Literature DB >> 22956562

French diagnostic reference levels in diagnostic radiology, computed tomography and nuclear medicine: 2004-2008 review.

P Roch1, B Aubert.   

Abstract

After 5 y of collecting data on diagnostic reference levels (DRLs), the Nuclear Safety and Radiation Protection French Institute (IRSN) presents the analyses of this data. The analyses of the collected data for radiology, computed tomography (CT) and nuclear medicine allow IRSN to estimate the level of regulatory application by health professionals and the representativeness of current DRL in terms of relevant examinations, dosimetric quantities, numerical values and patient morphologies. Since 2004, the involvement of professionals has highly increased, especially in nuclear medicine, followed by CT and then by radiology. Analyses show some discordance between regulatory examinations and clinical practice. Some of the dosimetric quantities used for the DRL setting are insufficient or not relevant enough, and some numerical values should also be reviewed. On the basis of these findings, IRSN formulates recommendations to update regulatory DRL with current and relevant examination lists, dosimetric quantities and numerical values.

Entities:  

Mesh:

Year:  2012        PMID: 22956562     DOI: 10.1093/rpd/ncs152

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  19 in total

1.  The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography.

Authors:  Joana Santos; Shane Foley; Graciano Paulo; Mark F McEntee; Louise Rainford
Journal:  Pediatr Radiol       Date:  2015-08-05

2.  Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.

Authors:  Federica Palorini; Daniela Origgi; Claudio Granata; Domenica Matranga; Sergio Salerno
Journal:  Eur Radiol       Date:  2014-02       Impact factor: 5.315

3.  Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Authors:  Peijie Lv; Zhigang Zhou; Jie Liu; Yaru Chai; Huiping Zhao; Hua Guo; Daniele Marin; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

Review 4.  Radiation Safety in Nuclear Medicine Procedures.

Authors:  Sang-Geon Cho; Jahae Kim; Ho-Chun Song
Journal:  Nucl Med Mol Imaging       Date:  2016-02-19

5.  Emergency assessment of patients with acute abdominal pain using low-dose CT with iterative reconstruction: a comparative study.

Authors:  Pierre-Alexandre Poletti; Minerva Becker; Christoph D Becker; Alice Halfon Poletti; Olivier T Rutschmann; Habib Zaidi; Thomas Perneger; Alexandra Platon
Journal:  Eur Radiol       Date:  2017-01-12       Impact factor: 5.315

6.  An Australian local diagnostic reference level for paediatric whole-body 18F-FDG PET/CT.

Authors:  Essam Mohammed Alkhybari; Mark F McEntee; Kathy P Willowson; Patrick C Brennan; Theo Kitsos; Peter L Kench
Journal:  Br J Radiol       Date:  2019-03-05       Impact factor: 3.039

7.  Local reference levels and organ doses from pediatric cardiac interventional procedures.

Authors:  S Barnaoui; J L Rehel; H Baysson; Y Boudjemline; B Girodon; M O Bernier; D Bonnet; B Aubert
Journal:  Pediatr Cardiol       Date:  2014-03-21       Impact factor: 1.655

8.  Consideration of diagnostic reference levels for pediatric chest X-ray examinations.

Authors:  Yasuki Asada; Takuma Ichikawa
Journal:  Radiol Phys Technol       Date:  2019-08-31

9.  Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010.

Authors:  Cécile Etard; Bernard Aubert; Myriam Mezzarobba; Marie-Odile Bernier
Journal:  Pediatr Radiol       Date:  2014-07-17

10.  Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

Authors:  Timo De Bondt; Tom Mulkens; Federica Zanca; Lotte Pyfferoen; Jan W Casselman; Paul M Parizel
Journal:  Eur Radiol       Date:  2016-06-03       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.