Literature DB >> 10796943

Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies.

S J Riederer1, M A Bernstein, J F Breen, R F Busse, R L Ehman, S B Fain, T C Hulshizer, J Huston, B F King, D G Kruger, P J Rossman, S Shah.   

Abstract

Technical reliability was determined for triggering three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiography with MR fluoroscopy. Technical requirements for high reliability were also identified. Reliability was evaluated in 330 consecutive patient studies of the neck, thorax, abdomen, and pelvis. Contrast material arrival was detected fluoroscopically in 325 of the 330 studies (98.5%), and the 3D sequence was successfully triggered in 321 of 330 studies (97.3%). Fluoroscopic triggering of centrically encoded 3D MR angiographic acquisitions is a highly reliable means of obtaining 3D MR angiograms with high spatial resolution.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10796943     DOI: 10.1148/radiology.215.2.r00ma21584

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  14 in total

1.  [The significance of MR angiography for the diagnosis of carotid stenoses].

Authors:  H J Michaely; K A Herrmann; H Kramer; G Laub; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

Review 2.  MR angiography of the intracranial vessels: technical aspects and clinical applications.

Authors:  Ozkan Ozsarlak; Johan W Van Goethem; Menno Maes; Paul M Parizel
Journal:  Neuroradiology       Date:  2004-12-04       Impact factor: 2.804

Review 3.  Cross-sectional vascular imaging with CT and MR angiography.

Authors:  Hasan K Kabul; Klaus D Hagspiel
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

4.  Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV.

Authors:  Stephen J Riederer; Houchun Harry Hu; David G Kruger; Clifton R Haider; Norbert G Campeau; John Huston
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

5.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

6.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

Review 7.  Introduction to Cardiovascular Magnetic Resonance: Technical Principles and Clinical Applications.

Authors:  Wen-Yih Isaac Tseng; Mao-Yuan Marine Su; Yao-Hui Elton Tseng
Journal:  Acta Cardiol Sin       Date:  2016-03       Impact factor: 2.672

Review 8.  Congenital diseases of the thoracic aorta. Role of MRI and MRA.

Authors:  Vincenzo Russo; Matteo Renzulli; Cesare La Palombara; Rossella Fattori
Journal:  Eur Radiol       Date:  2005-10-26       Impact factor: 5.315

9.  Contrast-enhanced MR angiography of the abdomen with highly accelerated acquisition techniques.

Authors:  Petrice M Mostardi; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2011-09-07       Impact factor: 11.105

10.  CTA and 2D-3D post-processing: radiological signs of fibromuscular dysplasia of renal artery.

Authors:  Alberto Clemente; Veronica Macchi; Andrea Porzionato; Carla Stecco; Raffaele De Caro; Aldo Morra
Journal:  Surg Radiol Anat       Date:  2008-07-23       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.