Comparison of friction and lubrication of different hip prostheses.

S C Scholes1, A Unsworth.   

Abstract

It is well documented that an important cause of osteolysis and subsequent loosening of replacement hip joints is polyethylene wear debris. To avoid this, interest has been renewed in metal-on-metal and ceramic-on-ceramic prostheses. Various workers have assessed the lubrication modes of different joints by measuring the friction at the bearing surfaces, using different lubricants. Measurements of friction factors of a series of hip prostheses were undertaken using carboxymethyl cellulose (CMC) fluids, silicone fluids, synovial fluid and different concentrations of bovine serum as the lubricant. The experimental results were compared with theoretical predictions of film thicknesses and lubrication modes. A strong correlation was observed between experiment and theory when employing CMC fluids or silicone fluids as the lubricant. Mixed lubrication was found to occur in the metal-on-metal (CoCrMo/CoCrMo) joints with all lubricants at a viscosity within the physiological range. This was also the case for the metal-on-plastic (CoCrMo/ultra-high molecular weight polyethylene) joints. The ceramic-on-ceramic (Al2O3/Al2O3) joints, however, exhibited full fluid film lubrication with the synthetic lubricants but mixed lubrication with the biological lubricants. Employing a biological fluid as the lubricant affected the friction to varying degrees when compared with the synthetic lubricants. In the case of the ceramic-on-ceramic joints it acted to increase the friction factor tenfold; however, for the metal-on-metal joints, biological fluids gave slightly lower friction than the synthetic lubricants did. This suggests that, when measuring friction and wear of artificial joints, a standard lubricant should be used.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10718050     DOI: 10.1243/0954411001535237

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  14 in total

1.  Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating.

Authors:  Qian Qian Wang; Jun Jie Wu; Anthony Unsworth; Adam Briscoe; Marcus Jarman-Smith; Conor Lowry; David Simpson; Simon Collins
Journal:  J Mater Sci Mater Med       Date:  2012-03-28       Impact factor: 3.896

2.  Hierarchy of stability factors in reverse shoulder arthroplasty.

Authors:  Sergio Gutiérrez; Tony S Keller; Jonathan C Levy; William E Lee; Zong-Ping Luo
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  Squeaking hips.

Authors:  William L Walter; Tim S Waters; Mark Gillies; Shane Donohoo; Steven M Kurtz; Amar S Ranawat; William J Hozack; Michael A Tuke
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

4.  Wear testing of a DJOA finger prosthesis in vitro.

Authors:  Thomas J Joyce
Journal:  J Mater Sci Mater Med       Date:  2010-02-11       Impact factor: 3.896

Review 5.  Biotribology of artificial hip joints.

Authors:  Francesca Di Puccio; Lorenza Mattei
Journal:  World J Orthop       Date:  2015-01-18

Review 6.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18

7.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

8.  Retrieval analysis of alumina ceramic-on-ceramic bearing couples.

Authors:  Muhammad Korim; Susan Scholes; Anthony Unsworth; Richard Power
Journal:  Acta Orthop       Date:  2014-04       Impact factor: 3.717

9.  Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.

Authors:  Philipp Damm; Alwina Bender; Georg Bergmann
Journal:  PLoS One       Date:  2015-03-25       Impact factor: 3.240

10.  Friction in total hip joint prosthesis measured in vivo during walking.

Authors:  Philipp Damm; Joern Dymke; Robert Ackermann; Alwina Bender; Friedmar Graichen; Andreas Halder; Alexander Beier; Georg Bergmann
Journal:  PLoS One       Date:  2013-11-08       Impact factor: 3.240