OBJECTIVES: The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone. METHODS: Unenhanced chest CT images of 42 patients acquired with ULD-CT were compared with images obtained with SDD-CT or LDD-CT in the same examination. Noise measurements and image quality, based on conspicuity of chest lesions on all CT data sets were assessed on a five-point scale. RESULTS: The radiation dose of ULD-CT was 0.16 ± 0.006 mSv compared with 11.2 ± 2.7 mSv for SDD-CT (P < 0.0001) and 2.7 ± 0.9 mSv for LDD-CT. Image quality of ULD-CT increased significantly when using MBIR compared with FBP or ASIR (P < 0.001). ULD-CT reconstructed with MBIR enabled to detect as many non-calcified pulmonary nodules as seen on SDD-CT or LDD-CT. However, image quality of ULD-CT was clearly inferior for characterisation of ground glass opacities or emphysema. CONCLUSION: Model-based iterative reconstruction allows detection of pulmonary nodules with ULD-CT with radiation exposure in the range of a posterior to anterior (PA) and lateral chest X-ray.
OBJECTIVES: The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone. METHODS: Unenhanced chest CT images of 42 patients acquired with ULD-CT were compared with images obtained with SDD-CT or LDD-CT in the same examination. Noise measurements and image quality, based on conspicuity of chest lesions on all CT data sets were assessed on a five-point scale. RESULTS: The radiation dose of ULD-CT was 0.16 ± 0.006 mSv compared with 11.2 ± 2.7 mSv for SDD-CT (P < 0.0001) and 2.7 ± 0.9 mSv for LDD-CT. Image quality of ULD-CT increased significantly when using MBIR compared with FBP or ASIR (P < 0.001). ULD-CT reconstructed with MBIR enabled to detect as many non-calcified pulmonary nodules as seen on SDD-CT or LDD-CT. However, image quality of ULD-CT was clearly inferior for characterisation of ground glass opacities or emphysema. CONCLUSION: Model-based iterative reconstruction allows detection of pulmonary nodules with ULD-CT with radiation exposure in the range of a posterior to anterior (PA) and lateral chest X-ray.
Authors: David M Hansell; Alexander A Bankier; Heber MacMahon; Theresa C McLoud; Nestor L Müller; Jacques Remy Journal: Radiology Date: 2008-01-14 Impact factor: 11.105
Authors: Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard Journal: Radiology Date: 2011-03-08 Impact factor: 11.105
Authors: Klaus Bacher; Peter Smeets; Kris Bonnarens; An De Hauwere; Koenraad Verstraete; Hubert Thierens Journal: AJR Am J Roentgenol Date: 2003-10 Impact factor: 3.959
Authors: Adrian Huber; Julia Landau; Lukas Ebner; Yanik Bütikofer; Lars Leidolt; Barbara Brela; Michelle May; Johannes Heverhagen; Andreas Christe Journal: Eur Radiol Date: 2016-01-26 Impact factor: 5.315
Authors: N Sakai; H Yabuuchi; M Kondo; Y Matsuo; T Kamitani; M Nagao; M Jinnouchi; M Yonezawa; T Kojima; Y Yano; H Honda Journal: Br J Radiol Date: 2015-07-08 Impact factor: 3.039
Authors: Cristiano Rampinelli; Daniela Origgi; Vittoria Vecchi; Luigi Funicelli; Sara Raimondi; Paul Deak; Massimo Bellomi Journal: Radiol Med Date: 2015-02-06 Impact factor: 3.469