Literature DB >> 22986413

Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses.

C Güldner1, A Ningo, J Voigt, I Diogo, J Heinrichs, R Weber, T Wilhelm, M Fiebich.   

Abstract

More than 10 years ago, cone-beam-computed tomography (CBCT) was introduced in ENT radiology. Until now, the focus of research was to evaluate clinical limits of this technique. The aim of this work is the evaluation of specific dosages and the identification of potential optimization in the performance of CBCT of the paranasal sinuses. Based on different tube parameters (tube current, tube voltage, and rotation angles), images of the nose and the paranasal sinuses were taken on a phantom head with the Accu-I-tomo F17 (Morita, Kyoto, Japan). The dosages applied to the lens and parotid gland were measured with OSL dosimetry. The imaging quality was evaluated by independent observers. All datasets were reviewed according to a checklist of surgically important anatomic structures. Even for lowest radiation exposure (4 mA, 76 kV, 180°, computed tomography dosage index (CTDI) = 1.8 mGy), the imaging quality was sufficient. Of course a significant reduction of the imaging quality could be seen, so a reliable mean was set for 4 mA, 84 kV, and 180° rotation angle (CTDI = 2.4 mGy). In this combination, a reduction of 92 % in lens-dose and of 77 % of dosage at the parotid gland was observed in comparison to the maximal possible adjustments (8 mA, 90 kV, 360°, CTDI = 10.9 mGy). There is potential for optimization in CBCT. Changing the rotation angle (180° instead of 360°) leads to a dose reduction of 50 %. Furthermore from clinical point of view in case of chronic rhinosinusitis a relevant reduction of dosage is possible. Therefore, it is necessary to intensify the interdisciplinary discussion about the disease specifics required quality of imaging.

Entities:  

Mesh:

Year:  2012        PMID: 22986413     DOI: 10.1007/s00405-012-2177-2

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  18 in total

1.  [On the practical value of differences in the level of the lamina cribrosa of the ethmoid].

Authors:  P KEROS
Journal:  Z Laryngol Rhinol Otol       Date:  1962-11

2.  The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens.

Authors:  Thiemo Kurzweg; Carsten V Dalchow; Martin Bremke; Omid Majdani; Ingo Kureck; Reinald Knecht; Jochen A Werner; Afshin Teymoortash
Journal:  Ear Hear       Date:  2010-06       Impact factor: 3.570

3.  [Digital volume tomography (DVT) and multislice spiral CT (MSCT): an objective examination of dose and image quality].

Authors:  Y Kyriakou; D Kolditz; O Langner; J Krause; W Kalender
Journal:  Rofo       Date:  2010-10-04

4.  The surgeon's view of the anterior ethmoid artery.

Authors:  D Simmen; U Raghavan; H R Briner; M Manestar; B Schuknecht; P Groscurth; N S Jones
Journal:  Clin Otolaryngol       Date:  2006-06       Impact factor: 2.597

5.  Rotational tomography of the normal and reconstructed middle ear in temporal bones: an experimental study.

Authors:  Ch Offergeld; J Kromeier; A Aschendorff; W Maier; Th Klenzner; Th Beleites; Th Zahnert; J Schipper; R Laszig
Journal:  Eur Arch Otorhinolaryngol       Date:  2006-10-18       Impact factor: 2.503

6.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

7.  Characteristics of an OSLD in the diagnostic energy range.

Authors:  Rani M Al-Senan; Mustapha R Hatab
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

8.  Radiological examinations of the anatomy of the inferior turbinate using digital volume tomography (DVT).

Authors:  L Balbach; V Trinkel; C Guldner; S Bien; A Teymoortash; J A Werner; M Bremke
Journal:  Rhinology       Date:  2011-06       Impact factor: 3.681

9.  Significant reduction in dental cone beam computed tomography (CBCT) eye dose through the use of leaded glasses.

Authors:  R Prins; L T Dauer; D C Colosi; B Quinn; N J Kleiman; G C Bohle; B Holohan; A Al-Najjar; T Fernandez; M Bonvento; R D Faber; H Ching; A D Goren
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2011-07-28

10.  [The roof of the anterior ethmoid: a locus minoris resistentiae in the skull base].

Authors:  J Kainz; H Stammberger
Journal:  Laryngol Rhinol Otol (Stuttg)       Date:  1988-04
View more
  16 in total

Review 1.  Comprehensive review on endonasal endoscopic sinus surgery.

Authors:  Rainer K Weber; Werner Hosemann
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2015-12-22

2.  Visualization of anatomy in normal and pathologic middle ears by cone beam CT.

Authors:  Christian Güldner; Isabell Diogo; Eva Bernd; Stephanie Dräger; Magis Mandapathil; Afshin Teymoortash; Hesham Negm; Thomas Wilhelm
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-10-17       Impact factor: 2.503

3.  Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

Authors:  C Leiva-Salinas; L Flors; P Gras; F Más-Estellés; P Lemercier; J T Patrie; M Wintermark; L Martí-Bonmatí
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-26       Impact factor: 3.825

4.  A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose.

Authors:  R Pauwels; O Silkosessak; R Jacobs; R Bogaerts; H Bosmans; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2014-04-08       Impact factor: 2.419

5.  Evaluation of variations in sinonasal region with computed tomography.

Authors:  Ufuk Dasar; Erkan Gokce
Journal:  World J Radiol       Date:  2016-01-28

Review 6.  [Digital volume tomography : Dedicated scanner and cone beam CT with C‑arm systems].

Authors:  M Fiebich; D Weber
Journal:  Radiologe       Date:  2018-03       Impact factor: 0.635

7.  Transcanal Computed Tomography Views for Transcanal Endoscopic Lateral Skull Base Surgery: Pilot Cadaveric Study.

Authors:  Rory J Lubner; Samuel R Barber; Renata M Knoll; Judith Kempfle; Daniel J Lee; Katherine L Reinshagen; Aaron K Remenschneider; Elliott D Kozin
Journal:  J Neurol Surg B Skull Base       Date:  2019-11-07

8.  Visualisation of the Bonebridge by means of CT and CBCT.

Authors:  Christian Güldner; Julia Heinrichs; Rainer Weiß; Annette Paula Zimmermann; Benjamin Dassinger; Siegfried Bien; Jochen Alfred Werner; Isabell Diogo
Journal:  Eur J Med Res       Date:  2013-09-03       Impact factor: 2.175

9.  Anatomical Variations of Ostiomeatal Complex in CBCT of Patients Seeking Rhinoplasty.

Authors:  Leila Khojastepour; Sabah Mirhadi; Seyed Alireza Mesbahi
Journal:  J Dent (Shiraz)       Date:  2015-03

10.  Application of a newly developed software program for image quality assessment in cone-beam computed tomography.

Authors:  Marcus Vinicius Linhares de Oliveira; António Carvalho Santos; Graciano Paulo; Paulo Sergio Flores Campos; Joana Santos
Journal:  Imaging Sci Dent       Date:  2017-06-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.