Dosimetric properties and clinical application of an a-Si EPID for dynamic IMRT quality assurance.

Kenji Matsumoto1, Masahiko Okumura, Yoshiyuki Asai, Kouhei Shimomura, Masaya Tamura, Yasumasa Nishimura.   

Abstract

Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of intensity-modulated radiation therapy (IMRT) were investigated as a replacement for conventional verification tools. The portal dosimetry system of Varian's EPID (aS1000) has an integrated image mode for portal dosimetry (PD). The source-to-imager distance was 105 cm, and there were no extra buildup materials on the surface of the EPID in this study. Several dosimetric properties were examined. For clinical dosimetry, the dose distributions of dynamic IMRT beams for prostate cancer (19 patients, 97 beams) were measured by EPID and compared with the results of ionization chamber (IC) measurements. In addition, pretreatment measurements for prostate IMRT (50 patients, 309 beams) were performed by EPID and were evaluated by the gamma method (criterion: 3 mm/3 %). The signal-to-monitor unit ratio of PD showed dose dependence, indicating ghosting effects. Tongue-and-groove effects were observed as a result of the dose difference in the measured EPID images. The results of PD for clinical IMRT beams were in good agreement with the predicted dose image with average values of 1.37 and 0.25 for γ (max) and γ (ave), respectively. The point doses of PD were slightly, but significantly, higher than the results of IC measurements (p < 0.05 paired t test). However, this small difference seems clinically acceptable. This portal dosimetry system is useful as a rapid and convenient verification tool for dynamic IMRT.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23208723     DOI: 10.1007/s12194-012-0190-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  30 in total

1.  Direct dose to water dosimetry for pretreatment IMRT verification using a modified EPID.

Authors:  Helen Gustafsson; Philip Vial; Zdenka Kuncic; Clive Baldock; James W Denham; Peter B Greer
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Two-dimensional ionization chamber arrays for IMRT plan verification.

Authors:  Bjoern Poppe; Arne Blechschmidt; Armand Djouguela; Ralf Kollhoff; Antje Rubach; Kay C Willborn; Dietrich Harder
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

3.  Investigation of an amorphous silicon EPID for measurement and quality assurance of enhanced dynamic wedge.

Authors:  Peter B Greer; Michael P Barnes
Journal:  Phys Med Biol       Date:  2007-01-25       Impact factor: 3.609

4.  Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.

Authors:  Markus Wendling; Robert J W Louwe; Leah N McDermott; Jan-Jakob Sonke; Marcel van Herk; Ben J Mijnheer
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

5.  Generation of discrete beam-intensity modulation by dynamic multileaf collimation under minimum leaf separation constraints.

Authors:  D J Convery; S Webb
Journal:  Phys Med Biol       Date:  1998-09       Impact factor: 3.609

6.  A technique for the quantitative evaluation of dose distributions.

Authors:  D A Low; W B Harms; S Mutic; J A Purdy
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

7.  Dosimetric characteristics of a liquid-filled electronic portal imaging device.

Authors:  M Essers; B R Hoogervorst; M van Herk; H Lanson; B J Mijnheer
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-12-01       Impact factor: 7.038

8.  Portal dosimetry using a liquid ion chamber matrix: dose response studies.

Authors:  Y Zhu; X Q Jiang; J Van Dyk
Journal:  Med Phys       Date:  1995-07       Impact factor: 4.071

9.  Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimation.

Authors:  J Stein; T Bortfeld; B Dörschel; W Schlegel
Journal:  Radiother Oncol       Date:  1994-08       Impact factor: 6.280

10.  Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device.

Authors:  L N McDermott; R J W Louwe; J J Sonke; M B van Herk; B J Mijnheer
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

View more
  4 in total

1.  The Influence of Acquisition Mode on the Dosimetric Performance of an Amorphous Silicon Electronic Portal Imaging Device.

Authors:  Omemh Bawazeer; Sisira Herath; Siva Sarasanandarajah; Tomas Kron; Pradip Deb
Journal:  J Med Phys       Date:  2017 Apr-Jun

2.  Radioluminescence characterization of in situ x-ray nanodosimeters: Potential real-time monitors and modulators of external beam radiation therapy.

Authors:  Jeffrey S Souris; Shih-Hsun Cheng; Charles Pelizzari; Nai-Tzu Chen; Patrick La Riviere; Chin-Tu Chen; Leu-Wei Lo
Journal:  Appl Phys Lett       Date:  2014-11-20       Impact factor: 3.791

3.  Implementation of intensity modulated radiotherapy for prostate cancer in a private radiotherapy service in Mexico.

Authors:  María Adela Poitevin-Chacón; Gabriel Reséndiz González; Adriana Alvarado Zermeño; Jesús Manuel Flores Castro; Christian Haydée Flores Balcázar; Samuel Rosales Pérez; Miguel Angel Pérez Pastenes; Alejandro Rodríguez Laguna; Patricio Vázquez Fernández; Alejandro Calvo Fernández; Jorge Bastida Ventura
Journal:  Rep Pract Oncol Radiother       Date:  2014-12-12

4.  Evaluation of Daily CT for EPID-Based Transit In Vivo Dosimetry.

Authors:  Bin Feng; Lei Yu; Enwei Mo; Liyuan Chen; Jun Zhao; Jiazhou Wang; Weigang Hu
Journal:  Front Oncol       Date:  2021-11-02       Impact factor: 6.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.