Low-dose CT screening using hybrid iterative reconstruction: confidence ratings of diagnoses of simulated lesions other than lung cancer.

N Sakai1, H Yabuuchi1, M Kondo2, Y Matsuo3, T Kamitani3, M Nagao3, M Jinnouchi3, M Yonezawa3, T Kojima1, Y Yano1, H Honda3.   

Abstract

OBJECTIVE: To evaluate the confidence ratings of diagnoses of simulated lesions other than lung cancer on low-dose screening CT with hybrid iterative reconstruction (IR).
METHODS: Simulated lesions (emphysema, mediastinal masses and interstitial pneumonia) in a chest phantom were scanned by a 320-row area detector CT. The scans were performed by 64-row and 160-row helical scans at various dose levels and were reconstructed by filtered back projection (FBP) and IR. Emphysema, honeycombing and reticular opacity were visually scored on a four-point scale by six thoracic radiologists. The ground-glass opacity as a percentage of total lung volume (%GGO), CT value and contrast-to-noise ratio (CNR) of mediastinal masses were calculated. These scores and values were compared between FBP and IR. Wilcoxon's signed-rank test was used (p < 0.05). Interobserver agreements were evaluated by κ statistics.
RESULTS: There were no significant differences in visual assessment. Interobserver agreement was almost perfect. CT values were almost equivalent between FBP and IR, whereas CNR with IR was significantly higher than that with FBP. %GGO significantly increased at low-dose levels with FBP; however, IR suppressed the elevation.
CONCLUSION: The confidence ratings of diagnoses of simulated lesions other than lung cancer on low-dose CT screening were not degraded with hybrid IR compared with FBP. ADVANCES IN KNOWLEDGE: Hybrid IR did not degrade the confidence ratings of diagnoses on visual assessment and differential diagnoses based on CT value of mediastinal masses, and it showed the advantage of higher GGO conspicuity at low-dose level. Radiologists can analyse images of hybrid IR alone on low-dose CT screening for lung cancer.

Entities:  

Mesh:

Year:  2015        PMID: 26153902      PMCID: PMC4743574          DOI: 10.1259/bjr.20150159

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  25 in total

1.  Measurement of observer agreement.

Authors:  Harold L Kundel; Marcia Polansky
Journal:  Radiology       Date:  2003-06-20       Impact factor: 11.105

2.  Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography.

Authors:  T M Bernhardt; D Otto; G Reichel; K Ludwig; S Seifert; S Kropf; U Rapp-Bernhardt
Journal:  Radiology       Date:  1999-11       Impact factor: 11.105

3.  Adaptive iterative dose reduction using 3D processing for reduced- and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings.

Authors:  Yoshiharu Ohno; Daisuke Takenaka; Tomonori Kanda; Takeshi Yoshikawa; Sumiaki Matsumoto; Naoki Sugihara; Kazuro Sugimura
Journal:  AJR Am J Roentgenol       Date:  2012-10       Impact factor: 3.959

4.  Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms.

Authors:  Samuel Richard; Daniela B Husarik; Girijesh Yadava; Simon N Murphy; Ehsan Samei
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

5.  Evaluation of the extent of ground-glass opacity on high-resolution CT in patients with interstitial pneumonia associated with systemic sclerosis: comparison between quantitative and qualitative analysis.

Authors:  H Yabuuchi; Y Matsuo; H Tsukamoto; T Horiuchi; S Sunami; T Kamitani; M Jinnouchi; M Nagao; K Akashi; H Honda
Journal:  Clin Radiol       Date:  2014-05-10       Impact factor: 2.350

6.  Detectability of simulated interstitial pneumonia on chest radiographs: comparison between irradiation side sampling indirect flat-panel detector and computed radiography.

Authors:  Y Yano; H Yabuuchi; A Kairada; N Tanaka; J Morishita; T Akasaka; Y Matsuo; T Kamitani; Y Yamasaki; M Nagao; M Sasaki
Journal:  Br J Radiol       Date:  2014-05-29       Impact factor: 3.039

7.  Radiation exposure and image quality in chest CT examinations.

Authors:  J G Ravenel; E M Scalzetti; W Huda; W Garrisi
Journal:  AJR Am J Roentgenol       Date:  2001-08       Impact factor: 3.959

8.  CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT.

Authors:  Alban Gervaise; Benoît Osemont; Sophie Lecocq; Alain Noel; Emilien Micard; Jacques Felblinger; Alain Blum
Journal:  Eur Radiol       Date:  2011-09-17       Impact factor: 5.315

9.  Visual assessment of early emphysema and interstitial abnormalities on CT is useful in lung cancer risk analysis.

Authors:  Mathilde M W Wille; Laura H Thomsen; Jens Petersen; Marleen de Bruijne; Asger Dirksen; Jesper H Pedersen; Saher B Shaker
Journal:  Eur Radiol       Date:  2015-05-09       Impact factor: 5.315

10.  Emphysema quantification by low-dose CT: potential impact of adaptive iterative dose reduction using 3D processing.

Authors:  Mizuho Nishio; Sumiaki Matsumoto; Yoshiharu Ohno; Naoki Sugihara; Hiroyasu Inokawa; Takeshi Yoshikawa; Kazuro Sugimura
Journal:  AJR Am J Roentgenol       Date:  2012-09       Impact factor: 3.959

View more
  1 in total

Review 1.  Low-dose CT in COVID-19 outbreak: radiation safety, image wisely, and image gently pledge.

Authors:  Salar Tofighi; Saeideh Najafi; Sean K Johnston; Ali Gholamrezanezhad
Journal:  Emerg Radiol       Date:  2020-05-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.