Portal dosimetry using a liquid ion chamber matrix: dose response studies.

Y Zhu1, X Q Jiang, J Van Dyk.   

Abstract

Current intensive investigations of electronic portal imaging devices (EPIDs) have prompted their potential application to portal dosimetry. In this paper, the progress made in using a commercial liquid ion chamber matrix EPID for portal dosimetry is discussed. The pixel value of the liquid ion chamber element was calibrated against dose by exposing the imager to 6-MV x-ray beams of various intensities obtained with various thicknesses of lead attenuators and a range of source to detector distances. Absolute dose values were determined using an ion chamber on the central axis at the depth of maximum dose in a solid water phantom. The pixel values of the matrix were determined for various field sizes in order to evaluate the dependence of pixel value on dose at those field sizes. It was confirmed that the pixel value was proportional to the square root of the dose rate and was nearly independent of the field size. The 2D pixel values were converted to 2D dose maps in the water phantom after applying a correction for the effect of horns in the flood calibration field. The flood calibration field was used to obtain the relative sensitivity of each pixel. Good agreement was observed (normally better than 1% in relative standard deviation) between the converted dose distribution obtained from the pixel matrix and the direct dose measurement using an ion chamber scanned in a water phantom in regions of shallow dose gradient. For application to on-line portal dosimetry, both the short- and long-term stability of this EPID system were found to be within 1% relative standard deviation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7565384     DOI: 10.1118/1.597502

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Dose verifications by use of liquid ionization chamber of an electronic portal imaging device (EPID).

Authors:  Kunihiko Tateoka; Atsushi Oouchi; Kensei Nakata; Masato Hareyama
Journal:  Radiol Phys Technol       Date:  2008-06-07

2.  Simple proposal for dosimetry with an Elekta iViewGT™ electronic portal imaging device (EPID) using commercial software modules.

Authors:  Janett Liebich; Jörg Licher; Christian Scherf; Eugen Kara; Nadine Koch; Claus Rödel; Ulla Ramm
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

3.  Dosimetric properties and clinical application of an a-Si EPID for dynamic IMRT quality assurance.

Authors:  Kenji Matsumoto; Masahiko Okumura; Yoshiyuki Asai; Kouhei Shimomura; Masaya Tamura; Yasumasa Nishimura
Journal:  Radiol Phys Technol       Date:  2012-12-04

4.  Implementation and validation of a commercial portal dosimetry software for intensity-modulated radiation therapy pre-treatment verification.

Authors:  C Varatharaj; Eugenia Moretti; M Ravikumar; Maria Rosa Malisan; Sanjay S Supe; Renato Padovani
Journal:  J Med Phys       Date:  2010-10

5.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

6.  Feasibility of using two-dimensional array dosimeter for in vivo dose reconstruction via transit dosimetry.

Authors:  Heeteak Chung; Jonathan Li; Sanjiv Samant
Journal:  J Appl Clin Med Phys       Date:  2011-04-08       Impact factor: 2.102

7.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.