Spectral discrimination of Cerenkov radiation in scintillating dosimeters.

A M Frelin1, J M Fontbonne, G Ban, J Colin, M Labalme, A Batalla, A Isambert, A Vela, T Leroux.   

Abstract

Radiation therapy accelerators require highly accurate dose deposition and the output must be monitored frequently and regularly. Ionization chambers are the primary tool for this control, but their size, their high voltage needed, and the correction needed for electrons make them unsuitable for use during patient treatment. We have developed a small (1-mm-diam and 1-mm-long active part), flexible, and water-equivalent dosimeter. It is suitable for photon and electron beams without corrections, and performs on line dose measurements. This detector is based on only one scintillating fiber and a CCD camera. A new signal processing is used to remove the effect of Cerenkov radiation background, which only requires a preliminary calibration. Central-axis depth-dose distribution comparisons have been achieved with standard ionization chambers, over a range from 8 to 25 MV photons and from 6 to 21 MeV electrons in order to validate this calibration. Results show a very good agreement, with less than 1% difference between the two detectors.

Entities:  

Mesh:

Year:  2005        PMID: 16266114     DOI: 10.1118/1.2008487

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.

Authors:  Lilie L W Wang; David Klein; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.

Authors:  Frédéric Lacroix; Mathieu Guillot; Malcolm McEwen; Claudiu Cojocaru; Luc Gingras; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Technical note: removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step.

Authors:  Francois Therriault-Proulx; Sam Beddar; Tina M Briere; Louis Archambault; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

5.  Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

Authors:  Mathieu Guillot; Luc Gingras; Louis Archambault; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.

Authors:  Lilie L W Wang; Sam Beddar
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.

Authors:  Francois Lessard; Louis Archambault; Mathieu Plamondon; Philippe Despres; Franccois Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

8.  Projection imaging of photon beams by the Čerenkov effect.

Authors:  Adam K Glaser; Scott C Davis; David M McClatchy; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

9.  Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer.

Authors:  Landon Wootton; Rajat Kudchadker; Andrew Lee; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

10.  Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement.

Authors:  François Therriault-Proulx; Louis Archambault; Luc Beaulieu; Sam Beddar
Journal:  Phys Med Biol       Date:  2012-10-12       Impact factor: 3.609