CoCrMo metal-on-metal hip replacements.

Yifeng Liao1, Emily Hoffman, Markus Wimmer, Alfons Fischer, Joshua Jacobs, Laurence Marks.   

Abstract

After the rapid growth in the use of CoCrMo metal-on-metal hip replacements since the second generation was introduced circa 1990, metal-on-metal hip replacements have experienced a sharp decline in the last two years due to biocompatibility issues related to wear and corrosion products. Despite some excellent clinical results, the release of wear and corrosion debris and the adverse response of local tissues have been of great concern. There are many unknowns regarding how CoCrMo metal bearings interact with the human body. This perspective article is intended to outline some recent progresses in understanding wear and corrosion of metal-on-metal hip replacement both in vivo and in vitro. The materials, mechanical deformation, corrosion, wear-assisted corrosion, and wear products will be discussed. Possible adverse health effects caused by wear products will be briefly addressed, as well as some of the many open questions such as the detailed chemistry of corrosion, tribochemical reactions and the formation of graphitic layers. Nowadays we design almost routinely for high performance materials and lubricants for automobiles; humans are at least as important. It is worth remembering that a hip implant is often the difference between walking and leading a relatively normal life, and a wheelchair.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23196425      PMCID: PMC3530782          DOI: 10.1039/c2cp42968c

Source DB:  PubMed          Journal:  Phys Chem Chem Phys        ISSN: 1463-9076            Impact factor:   3.676


  54 in total

1.  Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. II. Analysis of ion release and particle composition.

Authors:  I Catelas; J D Bobyn; J J Medley; D J Zukor; A Petit; O L Huk
Journal:  J Biomed Mater Res       Date:  2001-06-05

2.  Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape.

Authors:  I Catelas; J D Bobyn; J B Medley; J J Krygier; D J Zukor; A Petit; O L Huk
Journal:  J Biomed Mater Res       Date:  2001-06-05

3.  Analysis of mixed lubrication mechanism in metal-on-metal hip joint replacements.

Authors:  Z M Jin
Journal:  Proc Inst Mech Eng H       Date:  2002       Impact factor: 1.617

4.  Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator.

Authors:  P J Firkins; J L Tipper; M R Saadatzadeh; E Ingham; M H Stone; R Farrar; J Fisher
Journal:  Biomed Mater Eng       Date:  2001       Impact factor: 1.300

5.  The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.

Authors:  S L Smith; D Dowson; A A Goldsmith
Journal:  Proc Inst Mech Eng H       Date:  2001       Impact factor: 1.617

6.  Systemic distribution of wear debris after hip replacement. A cause for concern?

Authors:  V G Langkamer; C P Case; P Heap; A Taylor; C Collins; M Pearse; L Solomon
Journal:  J Bone Joint Surg Br       Date:  1992-11

7.  Comparison of friction and lubrication of different hip prostheses.

Authors:  S C Scholes; A Unsworth
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

8.  Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results.

Authors:  L D Dorr; Z Wan; D B Longjohn; B Dubois; R Murken
Journal:  J Bone Joint Surg Am       Date:  2000-06       Impact factor: 5.284

9.  Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement.

Authors:  R M Urban; J J Jacobs; M J Tomlinson; J Gavrilovic; J Black; M Peoc'h
Journal:  J Bone Joint Surg Am       Date:  2000-04       Impact factor: 5.284

10.  A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.

Authors:  A A Goldsmith; D Dowson; G H Isaac; J G Lancaster
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

View more
  18 in total

Review 1.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

2.  Distributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients.

Authors:  Ove Furnes; Elizabeth Paxton; Guy Cafri; Stephen Graves; Barbara Bordini; Thomas Comfort; Moises Coll Rivas; Samprit Banerjee; Art Sedrakyan
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

3.  Investigation of CoCrMo material loss in a novel bio-tribometer designed to study direct cell reaction to wear and corrosion products.

Authors:  S Radice; T Holcomb; R Pourzal; N J Hallab; M P Laurent; M A Wimmer
Journal:  Biotribology (Oxf)       Date:  2019-03-27

4.  Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement.

Authors:  Marzieh M Ardestani; Pedro P Amenábar Edwards; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2017-03-02       Impact factor: 4.176

Review 5.  Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

Authors:  Divya Rani Bijukumar; Abhijith Segu; Júlio C M Souza; XueJun Li; Mark Barba; Louis G Mercuri; Joshua J Jacobs; Mathew Thoppil Mathew
Journal:  Nanomedicine       Date:  2018-01-12       Impact factor: 5.307

6.  Differential toxicity of processed and non-processed states of CoCrMo degradation products generated from a hip simulator on neural cells.

Authors:  Divya Rani Bijukumar; Abhijith Segu; YongChao Mou; Reza Ghodsi; Tolou Shokufhar; Mark Barba; Xue-Jun Li; Mathew Thoppil Mathew
Journal:  Nanotoxicology       Date:  2018-09-25       Impact factor: 5.913

Review 7.  Surface Texturing of Prosthetic Hip Implant Bearing Surfaces: A Review.

Authors:  Quentin Allen; Bart Raeymaekers
Journal:  J Tribol       Date:  2020-10-05       Impact factor: 2.045

8.  Platinum dissolution and tissue response following long-term electrical stimulation at high charge densities.

Authors:  Robert K Shepherd; Paul M Carter; Ashley N Dalrymple; Ya Lang Enke; Andrew K Wise; Trung Nguyen; James Firth; Alex Thompson; James B Fallon
Journal:  J Neural Eng       Date:  2021-03-17       Impact factor: 5.379

9.  Non-invasive early detection of failure modes in total hip replacements (THR) via acoustic emission (AE).

Authors:  Christine Lee; Lu Zhang; Dalton Morris; Kai Yuan Cheng; Remya Ampadi Ramachandran; Mark Barba; Divya Bijukumar; Didem Ozevin; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-19

10.  Cobalt Cardiomyopathy Secondary to Hip Arthroplasty: An Increasingly Prevalent Problem.

Authors:  Russel Tilney; Melanie Roberta Burg; Mark Adrian Sammut
Journal:  Case Rep Cardiol       Date:  2017-08-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.