Literature DB >> 18490811

Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.

J Lambert1, Y Yin, D R McKenzie, S Law, N Suchowerska.   

Abstract

Plastic scintillators have many advantages for dosimetry in external beam radiotherapy. The current method of transmitting the scintillation light to a remote detector is through a solid core optical fibre. When exposed in a high energy therapeutic radiotherapy beam this fibre is subject to an unwanted background signal from Cerenkov light which can exceed the scintillation signal at characteristic angles. We have constructed a plastic scintillation dosimeter that uses an air core light guide to transport the light from the scintillator to the light detector. We show that there is sufficient signal propagation in the air core light guide to allow the scintillator signal to be carried outside the primary beam of a radiotherapy linear accelerator and for a dosimeter to be constructed using a scintillator inserted into the end of the light guide. Studies of the background light generated in the air core light guide, as a function of the angle between the beam and the fibre axis, show that there is no characteristic Cerenkov peak generated in the air core. Depth dose measurements using the air core scintillation dosimeter with no correction for Cerenkov are compared to ionization chamber measurements for a 6 MV photon beam and a 9 MeV electron beam.

Entities:  

Mesh:

Year:  2008        PMID: 18490811     DOI: 10.1088/0031-9155/53/11/021

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.

Authors:  Lilie L W Wang; David Klein; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.

Authors:  Frédéric Lacroix; Mathieu Guillot; Malcolm McEwen; Claudiu Cojocaru; Luc Gingras; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

Authors:  Mathieu Guillot; Luc Gingras; Louis Archambault; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.

Authors:  Lilie L W Wang; Sam Beddar
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Projection imaging of photon beams by the Čerenkov effect.

Authors:  Adam K Glaser; Scott C Davis; David M McClatchy; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Polyethylene Naphthalate Scintillator: A Novel Detector for the Dosimetry of Radioactive Ophthalmic Applicators.

Authors:  Dirk Flühs; Andrea Flühs; Melanie Ebenau; Marion Eichmann
Journal:  Ocul Oncol Pathol       Date:  2015-06-06

7.  Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement.

Authors:  François Therriault-Proulx; Louis Archambault; Luc Beaulieu; Sam Beddar
Journal:  Phys Med Biol       Date:  2012-10-12       Impact factor: 3.609

8.  On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry.

Authors:  François Therriault-Proulx; Luc Beaulieu; Louis Archambault; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

9.  A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.

Authors:  Francois Therriault-Proulx; Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

10.  Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.

Authors:  Masayori Ishikawa; Naomi Nagase; Taeko Matsuura; Junichi Hiratsuka; Ryusuke Suzuki; Naoki Miyamoto; Kenneth Lee Sutherland; Katsuhisa Fujita; Hiroki Shirato
Journal:  J Radiat Res       Date:  2015-01-23       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.