| Literature DB >> 22927949 |
Guo Yin1, Ya Xing Wang, Zhi Yun Zheng, Hua Yang, Liang Xu, Jost B Jonas.
Abstract
PURPOSE: To investigate the normative data of ocular axial length and its associations in Chinese.Entities:
Mesh:
Year: 2012 PMID: 22927949 PMCID: PMC3424225 DOI: 10.1371/journal.pone.0043172
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Histogram showing distribution of the ocular axial length in the Beijing Eye Study 2011.
Univariate Analysis of Associations between Axial Length and Systemic and Ocular Parameters in the Beijing Eye Study 2011.
|
| Correlation Coefficient | Steepness of the Regression Line | 95% CI of Steepness of Regression Line | |
| Systemic Parameters | ||||
| Age (Years) | <0.001 | 0.09 | 0.01 | 0.006, 0.014 |
| Gender | <0.001 | −0.23 | −0.52 | −0.61, −0.45 |
| Body height (cm) | <0.001 | 0.29 | 0.04 | 0.04, 0.05 |
| Body weight (kg) | <0.001 | 0.09 | 0.01 | 0.005, 0.012 |
| Body mass index | <0.001 | −0.10 | −0.03 | −0.04,−0.02 |
| Level of education | <0.001 | 0.26 | 0.28 | 0.24, 0.32 |
| Rural/Urban Region | <0.001 | 0.24 | 0.54 | 0.46, 0.62 |
| Ocular Parameters | ||||
| Central Corneal Thickness ( µm) | <0.001 | 0.11 | 0.004 | 0.003, 0.005 |
| Anterior Corneal Curvature (mm) | ||||
| Flattest Meridian | <0.001 | 0.52 | 2.27 | 2.14, 2.40 |
| Steepest Meridian | <0.001 | 0.49 | 2.12 | 1.99, 2.26 |
| Corneal diameter (mm) | 0.001 | 0.06 | 0.07 | 0.03, 0.11 |
| Anterior Chamber depth (mm) | <0.001 | 0.34 | 0.77 | 0.69, 0.84 |
| Lens thickness (mm) | <0.001 | −0.11 | −0.37 | −0.49, −0.25 |
| Refractive error (Diopters): Spherical error | <0.001 | −0.60 | −0.35 | −0.36, −0.33 |
| Cylindrical error (absolute) | 0.046 | 0.04 | 0.06 | 0.001, 0.11 |
| Spherical equivalent | <0.001 | −0.62 | −0.34 | −0.35, −0.32 |
| Intraocular pressure (mmHg) | 0.396 | 0.02 | 0.006 | −0.01, 0.02 |
| Pupil diameter (mm) | <0.001 | 0.21 | 0.30 | 0.25, 0.35 |
| Pupil distance | <0.001 | 0.18 | 0.05 | 0.04, 0.05 |
| BCVA (logMAR) | <0.001 | 0.08 | 0.41 | 0.18, 0.63 |
P-Value = statistical significance of the association
CI: = confidence interval
BCVA: = best corrected visual acuity
logMAR: = logarithmic value of the minimal angle of resolution
Multivariate Analysis of Associations between Axial Length and Systemic and Ocular Parameters in the Beijing Eye Study 2011.
|
| Regression Coefficient (non-standard Beta) | 95% CI of Un-Standardized Regression Coefficient | Standardized Regression Coefficient | |
| Systemic Parameters | ||||
| Age (Years) | <0.001 | 0.02 | 0.02, 0.03 | 0.20 |
| Gender | 0.32 | −0.02 | −0.07, 0.02 | −0.01 |
| Body height (cm) | 0.01 | 0.004 | 0.001, 0.007 | 0.03 |
| Body weight (kg) | 0.86 | 0.000 | −0.002, 0.002 | 0.002 |
| Level of education | <0.001 | 0.04 | 0.02, 0.03 | 0.04 |
| Rural/Urban Region | <0.001 | 0.12 | 0.07, 0.16 | 0.05 |
| Ocular Parameters | ||||
| Central corneal thickness ( µm) | <0.001 | 0.001 | 0.001, 0.002 | 0.03 |
| Anterior corneal curvature, flat meridian (mm) | <0.001 | 1.04 | 0.84, 1.24 | 0.24 |
| Anterior corneal curvature, steep meridian (mm) | <0.001 | 1.06 | 0.86, 1.26 | 0.25 |
| Corneal Diameter (mm) | 0.25 | −0.01 | −0.028, 0.007 | −0.01 |
| Pupil Diameter (mm) | 0.02 | 0.03 | 0.005, 0.048 | 0.02 |
| Pupil distance (mm) | 0.040 | −0.004 | −0.008, 0.000 | −0.02 |
| Anterior chamber depth (mm) | <0.001 | 1.20 | 1.14, 1.27 | 0.37 |
| Lens thickness (mm) | <0.001 | 0.20 | 0.14, 0.26 | 0.06 |
| Refractive error (Diopters):Spherical Equivalent | <0.001 | −0.29 | −0.33, −0.24 | −0.51 |
| Spherical error | 0.08 | −0.04 | −0.09, 0.004 | −0.07 |
| Cylindrical error | 0.59 | −0.01 | −0.04, 0.02 | −0.006 |
| BCVA (logMAR) | <0.001 | −0.76 | −0.94, −0.59 | −0.08 |
P-value = statistical significance of the association
CI = confidence interval
BCVA = best corrected visual acuity
logMAR = logarithmic value of the minimal angle of resolution
Multivariate Analysis of Associations between Ocular Length and Systemic and Ocular Parameters as Independent Parameters that Remained Significantly Associated with Axial Length after Stepwise Exclusion of Parameters.
