Literature DB >> 23010690

Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

Emilie Roncali1, Jennifer E Phipps, Laura Marcu, Simon R Cherry.   

Abstract

In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration linear regression method (DCI-LR). Phosphor-coated crystals modify the pulse shape to allow continuous DOI information determination, but the relationship between pulse shape and DOI is complex. We are therefore interested in developing a sensitive and robust method to estimate the DOI. Here, linear discriminant analysis (LDA) was implemented to classify the events based on information extracted from the pulse shape. Pulses were acquired with 2×2×20 mm(3) phosphor-coated crystals at five irradiation depths and characterized by their DCI values or Laguerre coefficients. These coefficients were obtained by expanding the pulses on a Laguerre basis set and constituted a unique signature for each pulse. The DOI of individual events was predicted using LDA based on Laguerre coefficients (Laguerre-LDA) or DCI values (DCI-LDA) as discriminant features. Predicted DOIs were compared to true irradiation depths. Laguerre-LDA showed higher sensitivity and accuracy than DCI-LDA and DCI-LR and was also more robust to predict the DOI of pulses with higher statistical noise due to low light levels (interaction depths further from the photodetector face). This indicates that Laguerre-LDA may be more suitable to DOI estimation in smaller crystals where lower collected light levels are expected. This novel approach is promising for calculating DOI using pulse shape discrimination in single-ended readout depth-encoding PET detectors.

Entities:  

Mesh:

Year:  2012        PMID: 23010690      PMCID: PMC3482627          DOI: 10.1088/0031-9155/57/20/6571

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Fluorescence lifetime imaging for the characterization of the biochemical composition of atherosclerotic plaques.

Authors:  Jennifer Phipps; Yinghua Sun; Ramez Saroufeem; Nisa Hatami; Michael C Fishbein; Laura Marcu
Journal:  J Biomed Opt       Date:  2011-09       Impact factor: 3.170

2.  Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes.

Authors:  Yongfeng Yang; Purushottam A Dokhale; Robert W Silverman; Kanai S Shah; Mickel A McClish; Richard Farrell; Gerald Entine; Simon R Cherry
Journal:  Phys Med Biol       Date:  2006-04-10       Impact factor: 3.609

3.  Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.

Authors:  Marnix C Maas; Dennis R Schaart; D J Jan van der Laan; Peter Bruyndonckx; Cedric Lemaître; Freek J Beekman; Carel W E van Eijk
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

4.  Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays.

Authors:  Sara St James; Yongfeng Yang; Yibao Wu; Richard Farrell; Purushottam Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-06-30       Impact factor: 3.609

5.  Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

6.  Time-resolved fluorescence spectra of arterial fluorescent compounds: reconstruction with the Laguerre expansion technique.

Authors:  J M Maarek; L Marcu; W J Snyder; W S Grundfest
Journal:  Photochem Photobiol       Date:  2000-02       Impact factor: 3.421

7.  Identification of nonlinear biological systems using Laguerre expansions of kernels.

Authors:  V Z Marmarelis
Journal:  Ann Biomed Eng       Date:  1993 Nov-Dec       Impact factor: 3.934

8.  Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.

Authors:  Yuchuan Wang; Jurgen Seidel; Benjamin M W Tsui; Juan J Vaquero; Martin G Pomper
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

9.  A prototype PET scanner with DOI-encoding detectors.

Authors:  Yongfeng Yang; Yibao Wu; Jinyi Qi; Sara St James; Huini Du; Purushottam A Dokhale; Kanai S Shah; Richard Farrell; Simon R Cherry
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

10.  Continuous depth-of-interaction encoding using phosphor-coated scintillators.

Authors:  Huini Du; Yongfeng Yang; Jarek Glodo; Yibao Wu; Kanai Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-03-03       Impact factor: 3.609

View more
  8 in total

1.  Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers.

Authors:  Sun Il Kwon; Alessandro Ferri; Alberto Gola; Eric Berg; Claudio Piemonte; Simon R Cherry; Emilie Roncali
Journal:  J Med Imaging (Bellingham)       Date:  2016-11-23

2.  Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI.

Authors:  Jeffrey P Schmall; Suleman Surti; Joel S Karp
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

3.  Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector.

Authors:  Chen-Ming Chang; Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-12-17       Impact factor: 3.609

4.  Investigation of a Model-based Time-over-threshold Technique for Phoswich Crystal Discrimination.

Authors:  Haithem Bouziri; Catherine M Pepin; Konin Koua; Maher Benhouria; Caroline Paulin; Jinsong Ouyang; Marc Normandin; Jean-François Pratte; Georges El Fakhri; Roger Lecomte; Réjean Fontaine
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-05-04

Review 5.  Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

Authors:  Juan José Vaquero; Paul Kinahan
Journal:  Annu Rev Biomed Eng       Date:  2015       Impact factor: 9.590

6.  Improving Depth, Energy and Timing Estimation in PET Detectors with Deconvolution and Maximum Likelihood Pulse Shape Discrimination.

Authors:  Eric Berg; Emilie Roncali; Will Hutchcroft; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Med Imaging       Date:  2016-06-07       Impact factor: 10.048

7.  Predicting the timing properties of phosphor-coated scintillators using Monte Carlo light transport simulation.

Authors:  Emilie Roncali; Jeffrey P Schmall; Varsha Viswanath; Eric Berg; Simon R Cherry
Journal:  Phys Med Biol       Date:  2014-04-02       Impact factor: 3.609

8.  A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography.

Authors:  Eric Berg; Emilie Roncali; Maciej Kapusta; Junwei Du; Simon R Cherry
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

  8 in total