OBJECTIVE: To provide evidence for the selection of an optimal cross-sectional reconstruction mode in spectral CT imaging of the abdomen, we compared the monochromatic images with polychromatic images. METHODS: Three phase-enhanced CT scans of the abdomen were recorded using the spectral imaging technique on 100 patients. Images were reconstructed using two modes: polychromatic and 70 keV monochromatic. The following variables were then compared: contrast-to-noise ratio (CNR) of the liver, spleen, gallbladder, kidney and pancreas, and the noise. Paired t-tests were used to compare differences between the two sets of images. Three experienced doctors graded the quality of the images with a five-point scale. The image quality scores were compared with a non-parametric rank sum test. RESULTS: Compared with polychromatic images, the 70 keV monochromatic mode images yielded significantly greater tissue-to-fat CNR and lower noise (p<0.001 for all comparisons). The image quality of the 70 keV monochromatic mode showed significantly better results than the polychromatic mode (p<0.001). CONCLUSIONS: In abdominal spectral CT imaging, 70 keV monochromatic mode reconstruction images were better than those reconstructed using the polychromatic mode. The monochromatic mode may become the routine reconstruction mode for cross-sectional images.
OBJECTIVE: To provide evidence for the selection of an optimal cross-sectional reconstruction mode in spectral CT imaging of the abdomen, we compared the monochromatic images with polychromatic images. METHODS: Three phase-enhanced CT scans of the abdomen were recorded using the spectral imaging technique on 100 patients. Images were reconstructed using two modes: polychromatic and 70 keV monochromatic. The following variables were then compared: contrast-to-noise ratio (CNR) of the liver, spleen, gallbladder, kidney and pancreas, and the noise. Paired t-tests were used to compare differences between the two sets of images. Three experienced doctors graded the quality of the images with a five-point scale. The image quality scores were compared with a non-parametric rank sum test. RESULTS: Compared with polychromatic images, the 70 keV monochromatic mode images yielded significantly greater tissue-to-fat CNR and lower noise (p<0.001 for all comparisons). The image quality of the 70 keV monochromatic mode showed significantly better results than the polychromatic mode (p<0.001). CONCLUSIONS: In abdominal spectral CT imaging, 70 keV monochromatic mode reconstruction images were better than those reconstructed using the polychromatic mode. The monochromatic mode may become the routine reconstruction mode for cross-sectional images.
Authors: C L Brown; R P Hartman; O P Dzyubak; N Takahashi; A Kawashima; C H McCollough; M R Bruesewitz; A M Primak; J G Fletcher Journal: Eur Radiol Date: 2009-01-20 Impact factor: 5.315
Authors: N Schramm; M Schlemmer; E Englhart; M Hittinger; C Becker; M Reiser; F Berger Journal: Curr Pharm Biotechnol Date: 2011-04 Impact factor: 2.837
Authors: Benjamin M Yeh; John A Shepherd; Zhen J Wang; Hui Seong Teh; Robert P Hartman; Sven Prevrhal Journal: AJR Am J Roentgenol Date: 2009-07 Impact factor: 3.959
Authors: G Jay Hanson; Gregory J Michalak; Robert Childs; Brian McCollough; Anil N Kurup; David M Hough; Judson M Frye; Jeff L Fidler; Sudhakar K Venkatesh; Shuai Leng; Lifeng Yu; Ahmed F Halaweish; W Scott Harmsen; Cynthia H McCollough; J G Fletcher Journal: Abdom Radiol (NY) Date: 2018-06
Authors: Hyo-Jin Kang; Jeong Min Lee; Sang Min Lee; Hyun Kyung Yang; Ri Hyeon Kim; Ju Gang Nam; Aruna Karnawat; Joon Koo Han Journal: BMC Med Imaging Date: 2019-08-28 Impact factor: 1.930