|
| Regression Coefficient (un-standardized Beta) | 95% CI of Un-Standardized Regression Coefficient | Standardized Regression Coefficient | Variance Inflation Factor | |
| Systemic Parameters | |||||
| Age (Years) | <0.001 | 0.02 | 0.02, 0.04 | 0.20 | 1.84 |
| Body height (cm) | <0.001 | 0.006 | 0.004, 0.009 | 0.05 | 1.38 |
| Level of education | <0.001 | 0.05 | 0.03, 0.07 | 0.04 | 1.64 |
| Rural/Urban Region | <0.001 | 0.11 | 0.07, 0.15 | 0.05 | 1.67 |
| Ocular Parameters | |||||
| Central corneal thickness ( µm) | <0.001 | 0.001 | 0.001, 0.002 | 0.03 | 1.05 |
| Anterior Corneal Curvature (mm), flat meridian | <0.001 | 1.05 | 0.88, 1.22 | 0.24 | 7.23 |
| Anterior Corneal Curvature (mm), steep meridian | <0.001 | 1.06 | 0.90, 1.23 | 0.25 | 7.26 |
| Pupil diameter (mm) | 0.01 | 0.03 | 0.01, 0.05 | 0.02 | 1.14 |
| Pupil distance (mm) | 0.052 | −0.004 | −0.01, 0.000 | −0.02 | 1.16 |
| Anterior chamber depth (mm) | <0.001 | 1.13 | 1.07, 1.19 | 0.35 | 1.67 |
| Lens thickness (mm) | <0.001 | 0.14 | 0.08, 0.20 | 0.04 | 1.56 |
| Refractive error (Diopters) | <0.001 | −0.32 | −0.33, −0.32 | −0.58 | 1.36 |
| BCVA (logMAR) | <0.001 | −0.79 | −0.96, −0.61 | −0.08 | 1.72 |
P value = statistical significance of the association
CI = confidence interval
BCVA = best corrected visual acuity
logMAR = logarithmic value of the minimal angle of resolution
Multivariate Analysis of Associations between Ocular Axial Length and Systemic and Ocular Parameters in the Beijing Eye Study 2011. Highly Myopic Eyes with a refractive error of more than −8 diopters were excluded.
|
| Regression Coefficient (un-standardized Beta) | 95% CI of Un-Standardized Regression Coefficient | Standardized Regression Coefficient | Variance Inflation Factor | |
| Systemic Parameters | |||||
| Age (Years) | <0.001 | 0.02 | 0.02, 0.03 | 0.23 | 1.89 |
| Body height (cm) | <0.001 | 0.006 | 0.004, 0.008 | 0.05 | 1.38 |
| Level of education | <0.001 | 0.06 | 0.04, 0.07 | 0.06 | 1.64 |
| Rural/Urban Region | <0.001 | 0.11 | 0.07, 0.14 | 0.05 | 1.67 |
| Ocular Parameters | |||||
| Central corneal thickness ( µm) | <0.001 | 0.001 | 0.001, 0.002 | 0.04 | 1.05 |
| Anterior Corneal Curvature (mm) flat | <0.001 | 0.96 | 0.81, 1.12 | 0.25 | 7.26 |
| Anterior Corneal Curvature (mm) steep | <0.001 | 1.12 | 0.96, 1.27 | 0.29 | 7.29 |
| Pupil diameter (mm) | 0.002 | 0.03 | 0.01, 0.05 | 0.03 | 1.15 |
| Pupil distance (mm) | 0.069 | −0.003 | −0.007, 0 | −0.02 | 1.16 |
| Anterior chamber depth (mm) | <0.001 | 1.13 | 1.08, 1.19 | 0.39 | 1.65 |
| Lens thickness (mm) | <0.001 | 0.12 | 0.06, 0.18 | 0.04 | 1.55 |
| Refractive error (Diopters) | <0.001 | −0.30 | −0.31, −0.29 | −0.48 | 1.26 |
| BCVA (logMAR) | <0.001 | −0.81 | −0.98, −0.63 | −0.09 | 1.65 |
P value = statistical significance of the association
CI = confidence interval
BCVA = best corrected visual acuity
logMAR = logarithmic value of the minimal angle of resolution