Do We Need the Replacement of YSI 2300? A View from the Clinical Laboratory.

Loukia Spanou1, Konstantinos Makris2.   

Abstract

In this issue of Journal of Diabetes Science and Technology, Baumstark et al. evaluated the analytical performance of a bench-top laboratory glucose analyzer (SUPER-GL) intended for replacement for the YSI2300-STAT analyzer, that served for several decades as a comparator method in clinical and analytical studies of blood glucose monitoring systems (BGMS). The authors concluded that the SUPER-GL's overall performance is comparable to that of YSI2300-STAT, and has the potential to be a candidate comparator analyzer. However, the question is if we need to recommend as a "comparator method," a specific device, that measure glucose using the same analytical method with most BGMS. In this analysis we present our point of view hoping to generate a discussion on the necessity for such a replacement.

Entities:  

Keywords:  accuracy; blood glucose monitor system; self-monitoring of blood glucose

Mesh:

Substances:

Year:  2021        PMID: 33998317      PMCID: PMC9294573          DOI: 10.1177/19322968211007170

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  32 in total

1.  System accuracy evaluation of systems for point-of-care testing of blood glucose: a comparison of a patient-use system with six professional-use systems.

Authors:  Guido Freckmann; Christina Schmid; Stefan Pleus; Annette Baumstark; Manuela Link; Erhard Stolberg; Cornelia Haug; Jochen Sieber
Journal:  Clin Chem Lab Med       Date:  2014-07       Impact factor: 3.694

2.  Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs).

Authors:  Timothy S Bailey; Leslie J Klaff; Jane F Wallace; Carmine Greene; Scott Pardo; Bern Harrison; David A Simmons
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

Review 3.  What is blood glucose: can it be measured?

Authors:  J M Burrin; K G Alberti
Journal:  Diabet Med       Date:  1990 Mar-Apr       Impact factor: 4.359

4.  System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.

Authors:  Guido Freckmann; Christina Schmid; Annette Baumstark; Stefan Pleus; Manuela Link; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

5.  The YSI 2300 Analyzer Replacement Meeting Report.

Authors:  Julia Han; Lutz Heinemann; Barry H Ginsberg; Shridhara Alva; Matthias Appel; Stephan Bess; Kong Y Chen; Guido Freckmann; Dennis R Harris; Matthias Hartwig; Rolf Hinzmann; David Kerr; Jan Krouwer; Linda Morrow; James Nichols; Andreas Pfützner; Stefan Pleus; Mark Rice; David B Sacks; Kevin Schlueter; Hubert W Vesper; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2020-03-16

6.  Glucose meter performance criteria for tight glycemic control estimated by simulation modeling.

Authors:  Brad S Karon; James C Boyd; George G Klee
Journal:  Clin Chem       Date:  2010-05-28       Impact factor: 8.327

7.  Significant insulin dose errors may occur if blood glucose results are obtained from miscoded meters.

Authors:  Charles H Raine; Linda E Schrock; Steven V Edelman; Sunder Raj D Mudaliar; Weiping Zhong; Lois J Proud; Joan Lee Parkes
Journal:  J Diabetes Sci Technol       Date:  2007-03

Review 8.  Self-monitoring of blood glucose as part of the integral care of type 2 diabetes.

Authors:  Eleni I Boutati; Sotirios A Raptis
Journal:  Diabetes Care       Date:  2009-11       Impact factor: 19.112

9.  Impact of blood sample collection and processing methods on glucose levels in community outreach studies.

Authors:  Michael Turchiano; Cuong Nguyen; Arthur Fierman; Mark Lifshitz; Antonio Convit
Journal:  J Environ Public Health       Date:  2013-01-10

10.  System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015.

Authors:  Stefan Pleus; Annette Baumstark; Nina Jendrike; Jochen Mende; Manuela Link; Eva Zschornack; Cornelia Haug; Guido Freckmann
Journal:  BMJ Open Diabetes Res Care       Date:  2020-01
View more
  1 in total

1.  Comment on "Do We Need the Replacement of YSI 2300? A View from the Clinical Laboratory" by Spanou and Makris.

Authors:  Guido Freckmann; Annette Baumstark; Rolf Hinzmann; Cornelia Haug; Stefan Pleus
Journal:  J Diabetes Sci Technol       Date:  2021-05-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.