Literature DB >> 23144437

The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery.

Yong-Hee Park1, Ji-Hyun Lee, Hyun-Gul Song, Hyo-Jin Byon, Hee-Soo Kim, Jin-Tae Kim.   

Abstract

BACKGROUND: The most common method for determining the hemoglobin concentration is to draw blood from a patient. However, the Radical-7 Pulse CO-Oximeter (Masimo Corporation, Irvine, CA) can noninvasively provide continuous hemoglobin concentration (SpHb). In our study we compared noninvasive measurements of SpHb with simultaneous laboratory measurements of total hemoglobin in arterial blood samples taken from children (tHb).
METHODS: Arterial blood samples were analyzed using a laboratory CO-oximeter, and SpHb was simultaneously recorded in pediatric patients undergoing neurosurgery. When patients met the criteria for hypovolemia, 10 mL/kg of colloids or red blood cells were administered over 10 minutes. SpHb and tHb data were collected before and after intravascular volume resuscitation. The relationship between SpHb and tHb was assessed using a 4-quadrant plot, linear regression, mixed-effect model, and modified Bland-Altman analyses.
RESULTS: One hundred nineteen paired samples were analyzed. The correlation coefficient between SpHb and tHb was 0.53 (P < 0.001), whereas that of change in SpHb versus change in tHb was 0.75 (P < 0.001). The average difference (bias) between tHb and SpHb was 0.90 g/dL (95% confidence interval [CI], 0.48-1.32 g/dL) and 1 standard deviation of the difference (sd) was 1.35 g/dL. The concordance rate (a measure of the number of data points that are in 1 of the 2 quadrants of agreement) determined using a 4-quadrant plot was 93%. The correlation coefficient between SpHb and tHb after intravascular volume resuscitation was 0.58 (P < 0.001), whereas that of changes in SpHb and tHb was 0.87 (P < 0.001). The bias immediately after volume resuscitation was 1.18 g/dL (95% CI, 0.81-1.55 g/dL), and sd was 1.28 g/dL with a concordance rate of 94.4%. The bias was -0.03 g/dL when tHb was ≥11 g/dL, which was significantly lower in comparison with biases when tHb <9 g/dL (1.24 g/dL) and tHb was 9-11 g/dL (1.17 g/dL) (P = 0.004).
CONCLUSION: The Radical-7 Pulse CO-Oximeter can be useful as a trend monitor in children during surgery even immediately after intravascular volume expanders are administered. However, it is advisable to confirm the baseline hemoglobin level and to consider the influence of tHb level on the bias. In addition, one should be cautious with regard to using SpHb alone when making transfusion decisions.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23144437     DOI: 10.1213/ANE.0b013e31826b7e38

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  14 in total

1.  A noninvasive hemoglobin monitor in the pediatric intensive care unit.

Authors:  Michael R Phillips; Amal L Khoury; Andrey V Bortsov; Amy Marzinsky; Kathy A Short; Bruce A Cairns; Anthony G Charles; Benny L Joyner; Sean E McLean
Journal:  J Surg Res       Date:  2015-01-09       Impact factor: 2.192

2.  Evaluation of multiwave pulse total-hemoglobinometer during general anesthesia.

Authors:  Daisuke Toyoda; Rie Yasumura; Mitsue Fukuda; Ryoichi Ochiai; Yoshifumi Kotake
Journal:  J Anesth       Date:  2013-10-22       Impact factor: 2.078

3.  Comparison of the accuracy of noninvasive hemoglobin monitoring for preoperative evaluation between adult and pediatric patients: a retrospective study.

Authors:  Yong-Hee Park; Seho Lim; Hyun Kang; Hwa-Yong Shin; Chong Wha Baek; Young Cheol Woo
Journal:  J Clin Monit Comput       Date:  2018-01-04       Impact factor: 2.502

4.  Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis.

Authors:  Hosein Shabaninejad; Nashmil Ghadimi; Kourosh Sayehmiri; Hossein Hosseinifard; Rasoul Azarfarin; Hasan Abolghasem Gorji
Journal:  J Anesth       Date:  2019-03-20       Impact factor: 2.078

5.  Non-invasive prediction of hemoglobin levels by principal component and back propagation artificial neural network.

Authors:  Haiquan Ding; Qipeng Lu; Hongzhi Gao; Zhongqi Peng
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

6.  Noninvasively Measured Hemoglobin Concentration Reflects Arterial Hemoglobin Concentration Before but Not After Cardiopulmonary Bypass in Patients Undergoing Coronary Artery or Valve Surgery.

Authors:  Matthias L Riess; Paul S Pagel
Journal:  J Cardiothorac Vasc Anesth       Date:  2016-03-24       Impact factor: 2.628

7.  Validation of noninvasive hemoglobin measurement by pulse co-oximeter in newborn infants.

Authors:  C Nicholas; R George; S Sardesai; M Durand; R Ramanathan; R Cayabyab
Journal:  J Perinatol       Date:  2015-03-05       Impact factor: 2.521

8.  The use of a noninvasive hemoglobin monitor for determining fluid distribution and elimination in pediatric patients undergoing minor surgery.

Authors:  Qingquan Lian; Husong Li; Ruifeng Zeng; Junhui Lang; Wangning Shangguan; Huacheng Liu; Benfu Wang; Peter M Rodhe; Christer H Svensen
Journal:  J Clin Monit Comput       Date:  2014-02-19       Impact factor: 2.502

9.  Evaluation of a Noninvasive Hemoglobin Measurement Device to Screen for Anemia in Infancy.

Authors:  Daniel P Hsu; Alicia J French; Samuel L Madson; John M Palmer; Vinod Gidvani-Diaz
Journal:  Matern Child Health J       Date:  2016-04

10.  Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery.

Authors:  Naveen Selvaraj; Gaurav Jain; Debendra Kumar Tripathy; Ankur Mittal; Haritha Indulekha
Journal:  Indian J Anaesth       Date:  2021-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.