébastien Ruatti; C Dubois; E Chipon; G Kerschbaumer; M Milaire; A Moreau-Gaudry; J Tonetti; Ph Merloz
Journal:  Eur Spine J       Date:  2015-07-26       Impact factor: 3.134

3.  O-arm(®)-based spinal navigation and intraoperative 3D-imaging: first experiences.

Authors:  O Gonschorek; S Hauck; U Spiegl; T Weiß; R Pätzold; V Bühren
Journal:  Eur J Trauma Emerg Surg       Date:  2011-03-31       Impact factor: 3.693

4.  Focus on spinal navigation.

Authors:  O Gonschorek; V Bühren
Journal:  Eur J Trauma Emerg Surg       Date:  2011-04       Impact factor: 3.693

Review 5.  [Fracture of the calcaneus].

Authors:  H Zwipp; S Rammelt; S Barthel
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

6.  Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Authors:  D Briem; W Linhart; W Lehmann; P G Begemann; G Adam; U Schumacher; D M Cullinane; J M Rueger; J Windolf
Journal:  Eur Spine J       Date:  2005-07-12       Impact factor: 3.134

7.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

8.  [Integrated navigation. Preclinical evaluation and initial clinical experience].

Authors:  U Stöckle; A Schäffler; B König; N P Haas
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

9.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

Review 10.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.