Literature DB >> 24761296

Non-invasive prediction of hemoglobin levels by principal component and back propagation artificial neural network.

Haiquan Ding1, Qipeng Lu1, Hongzhi Gao1, Zhongqi Peng1.   

Abstract

To facilitate non-invasive diagnosis of anemia, specific equipment was developed, and non-invasive hemoglobin (HB) detection method based on back propagation artificial neural network (BP-ANN) was studied. In this paper, we combined a broadband light source composed of 9 LEDs with grating spectrograph and Si photodiode array, and then developed a high-performance spectrophotometric system. By using this equipment, fingertip spectra of 109 volunteers were measured. In order to deduct the interference of redundant data, principal component analysis (PCA) was applied to reduce the dimensionality of collected spectra. Then the principal components of the spectra were taken as input of BP-ANN model. On this basis we obtained the optimal network structure, in which node numbers of input layer, hidden layer, and output layer was 9, 11, and 1. Calibration and correction sample sets were used for analyzing the accuracy of non-invasive hemoglobin measurement, and prediction sample set was used for testing the adaptability of the model. The correlation coefficient of network model established by this method is 0.94, standard error of calibration, correction, and prediction are 11.29g/L, 11.47g/L, and 11.01g/L respectively. The result proves that there exist good correlations between spectra of three sample sets and actual hemoglobin level, and the model has a good robustness. It is indicated that the developed spectrophotometric system has potential for the non-invasive detection of HB levels with the method of BP-ANN combined with PCA.

Entities:  

Keywords:  (070.4790) Spectrum analysis; (170.1470) Blood or tissue constituent monitoring

Year:  2014        PMID: 24761296      PMCID: PMC3985987          DOI: 10.1364/BOE.5.001145

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  8 in total

1.  Noninvasive glucose sensing.

Authors:  Mark A Arnold; Gary W Small
Journal:  Anal Chem       Date:  2005-09-01       Impact factor: 6.986

2.  Pulse glucometry: A new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry.

Authors:  K Yamakoshi; Y Yamakoshi
Journal:  J Biomed Opt       Date:  2006 Sep-Oct       Impact factor: 3.170

3.  The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery.

Authors:  Yong-Hee Park; Ji-Hyun Lee; Hyun-Gul Song; Hyo-Jin Byon; Hee-Soo Kim; Jin-Tae Kim
Journal:  Anesth Analg       Date:  2012-11-09       Impact factor: 5.108

4.  Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement.

Authors:  Lionel Lamhaut; Roxana Apriotesei; Xavier Combes; Marc Lejay; Pierre Carli; Benoît Vivien
Journal:  Anesthesiology       Date:  2011-09       Impact factor: 7.892

5.  Non-invasive monitoring of haemoglobin concentration in paediatric surgical patients using near-infrared spectroscopy.

Authors:  A Dullenkopf; U Lohmeyer; B Salgo; A C Gerber; M Weiss
Journal:  Anaesthesia       Date:  2004-05       Impact factor: 6.955

6.  Noninvasive monitoring of hemoglobin. The effects of WBC counts on measurement.

Authors:  Katsuyasu Saigo; Shion Imoto; Makoto Hashimoto; Hisashi Mito; Junko Moriya; Tadanobu Chinzei; Yoshitsugu Kubota; Shigehiro Numada; Toshiyuki Ozawa; Shunichi Kumagai
Journal:  Am J Clin Pathol       Date:  2004-01       Impact factor: 2.493

7.  Visible and near-infrared spectral changes in the thumb of patients with chronic fatigue syndrome.

Authors:  Akikazu Sakudo; Yukiko Hakariya Kato; Seiki Tajima; Hirohiko Kuratsune; Kazuyoshi Ikuta
Journal:  Clin Chim Acta       Date:  2009-02-25       Impact factor: 3.786

8.  Accuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer.

Authors:  N Shah; E A Osea; G J Martinez
Journal:  Int J Lab Hematol       Date:  2013-06-27       Impact factor: 2.877

  8 in total
  4 in total

Review 1.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

2.  Assessment of triglyceride and cholesterol in overweight people based on multiple linear regression and artificial intelligence model.

Authors:  Jing Ma; Jiong Yu; Guangshu Hao; Dan Wang; Yanni Sun; Jianxin Lu; Hongcui Cao; Feiyan Lin
Journal:  Lipids Health Dis       Date:  2017-02-20       Impact factor: 3.876

3.  Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations.

Authors:  Md Kamrul Hasan; Md Hasanul Aziz; Md Ishrak Islam Zarif; Mahmudul Hasan; Mma Hashem; Shion Guha; Richard R Love; Sheikh Ahamed
Journal:  JMIR Mhealth Uhealth       Date:  2021-04-08       Impact factor: 4.773

4.  Identification of Signature Genes and Construction of an Artificial Neural Network Model of Prostate Cancer.

Authors:  Hongye Dong; Xu Wang
Journal:  J Healthc Eng       Date:  2022-04-07       Impact factor: 3.822

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.