Literature DB >> 3708262

Tissue analysis by dual-energy computed tomography.

D J Hawkes, D F Jackson, R P Parker.   

Abstract

A straightforward method of tissue analysis from dual-energy computed tomography (CT) is presented which does not rely on previous inaccurate or incorrect formulations of the X-ray attenuation coefficient. The attenuation coefficients of tissue and bone were represented by a mixture of two reference materials. For convenience, water and calcium chloride were chosen. After careful calibration of the CT scanner, a dual-energy CT scan yields the water and calcium chloride in units of kg/kg multiplied by the specific gravity of the tissue. For an error of +/- 2 HU on dual-energy scans at 140 kVp and 87 kVp on an EMI CT5005 general-purpose scanner, the error on the calcium chloride coefficients is +/- 0.004 kg/kg. Fat concentrations greater than 25% by weight may be detected when the coefficients are averaged over at least 200 pixels. Bone mineral content could be measured with a precision of 0.01 (in units of kg/kg multiplied by specific gravity) for averaging regions of 24 pixels. Iodine concentrations in tissue can be deduced if water and iodine are chosen as the reference materials. Clinical examples are presented to illustrate the technique for scans of both the head and the abdomen.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3708262     DOI: 10.1259/0007-1285-59-702-537

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Which should be the routine cross-sectional reconstruction mode in spectral CT imaging: monochromatic or polychromatic?

Authors:  Y Cui; S-Y Gao; Z-L Wang; X-T Li; Y-S Sun; L Tang; X-P Zhang
Journal:  Br J Radiol       Date:  2012-06-20       Impact factor: 3.039

2.  Spectral CT imaging as a new quantitative tool? Assessment of perfusion defects of pulmonary parenchyma in patients with lung cancer.

Authors:  Ying-Shi Sun; Xiao-Yan Zhang; Yong Cui; Lei Tang; Xiao-Ting Li; Ying Chen; Xiao-Peng Zhang
Journal:  Chin J Cancer Res       Date:  2013-12       Impact factor: 5.087

3.  Detection of calcium pyrophosphate dihydrate crystals in knee meniscus by dual-energy computed tomography.

Authors:  Hidenori Tanikawa; Ryo Ogawa; Kazunari Okuma; Kengo Harato; Yasuo Niki; Shu Kobayashi; Takeo Nagura
Journal:  J Orthop Surg Res       Date:  2018-04-05       Impact factor: 2.359

4.  Gemstone spectral imaging in lung cancer: A preliminary study.

Authors:  Yulin Jia; Xigang Xiao; Qiulian Sun; Huijie Jiang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

5.  Quantitative contrast enhanced dual energy CT to predict avascular necrosis: a feasibility study of proximal humerus fractures.

Authors:  Kevin B Hoover; Alexandria O Starks; Valentina Robila; Daniel L Riddle
Journal:  BMC Med Imaging       Date:  2021-12-11       Impact factor: 1.930

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.