Literature DB >> 9580242

Evaluation of a digital radiography to estimate working length.

A Almenar García1, L Forner Navarro, V Ubet Castelló, R Miñana Laliga.   

Abstract

The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulted in an impression of a shortened image of about 1.5 mm when using the indirect methods (significance level: alpha = 0.05).

Entities:  

Mesh:

Year:  1997        PMID: 9580242     DOI: 10.1016/s0099-2399(97)80183-5

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  The accuracy of digital radiography in orthopaedic applications.

Authors:  John R Fowler; Asif M Ilyas
Journal:  Clin Orthop Relat Res       Date:  2010-10-23       Impact factor: 4.176

2.  Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment.

Authors:  Ligia Buloto Schmitd; Tatiana de Castro Lima; Luiz Eduardo Montenegro Chinellato; Clóvis Monteiro Bramante; Roberto Brandão Garcia; Ivaldo Gomes de Moraes; Norberti Bernardineli
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

3.  In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX.

Authors:  Fernando Accorsi Orosco; Norberti Bernardineli; Roberto Brandão Garcia; Clovis Monteiro Bramante; Marco Antonio Húngaro Duarte; Ivaldo Gomes de Moraes
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

4.  A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study.

Authors:  Irfana Khursheed; Ruchika Bansal; Tajinder Bansal; Harkanwal Preet Singh; Madhulika Yadav; K Jetender Reddy
Journal:  Dent Res J (Isfahan)       Date:  2014-01

5.  An in vitro stereomicroscopic comparative evaluation of a combination of apex locator and endodontic motor with an integrated endodontic motor.

Authors:  Ch Swarupa; Girija S Sajjan; Yv Sashi Kanth
Journal:  J Conserv Dent       Date:  2013-09

6.  Effect of digital noise reduction on the accuracy of endodontic file length determination.

Authors:  Mojdeh Mehdizadeh; Abbas Ali Khademi; Ali Shokraneh; Nastaran Farhadi
Journal:  Imaging Sci Dent       Date:  2013-09-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.