Literature DB >> 17451179

Mouse MRI using phased-array coils.

Daniel Gareis1, Tobias Wichmann, Titus Lanz, Gerd Melkus, Michael Horn, Peter M Jakob.   

Abstract

The advantages of array coil imaging in human whole-body MR systems are well known and have gained relevance in many applications and MR techniques. In the field of small-animal studies, this concept has become increasingly important. In this work, three different phased-array coils for performing MRI on mice are presented. For imaging at 300 MHz, a four-channel receive-only phased-array coil is introduced. One two-channel and a four-channel transmit/receive setup operating at 750 MHz show the feasibility of array coil imaging at 17.6 T. All of these coils show excellent performance and deliver high-quality MR images of mice. Copyright (c) 2007 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2007        PMID: 17451179     DOI: 10.1002/nbm.1156

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  13 in total

1.  Surface coil with reduced specific absorption rate for rat MRI at 7 T.

Authors:  Sergio E Solis-Najera; Rodrigo Martin; Fabian Vazquez; Alfredo O Rodriguez
Journal:  MAGMA       Date:  2015-10-08       Impact factor: 2.310

Review 2.  Small animal imaging with magnetic resonance microscopy.

Authors:  Bastiaan Driehuys; John Nouls; Alexandra Badea; Elizabeth Bucholz; Ketan Ghaghada; Alexandra Petiet; Laurence W Hedlund
Journal:  ILAR J       Date:  2008

3.  Hardware Considerations for Preclinical Magnetic Resonance of the Kidney.

Authors:  Paula Ramos Delgado; Ekkehard Küstermann; André Kühne; Jason M Millward; Thoralf Niendorf; Andreas Pohlmann; Martin Meier
Journal:  Methods Mol Biol       Date:  2021

4.  A parallel imaging approach to wide-field MR microscopy.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

5.  A 20-channel receive-only mouse array coil for a 3 T clinical MRI system.

Authors:  Boris Keil; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald; Florian M Meise; Laura M Schreiber; Klaus J Klose; Johannes T Heverhagen
Journal:  Magn Reson Med       Date:  2011-03-23       Impact factor: 4.668

6.  Magnetic resonance image enhancement by reducing receptors' effective size and enabling multiple channel acquisition.

Authors:  Fernando Yepes-Calderon; Adriana Velasquez; Natasha Lepore; Olivier Beuf
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

7.  INTERCOMPARISON OF PERFORMANCE OF RF COIL GEOMETRIES FOR HIGH FIELD MOUSE CARDIAC MRI.

Authors:  Christakis Constantinides; S Angeli; S Gkagkarellis; G Cofer
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2011-09       Impact factor: 0.481

8.  In vivo high-resolution diffusion tensor imaging of the mouse brain.

Authors:  Dan Wu; Jiadi Xu; Michael T McMahon; Peter C M van Zijl; Susumu Mori; Frances J Northington; Jiangyang Zhang
Journal:  Neuroimage       Date:  2013-06-12       Impact factor: 6.556

9.  Initial in vivo rodent sodium and proton MR imaging at 21.1 T.

Authors:  Victor D Schepkin; William W Brey; Peter L Gor'kov; Samuel C Grant
Journal:  Magn Reson Imaging       Date:  2010-01-04       Impact factor: 2.546

10.  Three-element phased-array coil for imaging of rat spinal cord at 7T.

Authors:  Kishore V Mogatadakala; James A Bankson; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more