Literature DB >> 22189965

Wear analysis of chamfered elongated acetabular cup liners.

Hsiao-Che Lin1, Tzuo-Liang Luo, Jian-Horng Chen.   

Abstract

This study investigated the wear phenomena of chamfered acetabular cup liners. The liners have three parameters at the lengthened rim: the length of the elongation, the depth of the cup and the chamfer angle. Using published wear volume equations for cylindrically elongated liners, this study analysed the volume of the chamfer to obtain the exact theoretical wear volume of the chamfered liner. The criteria described in our previous paper were used to verify the accuracy of the proposed methodology. The results showed that a shallow cup depth (<2 mm) and a chamfer angle of about 30° could significantly reduce the wear volume arising from the elongation. When the chamfer angle was increased further, this effect became progressively less significant. The results suggest that a chamfer angle up to about 30° is appropriate, but the angle should not be larger than required to obtain the minimum femoral range of motion (ROM). The results of this study can also be integrated with the analysis of the kinetics and kinematics of liners. A compromise design incorporating a lower wear volume, sufficient ROM and a lower contact stress should be possible.

Mesh:

Year:  2011        PMID: 22189965     DOI: 10.1007/s11517-011-0852-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  41 in total

1.  The effect of joint loading on acetabular wear measurement in total hip arthroplasty.

Authors:  J M Martell; S S Leopold; X Liu
Journal:  J Arthroplasty       Date:  2000-06       Impact factor: 4.757

2.  Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis.

Authors:  Tatsuro Mizoue; Kengo Yamamoto; Toshinori Masaoka; Atsuhiro Imakiire; Masao Akagi; Ian C Clarke
Journal:  J Orthop Sci       Date:  2003       Impact factor: 1.601

3.  Total hip arthroplasty in patients with osteonecrosis. The effect of cement techniques.

Authors:  M A Ritter; J Helphinstine; E M Keating; P M Faris; J B Meding
Journal:  Clin Orthop Relat Res       Date:  1997-05       Impact factor: 4.176

4.  An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups--wear, creep or degradation?

Authors:  G H Isaac; D Dowson; B M Wroblewski
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

5.  Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique.

Authors:  P A Devane; R B Bourne; C H Rorabeck; R M Hardie; J G Horne
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

6.  Cemented revision for aseptic acetabular loosening. A review of 387 hips.

Authors:  V V Raut; P D Siney; B M Wroblewski
Journal:  J Bone Joint Surg Br       Date:  1995-05

7.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Authors:  D H Sochart
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

8.  Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris.

Authors:  P A Devane; J G Horne; K Martin; G Coldham; B Krause
Journal:  J Arthroplasty       Date:  1997-04       Impact factor: 4.757

9.  Wear paths produced by individual hip-replacement patients--a large-scale, long-term follow-up study.

Authors:  D Bennett; L Humphreys; S O'Brien; C Kelly; J F Orr; D E Beverland
Journal:  J Biomech       Date:  2008-07-09       Impact factor: 2.712

10.  Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.

Authors:  Richard W McCalden; Steven J MacDonald; Cecil H Rorabeck; Robert B Bourne; David G Chess; Kory D Charron
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

View more
  3 in total

1.  Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

Authors:  C Quental; J Folgado; P R Fernandes; J Monteiro
Journal:  Med Biol Eng Comput       Date:  2014-11-02       Impact factor: 2.602

2.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

3.  Effects of design parameters of total hip components on the impingement angle and determination of the preferred liner skirt shape with an adequate oscillation angle.

Authors:  Hsiao-Che Lin; Wei-Min Chi; Ying-Jui Ho; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2012-11-29       Impact factor: 2.602

  3 in total