Literature DB >> 29357015

Influence of principal component analysis acceleration factor on velocity measurement in 2D and 4D PC-MRI.

Gwenaël Pagé1, Jérémie Bettoni2, Anne-Virginie Salsac3, Olivier Balédent4,5.   

Abstract

OBJECTIVE: The objective of the study was to determine how to optimize 2D and 4D phase-contrast magnetic resonance imaging (PC-MRI) acquisitions to acquire flow velocities in millimetric vessels. In particular, we search for the best compromise between acquisition time and accuracy and assess the influence of the principal component analysis (PCA).
MATERIALS AND METHODS: 2D and 4D PC-MRI measurements are conducted within two in vitro vessel phantoms: a Y-bifurcation phantom, the branches of which range from 2 to 5 mm in diameter, and a physiological subject-specific phantom of the carotid bifurcation. The same sequences are applied in vivo in carotid vasculature.
RESULTS: For a vessel oriented in the axial direction, both 2D and axial 4D PC-MRI provided accuracy measurements regardless of the k-t PCA factor, while the acquisition time is reduced by a factor 6 for k-t PCA maximum value. The in vivo measurements show that the proposed sequences are adequate to acquire 2D and 4D velocity fields in millimetric vessels and with clinically realistic time durations.
CONCLUSION: The study shows the feasibility of conducting fast, high-resolution PC-MRI flow measurements in millimetric vessels and that it is worth maximizing the k-t PCA factor to reduce the acquisition time in the case of 2D and 4D axial acquisitions.

Keywords:  Cine MRI; Feasibility studies; Imaging phantoms; Principal component analysis

Mesh:

Year:  2018        PMID: 29357015     DOI: 10.1007/s10334-018-0673-0

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  38 in total

1.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

2.  Highly undersampled phase-contrast flow measurements using compartment-based k-t principal component analysis.

Authors:  Daniel Giese; Tobias Schaeffter; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2012-04-23       Impact factor: 4.668

3.  High resolution three-dimensional cardiac perfusion imaging using compartment-based k-t principal component analysis.

Authors:  Viton Vitanis; Robert Manka; Daniel Giese; Henrik Pedersen; Sven Plein; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2010-10-06       Impact factor: 4.668

4.  Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI.

Authors:  Shuhei Yamashita; Haruo Isoda; Masaya Hirano; Hiroyasu Takeda; Shoichi Inagawa; Yasuo Takehara; Marcus T Alley; Michael Markl; Norbert J Pelc; Harumi Sakahara
Journal:  J Magn Reson Imaging       Date:  2007-03       Impact factor: 4.813

5.  In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

Authors:  S Wetzel; S Meckel; A Frydrychowicz; L Bonati; E-W Radue; K Scheffler; J Hennig; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

6.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

7.  Comparison of blood flow velocity quantification by 4D flow MR imaging with ultrasound at the carotid bifurcation.

Authors:  A Harloff; T Zech; F Wegent; C Strecker; C Weiller; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2013-02-14       Impact factor: 3.825

8.  Wall shear stress calculations based on 3D cine phase contrast MRI and computational fluid dynamics: a comparison study in healthy carotid arteries.

Authors:  Merih Cibis; Wouter V Potters; Frank J H Gijsen; Henk Marquering; Ed vanBavel; Antonius F W van der Steen; Aart J Nederveen; Jolanda J Wentzel
Journal:  NMR Biomed       Date:  2014-05-12       Impact factor: 4.044

9.  Quantitative magnetic resonance flow imaging.

Authors:  N J Pelc; F G Sommer; K C Li; T J Brosnan; R J Herfkens; D R Enzmann
Journal:  Magn Reson Q       Date:  1994-09

10.  Cerebrospinal fluid dynamics and relation with blood flow: a magnetic resonance study with semiautomated cerebrospinal fluid segmentation.

Authors:  O Balédent; M C Henry-Feugeas; I Idy-Peretti
Journal:  Invest Radiol       Date:  2001-07       Impact factor: 6.016

View more
  2 in total

1.  Quantitative assessment of the flow distribution in the branches of the external carotid by non-injected flow MRI.

Authors:  Jérémie Bettoni; Gwénaël Pagé; Anne-Virginie Salsac; Jean-Marc Constans; Sylvie Testelin; Bernard Devauchelle; Olivier Balédent; Stéphanie Dakpé
Journal:  Dentomaxillofac Radiol       Date:  2018-07-13       Impact factor: 2.419

2.  Highly accelerated 4D flow cardiovascular magnetic resonance using a pseudo-spiral Cartesian acquisition and compressed sensing reconstruction for carotid flow and wall shear stress.

Authors:  Eva S Peper; Lukas M Gottwald; Qinwei Zhang; Bram F Coolen; Pim van Ooij; Aart J Nederveen; Gustav J Strijkers
Journal:  J Cardiovasc Magn Reson       Date:  2020-01-20       Impact factor: 5.364

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.