Non-invasive early detection of failure modes in total hip replacements (THR) via acoustic emission (AE).

Christine Lee1, Lu Zhang2, Dalton Morris3, Kai Yuan Cheng4, Remya Ampadi Ramachandran4, Mark Barba5, Divya Bijukumar3, Didem Ozevin6, Mathew T Mathew7.   

Abstract

Total hip replacements (THR) are becoming an common orthopedic surgucal procedure in the United States (332 K/year in 2017) to relieve pain and improve the mobility of those that are affected by osteoarthritis, ankylosing spondylitis, or injury. However, complications like tribocorrosion, or material degradation due to friction and corrosion, may result in THR failure. Unfortunately, few strategies to non-invasively diagnose early-stage complications are reported in literature, leading to implant complications being detected after irreversible damage. Therefore, the main objective of this study proposes the utilization of acoustic emission (AE) to continuously monitor implant materials, CoCrMo and Ti6Al4V, and identify degradations formed during cycles of sleeping, standing, and walking by correlating them to potential and friction coefficient behavior. AE activity detected from the study correlates with the friction coefficient and open-circuit potential observed during recreated in-vitro standing, walking, and sleeping cycles. It was found that the absolute energy level obtained from AE increased as the friction coefficient increased, potential decreased, and wear volume loss increased. Through the results, higher friction coefficient and AE activity were observed in Ti6Al4V alloys while there was also a significant drop in potential, indicating increased tribocorrosion activity. Therefore, AE can be utilized to predict material degradations as a non-invasive method based on the severity of abnormality of the absolute energy and hits emitted. The correlation between potential, friction coefficient, and AE activity was further confirmed through profilometry which showed more material degradation in Ti6Al4V than CoCrMo. Through these evaluations, it was demonstrated that AE could be utilized to identify the deformations and failure modes of implant materials caused by tribocorrosion.
Copyright © 2021. Published by Elsevier Ltd.

Entities:  

Keywords:  Acoustic emission (AE); Monitoring; Non-invasive technique; Total hip replacements (THR); Tribocorrosion mechanisms

Mesh:

Substances:

Year:  2021        PMID: 33773236      PMCID: PMC8457039          DOI: 10.1016/j.jmbbm.2021.104484

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  13 in total

1.  Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030.

Authors:  Steven Kurtz; Kevin Ong; Edmund Lau; Fionna Mowat; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2007-04       Impact factor: 5.284

2.  Monitoring the integrity of the cement-metal interface of total joint components in vitro using acoustic emission and ultrasound.

Authors:  J P Davies; M K Tse; W H Harris
Journal:  J Arthroplasty       Date:  1996-08       Impact factor: 4.757

Review 3.  Acoustic emission in orthopaedics: A state of the art review.

Authors:  Richard A Kapur
Journal:  J Biomech       Date:  2016-10-28       Impact factor: 2.712

4.  Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems.

Authors:  M T Mathew; M J Runa; M Laurent; J J Jacobs; L A Rocha; M A Wimmer
Journal:  Wear       Date:  2011-07-29       Impact factor: 3.892

Review 5.  Bio-functional nano-coatings on metallic biomaterials.

Authors:  Anil Mahapatro
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-05-09       Impact factor: 7.328

6.  Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique.

Authors:  A Roques; M Browne; J Thompson; C Rowland; A Taylor
Journal:  Biomaterials       Date:  2004-02       Impact factor: 12.479

Review 7.  Hip implant performance prediction by acoustic emission techniques: a review.

Authors:  Ampadi R Remya; B Vishwash; Christine Lee; P Srinivasa Pai; Alejandro A Espinoza Oras; Didem Ozevin; Mathew T Mathew
Journal:  Med Biol Eng Comput       Date:  2020-06-12       Impact factor: 2.602

8.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

9.  Flexible Molybdenum Electrodes towards Designing Affinity Based Protein Biosensors.

Authors:  Vikramshankar Kamakoti; Anjan Panneer Selvam; Nandhinee Radha Shanmugam; Sriram Muthukumar; Shalini Prasad
Journal:  Biosensors (Basel)       Date:  2016-07-18

Review 10.  Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants.

Authors:  João Henrique Cachão; Marco P Soares Dos Santos; Rodrigo Bernardo; António Ramos; Rainer Bader; Jorge A F Ferreira; António Torres Marques; José A O Simões
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.