PURPOSE: To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries.
MATERIALS AND METHODS: This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30-81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47-81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test.
RESULTS: Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories.
CONCLUSION: Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms. © RSNA, 2014.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24635676      PMCID: PMC4123738          DOI: 10.1148/radiol.14131603

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  33 in total

1.  Whole-body magnetic resonance angiography with additional steady-state acquisition of the infragenicular arteries in patients with peripheral arterial disease.

Authors:  Yousef W Nielsen; Jonas P Eiberg; Vibeke B Løgager; Sven Just; Torben V Schroeder; Henrik S Thomsen
Journal:  Cardiovasc Intervent Radiol       Date:  2009-12-03       Impact factor: 2.740

2.  Prospective comparison of cartesian acquisition with projection-like reconstruction magnetic resonance angiography with computed tomography angiography for evaluation of below-the-knee runoff.

Authors:  Phillip M Young; Petrice M Mostardi; James F Glockner; Terri R Vrtiska; Thanila Macedo; Clifton R Haider; Stephen J Riederer
Journal:  J Vasc Interv Radiol       Date:  2013-03       Impact factor: 3.464

3.  Subtractionless first-pass single contrast medium dose peripheral MR angiography using two-point Dixon fat suppression.

Authors:  Tim Leiner; Jesse Habets; Bastiaan Versluis; Liesbeth Geerts; Eveline Alberts; Niels Blanken; Jeroen Hendrikse; Evert-Jan Vonken; Holger Eggers
Journal:  Eur Radiol       Date:  2013-04-17       Impact factor: 5.315

4.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

5.  Sparse-CAPR: highly accelerated 4D CE-MRA with parallel imaging and nonconvex compressive sensing.

Authors:  Joshua D Trzasko; Clifton R Haider; Eric A Borisch; Norbert G Campeau; James F Glockner; Stephen J Riederer; Armando Manduca
Journal:  Magn Reson Med       Date:  2011-05-23       Impact factor: 4.668

6.  Peripheral arterial occlusive disease: evaluation of a high spatial and temporal resolution 3-T MR protocol with a low total dose of gadolinium versus conventional angiography.

Authors:  Ulrike I Attenberger; Stefan Haneder; John N Morelli; Steffen J Diehl; Stefan O Schoenberg; Henrik J Michaely
Journal:  Radiology       Date:  2010-10-19       Impact factor: 11.105

7.  Time-resolved dual-station calf-foot three-dimensional bolus chase MR angiography with fluoroscopic tracking.

Authors:  Casey P Johnson; Eric A Borisch; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2012-06-29       Impact factor: 4.813

8.  Highly accelerated first-pass contrast-enhanced magnetic resonance angiography of the peripheral vasculature: comparison of gadofosveset trisodium with gadopentetate dimeglumine contrast agents.

Authors:  Jeffrey H Maki; Maisie Wang; Gregory J Wilson; Matthew G Shutske; Tim Leiner
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

9.  Comparison of contrast-enhanced multi-station MR angiography and digital subtraction angiography of the lower extremity arterial disease.

Authors:  Mykhaylo Burbelko; Michael Augsten; Marc O Kalinowski; Johannes T Heverhagen
Journal:  J Magn Reson Imaging       Date:  2012-11-27       Impact factor: 4.813

10.  2D SENSE for faster 3D MRI.

Authors:  Markus Weiger; Klaas P Pruessmann; Peter Boesiger
Journal:  MAGMA       Date:  2002-03       Impact factor: 2.533

View more
  6 in total

1.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

Review 2.  Pediatric magnetic resonance angiography: to contrast or not to contrast.

Authors:  Erin K Opfer; Nathan S Artz; Grace S Mitchell; Sherwin S Chan
Journal:  Pediatr Radiol       Date:  2022-08-12

3.  Improved receiver arrays and optimized parallel imaging accelerations applied to time-resolved 3D fluoroscopically tracked peripheral runoff CE-MRA.

Authors:  Paul T Weavers; Eric A Borisch; Tom C Hulshizer; Phillip J Rossman; Phillip M Young; Casey P Johnson; Jessica McKay; Christopher C Cline; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2015-10-31       Impact factor: 2.546

4.  Dixon-type and subtraction-type contrast-enhanced magnetic resonance angiography: A theoretical and experimental comparison of SNR and CNR.

Authors:  Eric G Stinson; Joshua D Trzasko; Paul T Weavers; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-07-17       Impact factor: 4.668

5.  The impact of dual-source parallel radiofrequency transmission with patient-adaptive shimming on the cardiac magnetic resonance in children at 3.0 T.

Authors:  Haipeng Wang; Liyun Qiu; Guangbin Wang; Fei Gao; Haipeng Jia; Junyu Zhao; Weibo Chen; Cuiyan Wang; Bin Zhao
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

6.  Technical Aspects of Contrast-enhanced MR Angiography: Current Status and New Applications.

Authors:  Stephen J Riederer; Eric G Stinson; Paul T Weavers
Journal:  Magn Reson Med Sci       Date:  2017-08-31       Impact factor: 2.471

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.