In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX.

Fernando Accorsi Orosco1, Norberti Bernardineli, Roberto Brandão Garcia, Clovis Monteiro Bramante, Marco Antonio Húngaro Duarte, Ivaldo Gomes de Moraes.   

Abstract

OBJECTIVES: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length.
MATERIAL AND METHODS: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex.
RESULTS: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05).
CONCLUSIONS: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.

Entities:  

Mesh:

Year:  2012        PMID: 23138737      PMCID: PMC3881798          DOI: 10.1590/s1678-77572012000500005

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  18 in total

1.  Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography.

Authors:  E Borg; A Attaelmanan; H G Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  2000-03       Impact factor: 2.419

2.  A comparison of phosphor-plate digital images with conventional radiographs for the perceived clarity of fine endodontic files and periapical lesions.

Authors:  Lara T Friedlander; Robert M Love; Nicholas P Chandler
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2002-03

3.  Working length determination in palatal roots of maxillary molars.

Authors:  Melanie A Kim-Park; Linda W Baughan; Gary R Hartwell
Journal:  J Endod       Date:  2003-01       Impact factor: 4.171

4.  Radiovisiography for imaging root canals: an in vitro comparison with conventional radiography.

Authors:  A C Shearer; K Horner; N H Wilson
Journal:  Quintessence Int       Date:  1990-10       Impact factor: 1.677

5.  Radiovisiography versus conventional radiography for detection of small instruments in endodontic length determination. Part 1. In vitro evaluation.

Authors:  M A Ellingsen; G W Harrington; L G Hollender
Journal:  J Endod       Date:  1995-06       Impact factor: 4.171

6.  Evaluation of a digital radiography to estimate working length.

Authors:  A Almenar García; L Forner Navarro; V Ubet Castelló; R Miñana Laliga
Journal:  J Endod       Date:  1997-06       Impact factor: 4.171

7.  Endodontic working length assessment. Comparison of storage phosphor digital imaging and radiographic film.

Authors:  R A Cederberg; E Tidwell; N L Frederiksen; B W Benson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-03

8.  Comparison of a photostimulable phosphor system with film for dental radiology.

Authors:  W Huda; L N Rill; D K Benn; J C Pettigrew
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1997-06

9.  Comparison of radiographic and electronic working lengths.

Authors:  D H Pratten; N J McDonald
Journal:  J Endod       Date:  1996-04       Impact factor: 4.171

10.  Image quality of direct digital intraoral x-ray sensors in assessing root canal length. The RadioVisioGraphy, Visualix/VIXA, Sens-A-Ray, and Flash Dent systems compared with Ektaspeed films.

Authors:  G C Sanderink; R Huiskens; P F van der Stelt; U S Welander; S E Stheeman
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1994-07
View more
  3 in total

1.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

2.  Comparison of Tentative Radiographic Working Length with and without grid Versus Electronic Apex Locator.

Authors:  Tanikonda Rambabu; Visinigiri Srikanth; Girija S Sajjan; Sirisha Ganguru; Chava Gayatri; K Roja
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar

Review 3.  Accuracy of different generations of apex locators in determining working length; a systematic review and meta-analysis.

Authors:  Kaveh Nasiri; Karl-Thomas Wrbas
Journal:  Saudi Dent J       Date:  2021-09-25