Investigation of an amorphous silicon EPID for measurement and quality assurance of enhanced dynamic wedge.

Peter B Greer1, Michael P Barnes.   

Abstract

This work assessed the dosimetric performance of an amorphous silicon electronic portal imaging device (EPID) for measurement and quality assurance of enhanced dynamic wedge (EDW) profile and wedge factor. EPID measurements of EDW profiles were corrected for pixel sensitivity variation and spectral over-response relative to ion chamber and compared to ion-chamber and diode-array measurements. The dependence of EPID measurements on wedge direction and source to EPID distance was assessed. The long-term stability was investigated by weekly measurement of EDW profiles and wedge factors over a seven month interval. An empirical correction method was developed to improve EPID profile agreement with diode-array measurements. The EPID profiles differed from conventional measurements by up to 5%. Backscatter from the EPID housing was also found to affect measurements by up to 4%, resulting in changes in EPID measured profile with the direction of the moving jaw and source to EPID distance. EPID profile measurements varied by a maximum of 0.3% (1 SD) within the umbra, and wedge factors varied by 0.3% (1 SD) over the seven month interval. The correction function improved agreement between EPID and diode array to within 2% for all wedge angles and energies. Due to the ease of use and reproducibility of the EPID-measured EDW profiles the device is highly suited to regular measurement of EDW.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17264371     DOI: 10.1088/0031-9155/52/4/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Dosimetric properties and clinical application of an a-Si EPID for dynamic IMRT quality assurance.

Authors:  Kenji Matsumoto; Masahiko Okumura; Yoshiyuki Asai; Kouhei Shimomura; Masaya Tamura; Yasumasa Nishimura
Journal:  Radiol Phys Technol       Date:  2012-12-04

2.  Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements.

Authors:  Borislava Petrovic; Aleksandra Grzadziel; Laza Rutonjski; Krzysztof Slosarek
Journal:  Radiol Oncol       Date:  2010-09-09       Impact factor: 2.991

3.  Comparison between an in-house 1D profile correction method and a 2D correction provided in Varian's PDPC Package for improving the accuracy of portal dosimetry images.

Authors:  Maritza A Hobson; Stephen D Davis
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Evaluation of the TrueBeam machine performance check (MPC) beam constancy checks for flattened and flattening filter-free (FFF) photon beams.

Authors:  Michael P Barnes; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2016-11-30       Impact factor: 2.102

5.  Calculation of exit dose for conformal and dynamically-wedged fields, based on water-equivalent path length measured with an amorphous silicon electronic portal imaging device.

Authors:  Awusi Kavuma; Martin Glegg; Mohamed Metwaly; Garry Currie; Alex Elliott
Journal:  J Appl Clin Med Phys       Date:  2011-03-03       Impact factor: 2.102

6.  Evaluation of the truebeam machine performance check (MPC): mechanical and collimation checks.

Authors:  Michael P Barnes; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2017-04-17       Impact factor: 2.102

7.  Long-term experience of MPC across multiple TrueBeam linacs: MPC concordance with conventional QC and sensitivity to real-world faults.

Authors:  Michael Pearson; David Eaton; Tony Greener
Journal:  J Appl Clin Med Phys       Date:  2020-08-13       Impact factor: 2.102