Abstract

The Trophy RadioVisioGraphy model 32000 system in Normal Mode, the Trophy RVG-PC in Normal and Archive Mode, the Gendex VIXA/Visualix, the Regam Sens-A-Ray, and the Villa Flash Dent in High-Resolution Mode and Normal Mode were compared with respect to the visibility of endodontic files. Kodak Ektaspeed film served as the reference. An acrylic embedded human skull was prepared for taking radiographs with endodontic files (Kerr files size 10 and size 15) on full root length and 1.5 mm short in upper and lower premolars and molars. Possibilities for enhancement of the digital images were not studied. Receiver operating characteristics curves were derived and the areas under the curves were averaged and compared using Student's t test statistic (p < 0.05). Kodak Ektaspeed film gave acceptable results for both file sizes. Both Trophy RVG units in Normal Mode and the Regam Sens-A-Ray system gave results above the areas under the curves equals 0.95 for the size 15 files. For the size 10 files the values of the areas under the curves of all sensors systems were below this threshold. It is concluded that both RVG units in Normal Mode and the Sens-A-Ray system render a comparable result with conventional radiography in determining root canal length with the use of a size 15 files. All sensor systems were unacceptably inferior to film images when size 10 files were used.

Entities:  

Mesh:

Year:  1994        PMID: 8078654     DOI: 10.1016/0030-4220(94)90128-7

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  7 in total

1.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

2.  Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment.

Authors:  Ligia Buloto Schmitd; Tatiana de Castro Lima; Luiz Eduardo Montenegro Chinellato; Clóvis Monteiro Bramante; Roberto Brandão Garcia; Ivaldo Gomes de Moraes; Norberti Bernardineli
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

3.  Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions.

Authors:  Jun-Ge Cheng; Zhi-Ling Zhang; Xiao-Yan Wang; Zu-Yan Zhang; Xu-Chen Ma; Gang Li
Journal:  Clin Oral Investig       Date:  2011-07-30       Impact factor: 3.573

4.  In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX.

Authors:  Fernando Accorsi Orosco; Norberti Bernardineli; Roberto Brandão Garcia; Clovis Monteiro Bramante; Marco Antonio Húngaro Duarte; Ivaldo Gomes de Moraes
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

5.  Image quality evaluation of eight complementary metal-oxide semiconductor intraoral digital X-ray sensors.

Authors:  Sorin Teich; Wisam Al-Rawi; Masahiro Heima; Fady F Faddoul; Gil Goldzweig; Zvi Gutmacher; Dror Aizenbud
Journal:  Int Dent J       Date:  2016-04-22       Impact factor: 2.607

6.  Accuracy of Digital Bitewing Radiography versus Different Views of Digital Panoramic Radiography for Detection of Proximal Caries.

Authors:  Mehrdad Abdinian; Sayed Mohammad Razavi; Reyhaneh Faghihian; Amir Abbas Samety; Elham Faghihian
Journal:  J Dent (Tehran)       Date:  2015-04

7.  Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study.

Authors:  Mohammad Mahdi Yaghooti Khorasani; Hamed Ebrahimnejad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.