[Digital volume tomography : Dedicated scanner and cone beam CT with C‑arm systems].

M Fiebich1, D Weber2.   

Abstract

CLINICAL/METHODICAL ISSUE: Digital volume tomography (DVT) and cone-beam computed tomography (CT) with C‑arm systems have become established three-dimensional imaging systems as an alternative to CT in some application areas. STANDARD RADIOLOGICAL
METHODS: The technology of the systems is well developed so that they have become a competing method to CT imaging in terms of image quality and radiation exposure. PERFORMANCE: An advantage is the better spatial resolution, preferably with dedicated scanner systems, especially in the z direction. The radiation exposure of CT, cone beam CT and DVT are comparable, if the exposure parameter in CT imaging can be adjusted to the lower exposure levels. ACHIEVEMENTS: Advantages of these systems are that they can be used for imaging in a better workflow or to acquire images under conditions not possible in CT, e. g. imaging under stress in orthopedics or to take images in the corona technique with a horizontal gantry in cone-beam CT mammography PRACTICAL RECOMMENDATIONS: The use of three-dimensional imaging is becoming more frequent and will replace planar radiography in additional clinical situations. The three-dimensional imaging without superpositioning of structures has advantages in the visibility of structures and the spatial relation to other organs and structures. In guidelines and recommendations, the number of recommendations given for the use of three-dimensional imaging is increasing. This leads to a small increase in the radiation exposure of patients, a trend which is reflected in the annual reports of the Federal Office for Radiation Protection.

Entities:  

Keywords:  Cone beam CT; Image quality; Quality assurance; Radiation exposure; Three-dimensional imaging

Mesh:

Year:  2018        PMID: 29417159     DOI: 10.1007/s00117-018-0360-1

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  21 in total

1.  The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens.

Authors:  Thiemo Kurzweg; Carsten V Dalchow; Martin Bremke; Omid Majdani; Ingo Kureck; Reinald Knecht; Jochen A Werner; Afshin Teymoortash
Journal:  Ear Hear       Date:  2010-06       Impact factor: 3.570

Review 2.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

3.  The Dynamic Spatial Reconstructor: An X-Ray Video-Fluoroscopic CT Scanner for Dynamic Volume Imaging of Moving Organs.

Authors:  R A Robb
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

4.  Assessment of effective radiation dose of an extremity CBCT, MSCT and conventional X ray for knee area using MOSFET dosemeters.

Authors:  Juha Koivisto; Timo Kiljunen; Jan Wolff; Mika Kortesniemi
Journal:  Radiat Prot Dosimetry       Date:  2013-07-03       Impact factor: 0.972

Review 5.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

Review 6.  Review of clinical studies and first clinical experiences with a commercially available cone-beam breast CT in Europe.

Authors:  Susanne Wienbeck; Joachim Lotz; Uwe Fischer
Journal:  Clin Imaging       Date:  2016-11-17       Impact factor: 1.605

7.  Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses.

Authors:  C Güldner; A Ningo; J Voigt; I Diogo; J Heinrichs; R Weber; T Wilhelm; M Fiebich
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-09-18       Impact factor: 2.503

8.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.

Authors:  W A Kalender; W Seissler; E Klotz; P Vock
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

9.  Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast.

Authors:  Willi A Kalender; Daniel Kolditz; Christian Steiding; Veikko Ruth; Ferdinand Lück; Ann-Christin Rößler; Evelyn Wenkel
Journal:  Eur Radiol       Date:  2016-06-15       Impact factor: 5.315

10.  Target volume coverage and dose to organs at risk in prostate cancer patients. Dose calculation on daily cone-beam CT data sets.

Authors:  P Hüttenrauch; M Witt; D Wolff; S Bosold; R Engenhart-Cabillic; J Sparenberg; H Vorwerk; K Zink
Journal:  Strahlenther Onkol       Date:  2014-01-16       Impact factor: 3.621

View more
  1 in total

1.  [The quiet evolution].

Authors:  S Delorme; R Loose
Journal:  Radiologe       Date:  2018-03       Impact factor: 0.635

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.