Literature DB >> 432276

Correction for beam hardening in computed tomography.

G T Herman.   

Abstract

We investigate how one can estimate from the total attenuation, p, of a polyenergetic X-ray beam what the total attenuation, m, of a monoenergetic beam would have been along the same ray. We find that for beams with typical diagnostic X-ray spectra passing through the human body one can find a simple function f such that f(p) is a sufficiently close estimate of m to allow good reconstructions. We also find that m cannot be accurately estimated from p based on the assumption that the human body consists of water alone. Our results are demonstrated by reconstructions of a mathematical model of a cross-section of the human thorax. This article is self-contained and includes in its Appendices a detailed discussion of the mathematical nature of the problem of bean hardening in computed tomography.

Entities:  

Mesh:

Year:  1979        PMID: 432276     DOI: 10.1088/0031-9155/24/1/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Which should be the routine cross-sectional reconstruction mode in spectral CT imaging: monochromatic or polychromatic?

Authors:  Y Cui; S-Y Gao; Z-L Wang; X-T Li; Y-S Sun; L Tang; X-P Zhang
Journal:  Br J Radiol       Date:  2012-06-20       Impact factor: 3.039

Review 2.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

3.  Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements.

Authors:  Thomas Blumensath; Richard Boardman
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

4.  Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer.

Authors:  H Kwon; K S Kim; Y M Chun; H-G Wu; J N K Carlson; J M Park; J-I Kim
Journal:  Br J Radiol       Date:  2015-05-20       Impact factor: 3.039

5.  Development and validation of a segmentation-free polyenergetic algorithm for dynamic perfusion computed tomography.

Authors:  Yuan Lin; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-08-23

6.  Perimortem fractures in Lucy suggest mortality from fall out of tall tree.

Authors:  John Kappelman; Richard A Ketcham; Stephen Pearce; Lawrence Todd; Wiley Akins; Matthew W Colbert; Mulugeta Feseha; Jessica A Maisano; Adrienne Witzel
Journal:  Nature       Date:  2016-08-29       Impact factor: 49.962

7.  High-kVp Assisted Metal Artifact Reduction for X-ray Computed Tomography.

Authors:  Yan Xi; Yannan Jin; Bruno De Man; Ge Wang
Journal:  IEEE Access       Date:  2016-09-16       Impact factor: 3.367

8.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

9.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

10.  Cone beam micro-CT system for small animal imaging and performance evaluation.

Authors:  Shouping Zhu; Jie Tian; Guorui Yan; Chenghu Qin; Jinchao Feng
Journal:  Int J Biomed Imaging       Date:  2009-09-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.