Literature DB >> 22920820

Importance of blood glucose meter and carbohydrate estimation accuracy.

Naunihal S Virdi1, John J Mahoney.   

Abstract

BACKGROUND: The clinical significance of blood glucose meter (BGM) error in the presence of increasing carbohydrate errors in diabetes patients who use both the BGM result and the carbohydrate estimation to dose insulin is unknown.
METHODS: This Monte Carlo simulation modeled diabetes patients who calculate insulin dosages based on BGM results and carbohydrate estimations. It evaluated the likelihood of on-target insulin dosing and clinically significant insulin dose errors based on data from five BGMs with different levels of performance (expressed as bias and imprecision [coefficient of variation (%CV)]) and increasing levels of carbohydrate estimation errors. The study was performed across three separate preprandial glucose (PPG) ranges (90-150, 150-270, and 270-450 mg/dl).
RESULTS: When carbohydrate estimation is accurate (%CV = 0%), the likelihood for on-target insulin doses ranged 50.1-98.5%. The likelihood depended on BGM performance and PPG range. In the presence of carbohydrate estimation errors (%CV = 5-20%), the likelihood of on-target insulin dosages markedly decreased (range, 27.2-80.1%) for all BGMs, the likelihood of insulin underdosing (range, 0-12.8%) and overdosing (range, 0-32.3%) increased, and the influence of BGM error on insulin dosing accuracy was blunted. Even in the presence of carbohydrate error, the BGM with the best performance (bias 1.35% and %CV = 4.84) had the highest probability for on-target insulin dosages.
CONCLUSIONS: Both BGM and carbohydrate estimation error contribute to insulin dosing inaccuracies. The BGM with the best performance was associated with the most on-target insulin dosages.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22920820      PMCID: PMC3440165          DOI: 10.1177/193229681200600425

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  11 in total

1.  Regulatory controversies surround blood glucose monitoring devices.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

2.  Impact of blood glucose self-monitoring errors on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: an in silico study.

Authors:  Marc D Breton; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

3.  Standards of medical care in diabetes--2011.

Authors: 
Journal:  Diabetes Care       Date:  2011-01       Impact factor: 19.112

4.  Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose.

Authors:  J C Boyd; D E Bruns
Journal:  Clin Chem       Date:  2001-02       Impact factor: 8.327

5.  Patient understanding of food labels: the role of literacy and numeracy.

Authors:  Russell L Rothman; Ryan Housam; Hilary Weiss; Dianne Davis; Rebecca Gregory; Tebeb Gebretsadik; Ayumi Shintani; Tom A Elasy
Journal:  Am J Prev Med       Date:  2006-11       Impact factor: 5.043

6.  System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197.

Authors:  Guido Freckmann; Annette Baumstark; Nina Jendrike; Eva Zschornack; Serge Kocher; Jacques Tshiananga; Frank Heister; Cornelia Haug
Journal:  Diabetes Technol Ther       Date:  2010-03       Impact factor: 6.118

Review 7.  Narrative review: a rational approach to starting insulin therapy.

Authors:  Arshag D Mooradian; Marla Bernbaum; Stewart G Albert
Journal:  Ann Intern Med       Date:  2006-07-18       Impact factor: 25.391

Review 8.  Outpatient insulin therapy in type 1 and type 2 diabetes mellitus: scientific review.

Authors:  Dawn E DeWitt; Irl B Hirsch
Journal:  JAMA       Date:  2003-05-07       Impact factor: 56.272

9.  The impact of non-model-related variability on blood glucose prediction.

Authors:  Jonas Kildegaard; Jette Randløv; Jens Ulrik Poulsen; Ole K Hejlesen
Journal:  Diabetes Technol Ther       Date:  2007-08       Impact factor: 6.118

10.  Improving the estimation of mealtime insulin dose in adults with type 1 diabetes: the Normal Insulin Demand for Dose Adjustment (NIDDA) study.

Authors:  Jiansong Bao; Heather R Gilbertson; Robyn Gray; Diane Munns; Gabrielle Howard; Peter Petocz; Stephen Colagiuri; Jennie C Brand-Miller
Journal:  Diabetes Care       Date:  2011-10       Impact factor: 19.112

View more
  10 in total

1.  Analysis: New point-of-care blood glucose monitoring system for the hospital demonstrates satisfactory analytical accuracy using blood from critically ill patients--an important step toward improved blood glucose control in the hospital.

Authors:  Jeffrey I Joseph
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

Review 2.  Performance of Cleared Blood Glucose Monitors.

Authors:  David C Klonoff; Priya Prahalad
Journal:  J Diabetes Sci Technol       Date:  2015-06-08

3.  A Model of Self-Monitoring Blood Glucose Measurement Error.

Authors:  Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2017-03-16

4.  Bolus Insulin Dose Error Distributions Based on Results From Two Clinical Trials Comparing Blood Glucose Monitoring Systems.

Authors:  Scott Pardo; Nancy Dunne; David A Simmons
Journal:  J Diabetes Sci Technol       Date:  2017-06-12

5.  How Should Blood Glucose Meter System Analytical Performance Be Assessed?

Authors:  David A Simmons
Journal:  J Diabetes Sci Technol       Date:  2015-08-31

6.  Performance Evaluation of Three Blood Glucose Monitoring Systems Using ISO 15197: 2013 Accuracy Criteria, Consensus and Surveillance Error Grid Analyses, and Insulin Dosing Error Modeling in a Hospital Setting.

Authors:  José Luis Bedini; Jane F Wallace; Scott Pardo; Thorsten Petruschke
Journal:  J Diabetes Sci Technol       Date:  2015-10-07

7.  Analytical Performance Evaluation of Infopia Element™ Auto-coding Blood Glucose Monitoring System for Self-Monitoring of Blood Glucose.

Authors:  Hae-Il Park; Seong-Su Lee; Jang-Won Son; Hee-Sun Kwon; Sung Rae Kim; Hyojin Chae; Myungshin Kim; Yonggoo Kim; Soonjib Yoo
Journal:  J Clin Lab Anal       Date:  2016-04-13       Impact factor: 2.352

8.  Do We Need the Replacement of YSI 2300? A View from the Clinical Laboratory.

Authors:  Loukia Spanou; Konstantinos Makris
Journal:  J Diabetes Sci Technol       Date:  2021-05-17

9.  User Performance Evaluation of Four Blood Glucose Monitoring Systems Applying ISO 15197:2013 Accuracy Criteria and Calculation of Insulin Dosing Errors.

Authors:  Guido Freckmann; Nina Jendrike; Annette Baumstark; Stefan Pleus; Christina Liebing; Cornelia Haug
Journal:  Diabetes Ther       Date:  2018-03-03       Impact factor: 2.945

10.  Modeling Carbohydrate Counting Error in Type 1 Diabetes Management.

Authors:  Chiara Roversi; Martina Vettoretti; Simone Del Favero; Andrea Facchinetti; Giovanni Sparacino
Journal:  Diabetes Technol Ther       Date:  2020-09-24       Impact factor: 6.118

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.