| Literature DB >> 22901963 |
Andri K Riau1, Neil Y S Tan, Romesh I Angunawela, Hla M Htoon, Shyam S Chaurasia, Jodhbir S Mehta.
Abstract
BACKGROUND: The rabbit is a common animal model for ophthalmic research, especially corneal research. Ocular structures grow rapidly during the early stages of life. It is unclear when the rabbit cornea becomes mature and stabilized. We investigated the changes of keratometry, refractive state and central corneal thickness (CCT) with age. In addition, we studied the intra- and inter-observer reproducibility of anterior chamber depth (ACD) and anterior chamber width (ACW) measurements in rabbits using anterior segment-optical coherence tomography (AS-OCT).Entities:
Mesh:
Year: 2012 PMID: 22901963 PMCID: PMC3514359 DOI: 10.1186/1746-6148-8-138
Source DB: PubMed Journal: BMC Vet Res ISSN: 1746-6148 Impact factor: 2.741
Figure 1Anterior segment OCT image of the anterior chamber in a rabbit eye. Anterior chamber depth (ACD) was measured from the posterior surface of the center of the cornea to the apex of the crystalline lens. Anterior chamber width (ACW) was measured from the scleral spurs in the nasal and temporal quadrants of the eye.
Mean keratometry, spherical equivalent and central corneal thickness of rabbits ranging from 1 month to 12 months old
| 1 | 50.50 ± 1.15 | 1.62 ± 1.41 | 341 ± 14 |
| 2 | 46.52 ± 0.73 | 2.13 ± 1.15 | 356 ± 11 |
| 3 | 45.52 ± 0.71 | 2.28 ± 0.78 | 366 ± 11 |
| 4 | 44.89 ± 0.69 | 2.30 ± 0.80 | 374 ± 11 |
| 5 | 43.56 ± 0.93 | 2.33 ± 0.77 | 388 ± 17 |
| 6 | 42.61 ± 0.90 | 2.59 ± 0.78 | 391 ± 16 |
| 7 | 42.34 ± 0.69 | 2.67 ± 0.99 | 401 ± 15 |
| 8 | 41.88 ± 0.79 | 2.87 ± 0.45 | 403 ± 14 |
| 9 | 41.30 ± 1.37 | 3.09 ± 0.69 | 401 ± 14 |
| 10 | 41.25 ± 0.78 | 3.09 ± 0.62 | 404 ± 14 |
| 11 | 40.77 ± 0.91 | 3.18 ± 0.63 | 404 ± 11 |
| 12 | 40.66 ± 1.05 | 3.13 ± 0.60 | 404 ± 12 |
*D = Diopter.
**CCT = central corneal thickness.
Figure 2Age-related changes in body weight (A), corneal curvature (B), refractive state (C) and central corneal thickness (D). Error bars represent standard deviation of the mean value.
Inter-observer mean anterior chamber depth and anterior chamber width of rabbit eyes measured by Visante AS-OCT
| | | ||||||
|---|---|---|---|---|---|---|---|
| Mean ACD† (mm) | 2.34 ± 0.24 | 2.36 ± 0.26 | 0.848 | 0.987 | −0.014 (−0.033 to 0.005) | 0.076 (0.042 to 0.109) | −0.104 (−0.138 to −0.070) |
| Mean ACW‡ (mm) | 13.70 ± 0.71 | 13.29 ± 0.84 | 0.073 | 0.962 | 0.414 (0.308 to 0.520) | 0.907 (0.723 to 1.09) | −0.079 (−0.263 to 0.105) |
*Based on observer 1 - observer 2 values.
†ACD = anterior chamber depth.
‡ACW = anterior chamber width.
CI = confidence interval; LoA = limits of agreement.
Figure 3Bland-Altman plots for observer 1 and observer 2 comparing measurements of anterior chamber depth (A) and anterior chamber width (B). The horizontal lines represent the mean and 95% limit of agreement (LoA).
Intra-observer variability of anterior chamber depth and anterior chamber width of rabbit eyes measured by Visante AS-OCT
| | | ||||||
|---|---|---|---|---|---|---|---|
| Mean ACD† (mm) | | | | | | | |
| Observer 1 | 2.34 ± 0.25 | 2.34 ± 0.25 | 0.993 | 0.997 | 0.001 (−0.011 to 0.013) | 0.039 (0.017 to 0.060) | −0.037 (−0.058 to −0.015) |
| Observer 2 | 2.36 ± 0.27 | 2.35 ± 0.27 | 0.958 | 0.990 | 0.006 (−0.009 to 0.020) | 0.051 (0.025 to 0.077) | −0.039 (−0.065 to −0.014) |
| Mean ACW‡ (mm) | | | | | | | |
| Observer 1 | 13.73 ± 0.72 | 13.68 ± 0.73 | 0.870 | 0.996 | 0.049 (−0.015 to 0.113) | 0.248 (0.134 to 0.361) | −0.149 (−0.262 to −0.036) |
| Observer 2 | 13.32 ± 0.85 | 13.25 ± 0.88 | 0.850 | 0.982 | 0.067 (−0.038 to 0.173) | 0.392 (0.207 to 0.577) | −0.257 (−0.442 to −0.072) |
*Based on measurement 1 - measurement 2 values.
†ACD = anterior chamber depth.
‡ACW = anterior chamber width.
CI = confidence interval; LoA = limits of agreement.
Figure 4Bland-Altman plots showing intra-observer agreement on measurements of anterior chamber depth (ACD) and anterior chamber width (ACW). (A) Repeated ACD measurements made by observer 1. (B) Repeated ACW measurements made by observer 1. (C) Repeated ACD measurements made by observer 2. (D) Repeated ACW measurements made by observer 2. The horizontal lines represent the mean and 95% limit of agreement (LoA).