Abstract

Photon-counting CT (PCCT) potentially offers both improved dose efficiency and material decomposition capabilities relative to CT systems using energy integrating detectors. With respect to material decomposition, both projection-based and image-based methods have been proposed, most of which require accurate a priori information regarding the shape of the x-ray spectra and the response of the detectors. Additionally, projection-based methods require access to projection data. These data can be difficult to obtain, since spectra, detector response, and projection data formats are proprietary information. Further, some published image-based, 3-material decomposition methods require a volume conservation assumption, which is often violated in solutions. We have developed an image-based material decomposition method that can overcome those limitations. We introduced a general condition on volume constraint that does not require the volume to be conserved in a mixture. An empirical calibration can be performed with various concentrations of basis materials. The material decomposition method was applied to images acquired from a prototype whole-body PCCT scanner. The results showed good agreement between the estimation and known mass concentration values. Factors affecting the performance of material decomposition, such as energy threshold configuration and volume conservation constraint, were also investigated. Changes in accuracy of the mass concentration estimates were demonstrated for four different energy configurations and when volume conservation was assumed.

Entities:  

Keywords:  CT; Energy threshold configuration; Material decomposition; Multi-Energy; Photon counting

Year:  2015        PMID: 26229220      PMCID: PMC4517482          DOI: 10.1117/12.2082069

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  10 in total

1.  Cramér-Rao lower bound of basis image noise in multiple-energy x-ray imaging.

Authors:  E Roessl; C Herrmann
Journal:  Phys Med Biol       Date:  2009-02-03       Impact factor: 3.609

2.  Adaptive nonlocal means filtering based on local noise level for CT denoising.

Authors:  Zhoubo Li; Lifeng Yu; Joshua D Trzasko; David S Lake; Daniel J Blezek; Joel G Fletcher; Cynthia H McCollough; Armando Manduca
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

Review 3.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

4.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

5.  Material separation in x-ray CT with energy resolved photon-counting detectors.

Authors:  Xiaolan Wang; Dirk Meier; Katsuyuki Taguchi; Douglas J Wagenaar; Bradley E Patt; Eric C Frey
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

6.  Estimator for photon counting energy selective x-ray imaging with multibin pulse height analysis.

Authors:  Robert E Alvarez
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

7.  The potential of dual-energy computed tomography for quantitative decomposition of soft tissues to water, protein and lipid in brachytherapy.

Authors:  A Malusek; M Karlsson; M Magnusson; G Alm Carlsson
Journal:  Phys Med Biol       Date:  2013-01-16       Impact factor: 3.609

8.  Quantification of iron in the presence of calcium with dual-energy computed tomography (DECT) in an ex vivo porcine plaque model.

Authors:  Jia Wang; Nitin Garg; Xinhui Duan; Yu Liu; Shuai Leng; Lifeng Yu; Erik L Ritman; Birgit Kantor; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2011-10-28       Impact factor: 3.609

9.  Hepatic iron overload: quantitative MR imaging.

Authors:  J M Gomori; G Horev; H Tamary; J Zandback; L Kornreich; R Zaizov; E Freud; O Krief; J Ben-Meir; H Rotem
Journal:  Radiology       Date:  1991-05       Impact factor: 11.105

10.  Toward quantifying the composition of soft tissues by spectral CT with Medipix3.

Authors:  J Paul Ronaldson; Rafidah Zainon; Nicola Jean Agnes Scott; Steven Paul Gieseg; Anthony P Butler; Philip H Butler; Nigel G Anderson
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

  10 in total
  15 in total

1.  Impact of prior information on material decomposition in dual- and multienergy computed tomography.

Authors:  Liqiang Ren; Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-14

2.  Estimation of signal and noise for a whole-body research photon-counting CT system.

Authors:  Zhoubo Li; Shuai Leng; Zhicong Yu; Steffen Kappler; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-22

3.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system.

Authors:  Shuai Leng; Zhicong Yu; Ahmed Halaweish; Steffen Kappler; Katharina Hahn; Andre Henning; Zhoubo Li; John Lane; David L Levin; Steven Jorgensen; Erik Ritman; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-22

4.  Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study.

Authors:  Liqiang Ren; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2019-12-10       Impact factor: 4.071

5.  150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images.

Authors:  Shuai Leng; Kishore Rajendran; Hao Gong; Wei Zhou; Ahmed F Halaweish; Andre Henning; Steffen Kappler; Matthias Baer; Joel G Fletcher; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2018-11       Impact factor: 6.016

6.  Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study.

Authors:  Rolf Symons; Bernhard Krauss; Pooyan Sahbaee; Tyler E Cork; Manu N Lakshmanan; David A Bluemke; Amir Pourmorteza
Journal:  Med Phys       Date:  2017-08-20       Impact factor: 4.071

7.  Dual Energy CT Kidney Stone Differentiation in Photon Counting Computed Tomography.

Authors:  R Gutjahr; C Polster; A Henning; S Kappler; S Leng; C H McCollough; M U Sedlmair; B Schmidt; B Krauss; T G Flohr
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03

8.  Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.

Authors:  Xu Ji; Ran Zhang; Ke Li; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

9.  Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography.

Authors:  Zhicong Yu; Shuai Leng; Zhoubo Li; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-08-23       Impact factor: 3.609

10.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.