Literature DB >> 15906282

Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE: application to high-resolution real-time cardiac steady-state free precession.

Jeffrey Tsao1, Sebastian Kozerke, Peter Boesiger, Klaas P Pruessmann.   

Abstract

In k-t BLAST and k-t SENSE, data acquisition is accelerated by sparsely sampling k-space over time. This undersampling in k-t space causes the object signals to be convolved with a point spread function in x-f space (x = spatial position, f = temporal frequency). The resulting aliasing is resolved by exploiting spatiotemporal correlations within the data. In general, reconstruction accuracy can be improved by controlling the k-t sampling pattern to minimize signal overlap in x-f space. In this work, we describe an approach to obtain generally favorable patterns for typical image series without specific knowledge of the image series itself. These optimized sampling patterns were applied to free-breathing, untriggered (i.e., real-time) cardiac imaging with steady-state free precession (SSFP). Eddy-current artifacts, which are otherwise increased drastically in SSFP by the undersampling, were minimized using alternating k-space sweeps. With the synergistic combination of the k-t approach with optimized sampling and SSFP with alternating k-space sweeps, it was possible to achieve a high signal-to-noise ratio, high contrast, and high spatiotemporal resolutions, while achieving substantial immunity against eddy currents. Cardiac images are shown, demonstrating excellent image quality and an in-plane resolution of approximately 2.0 mm at >25 frames/s, using one or more receiver coils.

Mesh:

Year:  2005        PMID: 15906282     DOI: 10.1002/mrm.20483

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

Review 1.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Bayesian parallel imaging with edge-preserving priors.

Authors:  Ashish Raj; Gurmeet Singh; Ramin Zabih; Bryan Kressler; Yi Wang; Norbert Schuff; Michael Weiner
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

3.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

Review 4.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

5.  Event-related single-shot volumetric functional magnetic resonance inverse imaging of visual processing.

Authors:  Fa-Hsuan Lin; Thomas Witzel; Joseph B Mandeville; Jonathan R Polimeni; Thomas A Zeffiro; Douglas N Greve; Graham Wiggins; Lawrence L Wald; John W Belliveau
Journal:  Neuroimage       Date:  2008-04-23       Impact factor: 6.556

6.  Improved time series reconstruction for dynamic magnetic resonance imaging.

Authors:  Uygar Sümbül; Juan M Santos; John M Pauly
Journal:  IEEE Trans Med Imaging       Date:  2009-01-13       Impact factor: 10.048

Review 7.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

8.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

9.  Denoising MRI using spectral subtraction.

Authors:  M Arcan Erturk; Paul A Bottomley; Abdel-Monem M El-Sharkawy
Journal:  IEEE Trans Biomed Eng       Date:  2013-01-10       Impact factor: 4.538

10.  Autocalibrating motion-corrected wave-encoding for highly accelerated free-breathing abdominal MRI.

Authors:  Feiyu Chen; Tao Zhang; Joseph Y Cheng; Xinwei Shi; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2016-12-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.