Literature DB >> 23127077

Toward quantifying the composition of soft tissues by spectral CT with Medipix3.

J Paul Ronaldson1, Rafidah Zainon, Nicola Jean Agnes Scott, Steven Paul Gieseg, Anthony P Butler, Philip H Butler, Nigel G Anderson.   

Abstract

PURPOSE: To determine the potential of spectral computed tomography (CT) with Medipix3 for quantifying fat, calcium, and iron in soft tissues within small animal models and surgical specimens of diseases such as fatty liver (metabolic syndrome) and unstable atherosclerosis.
METHODS: The spectroscopic method was applied to tomographic data acquired using a micro-CT system incorporating a Medipix3 detector array with silicon sensor layer and microfocus x-ray tube operating at 50 kVp. A 10 mm diameter perspex phantom containing a fat surrogate (sunflower oil) and aqueous solutions of ferric nitrate, calcium chloride, and iodine was imaged with multiple energy bins. The authors used the spectroscopic characteristics of the CT number to establish a basis for the decomposition of soft tissue components. The potential of the method of constrained least squares for quantifying different sets of materials was evaluated in terms of information entropy and degrees of freedom, with and without the use of a volume conservation constraint. The measurement performance was evaluated quantitatively using atheroma and mouse equivalent phantoms. Finally the decomposition method was assessed qualitatively using a euthanized mouse and an excised human atherosclerotic plaque.
RESULTS: Spectral CT measurements of a phantom containing tissue surrogates confirmed the ability to distinguish these materials by the spectroscopic characteristics of their CT number. The assessment of performance potential in terms of information entropy and degrees of freedom indicated that certain sets of up to three materials could be decomposed by the method of constrained least squares. However, there was insufficient information within the data set to distinguish calcium from iron within soft tissues. The quantification of calcium concentration and fat mass fraction within atheroma and mouse equivalent phantoms by spectral CT correlated well with the nominal values (R(2) = 0.990 and R(2) = 0.985, respectively). In the euthanized mouse and excised human atherosclerotic plaque, regions of calcium and fat were appropriately decomposed according to their spectroscopic characteristics.
CONCLUSIONS: Spectral CT, using the Medipix3 detector and silicon sensor layer, can quantify certain sets of up to three materials using the proposed method of constrained least squares. The system has some ability to independently distinguish calcium, fat, and water, and these have been quantified within phantom equivalents of fatty liver and atheroma. In this configuration, spectral CT cannot distinguish iron from calcium within soft tissues.

Entities:  

Mesh:

Year:  2012        PMID: 23127077     DOI: 10.1118/1.4760773

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

2.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

3.  Quantitative imaging of excised osteoarthritic cartilage using spectral CT.

Authors:  Kishore Rajendran; Caroline Löbker; Benjamin S Schon; Christopher J Bateman; Raja Aamir Younis; Niels J A de Ruiter; Alex I Chernoglazov; Mohsen Ramyar; Gary J Hooper; Anthony P H Butler; Tim B F Woodfield; Nigel G Anderson
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

Review 4.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Authors:  Shuai Leng; Michael Bruesewitz; Shengzhen Tao; Kishore Rajendran; Ahmed F Halaweish; Norbert G Campeau; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiographics       Date:  2019 May-Jun       Impact factor: 5.333

Review 5.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

6.  A framework for performance characterization of energy-resolving photon-counting detectors.

Authors:  Mats Persson; Paurakh L Rajbhandary; Norbert J Pelc
Journal:  Med Phys       Date:  2018-10-12       Impact factor: 4.071

Review 7.  Cardiac CT Imaging of Plaque Vulnerability: Hype or Hope?

Authors:  Martin J Willemink; Tim Leiner; Pál Maurovich-Horvat
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

8.  Optimization of K-edge imaging for vulnerable plaques using gold nanoparticles and energy resolved photon counting detectors: a simulation study.

Authors:  Yahya Alivov; Pavlo Baturin; Huy Q Le; Justin Ducote; Sabee Molloi
Journal:  Phys Med Biol       Date:  2013-12-13       Impact factor: 3.609

9.  Detection of increased vasa vasorum in artery walls: Improving CT number accuracy using image deconvolution.

Authors:  Kishore Rajendran; Shuai Leng; Steven M Jorgensen; Dilbar Abdurakhimova; Erik L Ritman; Cynthia H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

10.  Image-based Material Decomposition with a General Volume Constraint for Photon-Counting CT.

Authors:  Zhoubo Li; Shuai Leng; Lifeng Yu; Zhicong Yu; Cynthia H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.