Literature DB >> 28413240

Detection of increased vasa vasorum in artery walls: Improving CT number accuracy using image deconvolution.

Kishore Rajendran1, Shuai Leng1, Steven M Jorgensen2, Dilbar Abdurakhimova1, Erik L Ritman2, Cynthia H McCollough1.   

Abstract

Changes in arterial wall perfusion are an indicator of early atherosclerosis. This is characterized by an increased spatial density of vasa vasorum (VV), the micro-vessels that supply oxygen and nutrients to the arterial wall. Detection of increased VV during contrast-enhanced computed tomography (CT) imaging is limited due to contamination from blooming effect from the contrast-enhanced lumen. We report the application of an image deconvolution technique using a measured system point-spread function, on CT data obtained from a photon-counting CT system to reduce blooming and to improve the CT number accuracy of arterial wall, which enhances detection of increased VV. A phantom study was performed to assess the accuracy of the deconvolution technique. A porcine model was created with enhanced VV in one carotid artery; the other carotid artery served as a control. CT images at an energy range of 25-120 keV were reconstructed. CT numbers were measured for multiple locations in the carotid walls and for multiple time points, pre and post contrast injection. The mean CT number in the carotid wall was compared between the left (increased VV) and right (control) carotid arteries. Prior to deconvolution, results showed similar mean CT numbers in the left and right carotid wall due to the contamination from blooming effect, limiting the detection of increased VV in the left carotid artery. After deconvolution, the mean CT number difference between the left and right carotid arteries was substantially increased at all the time points, enabling detection of the increased VV in the artery wall.

Entities:  

Keywords:  atherosclerosis; contrast media; deconvolution; vasa vasorum; x-ray computed tomography

Year:  2017        PMID: 28413240      PMCID: PMC5391689          DOI: 10.1117/12.2255676

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

Review 1.  The dynamic vasa vasorum.

Authors:  Erik L Ritman; Amir Lerman
Journal:  Cardiovasc Res       Date:  2007-06-29       Impact factor: 10.787

2.  Temporal characterization of the functional density of the vasa vasorum by contrast-enhanced ultrasonography maximum intensity projection imaging.

Authors:  Sang Chol Lee; Chad L Carr; Brian P Davidson; Dilantha Ellegala; Aris Xie; Azzdine Ammi; Todd Belcik; Jonathan R Lindner
Journal:  JACC Cardiovasc Imaging       Date:  2010-12

3.  Initial results from a prototype whole-body photon-counting computed tomography system.

Authors:  Z Yu; S Leng; S M Jorgensen; Z Li; R Gutjahr; B Chen; X Duan; A F Halaweish; L Yu; E L Ritman; C H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015

4.  Arterial Wall Perfusion Measured with Photon Counting Spectral X-ray CT.

Authors:  Steven M Jorgensen; Mark J Korinek; Andrew J Vercnocke; Jill L Anderson; Ahmed Halaweish; Shuai Leng; Cynthia H McCollough; Erik L Ritman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-10-04

5.  How Low Can We Go in Radiation Dose for the Data-Completion Scan on a Research Whole-Body Photon-Counting Computed Tomography System.

Authors:  Zhicong Yu; Shuai Leng; Zhoubo Li; Ahmed F Halaweish; Steffen Kappler; Erik L Ritman; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2016 Jul-Aug       Impact factor: 1.826

6.  Toward quantifying the composition of soft tissues by spectral CT with Medipix3.

Authors:  J Paul Ronaldson; Rafidah Zainon; Nicola Jean Agnes Scott; Steven Paul Gieseg; Anthony P Butler; Philip H Butler; Nigel G Anderson
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

7.  Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies.

Authors:  Ralf Gutjahr; Ahmed F Halaweish; Zhicong Yu; Shuai Leng; Lifeng Yu; Zhoubo Li; Steven M Jorgensen; Erik L Ritman; Steffen Kappler; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2016-07       Impact factor: 6.016

8.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

9.  Compensatory enlargement of human atherosclerotic coronary arteries.

Authors:  S Glagov; E Weisenberg; C K Zarins; R Stankunavicius; G J Kolettis
Journal:  N Engl J Med       Date:  1987-05-28       Impact factor: 91.245

  9 in total
  1 in total

1.  Assessment of candidate elements for development of spectral photon-counting CT specific contrast agents.

Authors:  Johoon Kim; Daniel Bar-Ness; Salim Si-Mohamed; Philippe Coulon; Ira Blevis; Philippe Douek; David P Cormode
Journal:  Sci Rep       Date:  2018-08-14       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.