Off-resonance-robust velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.

Taehoon Shin1, Bob S Hu, Dwight G Nishimura.   

Abstract

PURPOSE: To develop a new velocity-selective (VS) excitation pulse sequence which is robust to field inhomogeneity, and demonstrate its application to non-contrast-enhanced peripheral MR angiography (MRA).
METHODS: The off-resonance-robust VS saturation pulse is designed by incorporating 180° refocusing pulses into the k-space-based reference design and tailoring sequence parameters in a velocity region of interest. The VS saturation pulse is used as magnetization preparation for non-contrast-enhanced peripheral MRA to suppress background tissues but not arterial blood based on their velocities. Non-contrast-enhanced peripheral MRA using the proposed VS preparation was tested in healthy volunteers and a patient with arterial stenosis.
RESULTS: Calf angiograms obtained using the new VS preparation show more uniform background suppression than the reference VS preparation, as demonstrated by larger mean values and smaller standard deviations of artery-to-vein and artery-to-muscle contrast-to-noise ratios (71.0 ± 11.4 and 75.3 ± 12.1 versus 61.7 ± 22.7 and 58.5 ± 27.8). Two-station peripheral MRA using the new VS preparation identifies stenosis of the femoral and popliteal arteries in the patient, as validated by digital subtraction angiography.
CONCLUSION: Non-contrast-enhanced MRA using the new VS magnetization preparation can reliably provide high angiographic contrast in the lower extremities with significantly improved immunity to field inhomogeneity.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  magnetization preparation; non-contrast-enhanced MRA; peripheral MRA; velocity-selective excitation

Mesh:

Substances:

Year:  2012        PMID: 23192893      PMCID: PMC3594489          DOI: 10.1002/mrm.24561

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  Triggered real-time MRI and cardiac applications.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  MR angiography with adiabatic flow excitation.

Authors:  J N Lee; D L Parker
Journal:  J Magn Reson Imaging       Date:  1992 Jul-Aug       Impact factor: 4.813

4.  Coronary MR angiography at 3T during diastole and systole.

Authors:  Ahmed M Gharib; Daniel A Herzka; Ali O Ustun; Milind Y Desai; Julia Locklin; Roderic I Pettigrew; Matthias Stuber
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

5.  NMR velocity-selective excitation composites for flow and motion imaging and suppression of static tissue signal.

Authors:  P R Moran; D Saloner; B W Tsui
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

6.  Non-contrast-enhanced vascular magnetic resonance imaging using flow-dependent preparation with subtraction.

Authors:  Andrew N Priest; Martin J Graves; David J Lomas
Journal:  Magn Reson Med       Date:  2011-06-28       Impact factor: 4.668

7.  Non-contrast-enhanced renal and abdominal MR angiography using velocity-selective inversion preparation.

Authors:  Taehoon Shin; Pauline W Worters; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-06-18       Impact factor: 4.668

8.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

9.  Multicenter trial to evaluate vascular magnetic resonance angiography of the lower extremity. American College of Radiology Rapid Technology Assessment Group.

Authors:  R A Baum; C M Rutter; J H Sunshine; J S Blebea; J Blebea; J P Carpenter; K W Dickey; S F Quinn; A S Gomes; T M Grist
Journal:  JAMA       Date:  1995-09-20       Impact factor: 56.272

10.  MR gated subtraction angiography: evaluation of lower extremities.

Authors:  R A Meuli; V J Wedeen; S C Geller; R R Edelman; L R Frank; T J Brady; B R Rosen
Journal:  Radiology       Date:  1986-05       Impact factor: 11.105

View more
  19 in total

Review 1.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

2.  Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains.

Authors:  Qin Qin; Yaoming Qu; Wenbo Li; Dapeng Liu; Taehoon Shin; Yansong Zhao; Doris D Lin; Peter C M van Zijl; Zhibo Wen
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

3.  Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Authors:  Dan Zhu; Wenbo Li; Dapeng Liu; Guanshu Liu; Yigang Pei; Taehoon Shin; Farzad Sedaghat; Qin Qin
Journal:  Magn Reson Med       Date:  2020-02-04       Impact factor: 4.668

4.  Near-isotropic noncontrast MRA of the renal and peripheral arteries using a thin-slab stack-of-stars quiescent interval slice-selective acquisition.

Authors:  Robert R Edelman; Emily Aherne; Nondas Leloudas; Jianing Pang; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

5.  Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity.

Authors:  Qin Qin; Taehoon Shin; Michael Schär; Hua Guo; Hanwei Chen; Ye Qiao
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

6.  Characterization and suppression of stripe artifact in velocity-selective magnetization-prepared unenhanced MR angiography.

Authors:  Taehoon Shin; Qin Qin
Journal:  Magn Reson Med       Date:  2018-03-13       Impact factor: 4.668

7.  Improved acceleration of phase-contrast flow imaging with magnitude difference regularization.

Authors:  Taehoon Shin; Wanyong Shin
Journal:  Magn Reson Imaging       Date:  2019-12-02       Impact factor: 2.546

8.  Identification and reduction of image artifacts in non-contrast-enhanced velocity-selective peripheral angiography at 3T.

Authors:  Taehoon Shin; Qin Qin; Jang-Yeon Park; Robert S Crawford; Sanjay Rajagopalan
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

9.  Improved velocity-selective labeling pulses for myocardial ASL.

Authors:  Vanessa Landes; Ahsan Javed; Terrence Jao; Qin Qin; Krishna Nayak
Journal:  Magn Reson Med       Date:  2020-03-15       Impact factor: 4.668

10.  Non-contrast-enhanced peripheral angiography using a sliding interleaved cylinder acquisition.

Authors:  Kie Tae Kwon; Adam B Kerr; Holden H Wu; Bob S Hu; Jean H Brittain; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.