Literature DB >> 11255185

Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape.

I Catelas1, J D Bobyn, J B Medley, J J Krygier, D J Zukor, A Petit, O L Huk.   

Abstract

Isolation of metal wear particles from hip simulator lubricants or tissues surrounding implants is a challenging problem because of small particle size, their tendency to agglomerate, and their potential for chemical degradation by digestion reagents. To provide realistic measurements of size, shape, and composition of metal wear particles, it is important to optimize particle isolation and minimize particle changes due to the effects of the reagents. In this study (Part I of II), transmission electron microscopy (TEM) was used to examine and compare the effects of different isolation protocols, using enzymes or alkaline solutions, on the size and shape of three different types of cobalt-based alloy particles produced from metal-metal bearings. The effect on particle composition was examined in a subsequent study (Part II). Large particles (<1200 nm) were generated by dry abrasion of CoCrMo alloy against itself and small particles (<300 nm) were generated by hip simulator testing of a metal-metal implant pair in the presence of either distilled-deionized water or a 95% bovine serum solution. The reagents changed particle size and to a lesser extent particle shape. For both large particles and small particles generated in water, the changes in size were more extensive after alkaline than after enzymatic protocols and increased with alkaline concentration and time in solution, up to twofold at 2 h and threefold at 48 h. However, when isolating particles from 95% serum, an initial protective effect of serum proteins and/or lipids was observed. Because of this protective effect, there was no significant difference in particle size and shape for both oval and needle-shaped particles after 2 h in 2N KOH and after enzymatic treatments. However, round particles were significantly smaller after 2 h in 2N KOH than after enzymatic treatments. Particle composition may also have been affected by the 2N KOH treatment, as suggested by a difference in particle contrast under TEM, an issue examined in detail in Part II. Copyright 2001 John Wiley & Sons, Inc. J Biomed Mater Res 55: 320-329, 2001

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11255185     DOI: 10.1002/1097-4636(20010605)55:3<320::aid-jbm1020>3.0.co;2-3

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  18 in total

1.  The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Harry McKellop; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test.

Authors:  Fang Lu; Matt Royle; Ferdinand V Lali; Alister J Hart; Simon Collins; Jonathan Housden; Julia C Shelton
Journal:  J Mater Sci Mater Med       Date:  2012-03-06       Impact factor: 3.896

Review 3.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

Review 4.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

5.  Characterization of Wear Particles Generated from CoCrMo Alloy under Sliding Wear Conditions.

Authors:  R Pourzal; I Catelas; R Theissmann; C Kaddick; A Fischer
Journal:  Wear       Date:  2011-07-29       Impact factor: 3.892

6.  Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients.

Authors:  Songyun Liu; Deborah J Hall; Stephanie M McCarthy; Joshua J Jacobs; Robert M Urban; Robin Pourzal
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2019-05-17       Impact factor: 3.368

7.  Comparison of periprosthetic tissue digestion methods for ultra-high molecular weight polyethylene wear debris extraction.

Authors:  Ryan M Baxter; Marla J Steinbeck; Joanne L Tipper; Javad Parvizi; Michele Marcolongo; Steve M Kurtz
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-10       Impact factor: 3.368

Review 8.  Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

Authors:  Divya Rani Bijukumar; Abhijith Segu; Júlio C M Souza; XueJun Li; Mark Barba; Louis G Mercuri; Joshua J Jacobs; Mathew Thoppil Mathew
Journal:  Nanomedicine       Date:  2018-01-12       Impact factor: 5.307

9.  Differential toxicity of processed and non-processed states of CoCrMo degradation products generated from a hip simulator on neural cells.

Authors:  Divya Rani Bijukumar; Abhijith Segu; YongChao Mou; Reza Ghodsi; Tolou Shokufhar; Mark Barba; Xue-Jun Li; Mathew Thoppil Mathew
Journal:  Nanotoxicology       Date:  2018-09-25       Impact factor: 5.913

10.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.