Literature DB >> 24146037

Evaluation of multiwave pulse total-hemoglobinometer during general anesthesia.

Daisuke Toyoda1, Rie Yasumura, Mitsue Fukuda, Ryoichi Ochiai, Yoshifumi Kotake.   

Abstract

The purpose of this prospective study was to evaluate the accuracy and trending ability of a four-wavelength pulse-total hemoglobinometer that continuously and noninvasively measures hemoglobin in surgical patients. With IRB approval and informed consent, spectrophotometric hemoglobin (SpHb) was measured with a pulse-total hemoglobinometer manufactured by Nihon Kohden Corp (Tokyo, Japan) and compared to the CO-oximeter equipped with blood gas analyzer. Two hundred twenty-five samples from 56 subjects underwent analysis. Bland-Altman analysis revealed that the bias ± precision of the current technology was 0.0 ± 1.4 g/dl and -0.2 ± 1.3 g/dl for total samples and samples with 8 < Hb < 11 g/dl, respectively. The percentages of samples with intermediate risk of therapeutic error in error grid analysis and the concordance rate of 4-quadrant trending assay was 17 % and 77 %, respectively. The Cohen kappa statistic for Hb < 10 g/dl was 0.38, suggesting that the agreement between SpHb and CO-oximeter-derived Hb was fair. Collectively, wide limits of agreement, especially at the critical level of hemoglobin, and less than moderate agreement against CO-oximeter-derived hemoglobin preclude the use of the pulse-total hemoglobinometer as a decision-making tool for transfusion.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24146037     DOI: 10.1007/s00540-013-1730-5

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  21 in total

1.  Liberal or restrictive transfusion in high-risk patients after hip surgery.

Authors:  Jeffrey L Carson; Michael L Terrin; Helaine Noveck; David W Sanders; Bernard R Chaitman; George G Rhoads; George Nemo; Karen Dragert; Lauren Beaupre; Kevin Hildebrand; William Macaulay; Courtland Lewis; Donald Richard Cook; Gwendolyn Dobbin; Khwaja J Zakriya; Fred S Apple; Rebecca A Horney; Jay Magaziner
Journal:  N Engl J Med       Date:  2011-12-14       Impact factor: 91.245

2.  Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers.

Authors:  Volkher Scharnhorst; Petra J Van De Laar; Huib L Vader
Journal:  Clin Chem       Date:  2003-12       Impact factor: 8.327

3.  Intravenous fluids cause systemic bias in a conductivity-based point-of-care hematocrit meter.

Authors:  Patrick Wu; Timothy E Morey; Neil S Harris; Nikolaus Gravenstein; Mark J Rice
Journal:  Anesth Analg       Date:  2011-12-09       Impact factor: 5.108

Review 4.  The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration.

Authors:  Micha Y Shamir; Aharon Avramovich; Todd Smaka
Journal:  Anesth Analg       Date:  2011-09-29       Impact factor: 5.108

5.  The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery.

Authors:  Ba-Vinh Nguyen; Jean-Louis Vincent; Emmanuel Nowak; Michelle Coat; Nicolas Paleiron; Pierre Gouny; Mehdi Ould-Ahmed; Maité Guillouet; Charles Christian Arvieux; Gildas Gueret
Journal:  Anesth Analg       Date:  2011-09-14       Impact factor: 5.108

6.  Is a low transfusion threshold safe in critically ill patients with cardiovascular diseases?

Authors:  P C Hébert; E Yetisir; C Martin; M A Blajchman; G Wells; J Marshall; M Tweeddale; G Pagliarello; I Schweitzer
Journal:  Crit Care Med       Date:  2001-02       Impact factor: 7.598

7.  The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery.

Authors:  Yong-Hee Park; Ji-Hyun Lee; Hyun-Gul Song; Hyo-Jin Byon; Hee-Soo Kim; Jin-Tae Kim
Journal:  Anesth Analg       Date:  2012-11-09       Impact factor: 5.108

8.  Pulse total-hemoglobinometer provides accurate noninvasive monitoring.

Authors:  Eisei Noiri; Naoki Kobayashi; Yoshiaki Takamura; Takehiko Iijima; Toshiyuki Takagi; Kent Doi; Akihide Nakao; Tokunori Yamamoto; Sunao Takeda; Toshiro Fujita
Journal:  Crit Care Med       Date:  2005-12       Impact factor: 7.598

9.  Perioperative red cell, plasma, and blood volume change in patients undergoing cardiac surgery.

Authors:  Robert D Slight; Norzeihan J Bappu; Onyekwelu C Nzewi; D Brian L McClelland; Pankaj S Mankad
Journal:  Transfusion       Date:  2006-03       Impact factor: 3.157

10.  Central, peripheral, and other blood volume changes during hemodialysis.

Authors:  Suma Prakash; Donal Reddan; A Paul Heidenheim; Cynthia Kianfar; Robert M Lindsay
Journal:  ASAIO J       Date:  2002 Jul-Aug       Impact factor: 2.872

View more
  2 in total

1.  Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis.

Authors:  Hosein Shabaninejad; Nashmil Ghadimi; Kourosh Sayehmiri; Hossein Hosseinifard; Rasoul Azarfarin; Hasan Abolghasem Gorji
Journal:  J Anesth       Date:  2019-03-20       Impact factor: 2.078

2.  Meta-analytic estimation of measurement variability and assessment of its impact on decision-making: the case of perioperative haemoglobin concentration monitoring.

Authors:  Emmanuel Charpentier; Vincent Looten; Björn Fahlgren; Alexandre Barna; Loïc Guillevin
Journal:  BMC Med Res Methodol       Date:  2016-01-19       Impact factor: 4.615

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.