Literature DB >> 22753021

Time-resolved dual-station calf-foot three-dimensional bolus chase MR angiography with fluoroscopic tracking.

Casey P Johnson1, Eric A Borisch, James F Glockner, Phillip M Young, Stephen J Riederer.   

Abstract

PURPOSE: To refine, adapt, and evaluate the technical aspects of fluoroscopic tracking for generating dual-station high-spatial-resolution MR angiograms of the calves and feet using a single injection of contrast material.
MATERIALS AND METHODS: Nine subjects (seven healthy volunteers followed by two patients) were imaged using a two-station calf-foot three-dimensional time-resolved bolus chase MR angiography protocol which provided <1.0 mm(3) spatial resolution throughout and 2.5- and 6.6-s frame times at the calf and foot stations, respectively. Real-time reconstruction of calf station time frames allowed visually guided triggering of table advance to the foot station. The studies were independently read and scored by two radiologists in six image quality categories.
RESULTS: On average, overall diagnostic quality at the calf and foot stations was good-to-excellent, the calf arteries and all but the smallest foot arteries had good-to-excellent signal and sharpness, artifact and venous contamination were minor, and signal continuity across the inter-station interface was good.
CONCLUSION: The feasibility of fluoroscopic tracking has been demonstrated as an efficient approach for high spatiotemporal imaging of the arteries of the calves and feet with good-to-excellent diagnostic quality and low degrading venous contamination.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22753021      PMCID: PMC3465643          DOI: 10.1002/jmri.23739

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  29 in total

1.  Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies.

Authors:  S J Riederer; M A Bernstein; J F Breen; R F Busse; R L Ehman; S B Fain; T C Hulshizer; J Huston; B F King; D G Kruger; P J Rossman; S Shah
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

2.  [Time-resolved contrast-enhanced MR angiography of the lower limbs: solving the problem of venous overlap].

Authors:  D Floery; F A Fellner; C Fellner; C M Ginthoer; M Uder; L Pallwein-Prettner; J Roeper-Kelmayr; A Dirisamer
Journal:  Rofo       Date:  2010-10-11

3.  Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.

Authors:  J P Earls; N M Rofsky; D R DeCorato; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

4.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

5.  MR fluoroscopy: technical feasibility.

Authors:  S J Riederer; T Tasciyan; F Farzaneh; J N Lee; R C Wright; R J Herfkens
Journal:  Magn Reson Med       Date:  1988-09       Impact factor: 4.668

Review 6.  High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet.

Authors:  Clifton R Haider; Stephen J Riederer; Eric A Borisch; James F Glockner; Roger C Grimm; Thomas C Hulshizer; Thanila A Macedo; Petrice M Mostardi; Phillip J Rossman; Terri J Vrtiska; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2011-07       Impact factor: 4.813

7.  Peripheral arterial occlusive disease: evaluation of a high spatial and temporal resolution 3-T MR protocol with a low total dose of gadolinium versus conventional angiography.

Authors:  Ulrike I Attenberger; Stefan Haneder; John N Morelli; Steffen J Diehl; Stefan O Schoenberg; Henrik J Michaely
Journal:  Radiology       Date:  2010-10-19       Impact factor: 11.105

8.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

9.  Contrast material travel times in patients undergoing peripheral MR angiography.

Authors:  Martin R Prince; Shalini G Chabra; Richard Watts; Catherine Z Chen; Priscilla A Winchester; Neil M Khilnani; David Trost; Harry A Bush; K Craig Kent; Yi Wang
Journal:  Radiology       Date:  2002-07       Impact factor: 11.105

10.  Highly accelerated first-pass contrast-enhanced magnetic resonance angiography of the peripheral vasculature: comparison of gadofosveset trisodium with gadopentetate dimeglumine contrast agents.

Authors:  Jeffrey H Maki; Maisie Wang; Gregory J Wilson; Matthew G Shutske; Tim Leiner
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

View more
  4 in total

1.  Three-station three-dimensional bolus-chase MR angiography with real-time fluoroscopic tracking.

Authors:  Casey P Johnson; Paul T Weavers; Eric A Borisch; Roger C Grimm; Thomas C Hulshizer; Christine C LaPlante; Phillip J Rossman; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2014-03-14       Impact factor: 11.105

2.  Acceleration apportionment: a method of improved 2D SENSE acceleration applied to 3D contrast-enhanced MR angiography.

Authors:  Paul T Weavers; Eric A Borisch; Casey P Johnson; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

3.  Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography.

Authors:  Eric G Stinson; Eric A Borisch; Casey P Johnson; Joshua D Trzasko; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2013-07-29       Impact factor: 4.813

4.  Improved receiver arrays and optimized parallel imaging accelerations applied to time-resolved 3D fluoroscopically tracked peripheral runoff CE-MRA.

Authors:  Paul T Weavers; Eric A Borisch; Tom C Hulshizer; Phillip J Rossman; Phillip M Young; Casey P Johnson; Jessica McKay; Christopher C Cline; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2015-10-31       Impact factor: 2.546

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.