Multiple-mouse MRI with multiple arrays of receive coils.

Marc S Ramirez1, Emilio Esparza-Coss, James A Bankson.   

Abstract

Compared to traditional single-animal imaging methods, multiple-mouse MRI has been shown to dramatically improve imaging throughput and reduce the potentially prohibitive cost for instrument access. To date, up to a single radiofrequency coil has been dedicated to each animal being simultaneously scanned, thus limiting the sensitivity, flexibility, and ultimate throughput. The purpose of this study was to investigate the feasibility of multiple-mouse MRI with a phased-array coil dedicated to each animal. A dual-mouse imaging system, consisting of a pair of two-element phased-array coils, was developed and used to achieve acceleration factors greater than the number of animals scanned at once. By simultaneously scanning two mice with a retrospectively gated cardiac cine MRI sequence, a 3-fold acceleration was achieved with signal-to-noise ratio in the heart that is equivalent to that achieved with an unaccelerated scan using a commercial mouse birdcage coil. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20146352      PMCID: PMC2901989          DOI: 10.1002/mrm.22236

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  34 in total

1.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

Authors:  P Kellman; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Partially parallel imaging with localized sensitivities (PILS).

Authors:  M A Griswold; P M Jakob; M Nittka; J W Goldfarb; A Haase
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

4.  Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

Authors:  W E Kyriakos; L P Panych; D F Kacher; C F Westin; S M Bao; R V Mulkern; F A Jolesz
Journal:  Magn Reson Med       Date:  2000-08       Impact factor: 4.668

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Super-parallel MR microscope.

Authors:  Yoshimasa Matsuda; Shin Utsuzawa; Takeaki Kurimoto; Tomoyuki Haishi; Yukako Yamazaki; Katsumi Kose; Izumi Anno; Mitsuhiro Marutani
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

7.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

8.  MRI of mouse models for gliomas shows similarities to humans and can be used to identify mice for preclinical trials.

Authors:  Jason A Koutcher; Xiaoyi Hu; Su Xu; Terence P F Gade; Norman Leeds; Xiaohong Joe Zhou; David Zagzag; Eric C Holland
Journal:  Neoplasia       Date:  2002 Nov-Dec       Impact factor: 5.715

9.  In vivo multiple-mouse imaging at 1.5 T.

Authors:  S Xu; T P F Gade; C Matei; K Zakian; A A Alfieri; X Hu; E C Holland; S Soghomonian; J Tjuvajev; D Ballon; J A Koutcher
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

10.  Multiple-mouse MRI.

Authors:  Nicholas A Bock; Norman B Konyer; R Mark Henkelman
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

View more
  6 in total

1.  Feasibility of multianimal hyperpolarized (13) C MRS.

Authors:  Marc S Ramirez; Jaehyuk Lee; Christopher M Walker; Yunyun Chen; Charles V Kingsley; Jorge De La Cerda; Kiersten L Maldonado; Stephen Y Lai; James A Bankson
Journal:  Magn Reson Med       Date:  2014-06-05       Impact factor: 4.668

2.  A throughput-optimized array system for multiple-mouse MRI.

Authors:  Marc S Ramirez; Stephen Y Lai; James A Bankson
Journal:  NMR Biomed       Date:  2012-08-10       Impact factor: 4.044

3.  INTERCOMPARISON OF PERFORMANCE OF RF COIL GEOMETRIES FOR HIGH FIELD MOUSE CARDIAC MRI.

Authors:  Christakis Constantinides; S Angeli; S Gkagkarellis; G Cofer
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2011-09       Impact factor: 0.481

4.  Functional and morphological cardiac magnetic resonance imaging of mice using a cryogenic quadrature radiofrequency coil.

Authors:  Babette Wagenhaus; Andreas Pohlmann; Matthias Alexander Dieringer; Antje Els; Helmar Waiczies; Sonia Waiczies; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  PLoS One       Date:  2012-08-01       Impact factor: 3.240

5.  Accelerating cine-MR imaging in mouse hearts using compressed sensing.

Authors:  Tobias Wech; Angela Lemke; Debra Medway; Lee-Anne Stork; Craig A Lygate; Stefan Neubauer; Herbert Köstler; Jürgen E Schneider
Journal:  J Magn Reson Imaging       Date:  2011-09-19       Impact factor: 4.813

6.  Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla.

Authors:  Jürgen E Schneider; Titus Lanz; Hannah Barnes; Lee-Anne Stork; Steffen Bohl; Craig A Lygate; Roger J Ordidge; Stefan Neubauer
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.