Literature DB >> 22704826

Micromechanics of the human vertebral body for forward flexion.

Haisheng Yang1, Shashank Nawathe, Aaron J Fields, Tony M Keaveny.   

Abstract

To provide mechanistic insight into the etiology of osteoporotic wedge fractures, we investigated the spatial distribution of tissue at the highest risk of initial failure within the human vertebral body for both forward flexion and uniform compression loading conditions. Micro-CT-based linear elastic finite element analysis was used to virtually load 22 human T9 vertebral bodies in either 5° of forward flexion or uniform compression; we also ran analyses replacing the simulated compliant disc (E=8 MPa) with stiff polymethylmethacrylate (PMMA, E=2500 MPa). As expected, we found that, compared to uniform compression, forward flexion increased the overall endplate axial load on the anterior half of the vertebra and shifted the spatial distribution of high-risk tissue within the vertebra towards the anterior aspect of the vertebral body. However, despite that shift, the high-risk tissue remained primarily within the central regions of the trabecular bone and endplates, and forward flexion only slightly altered the ratio of cortical-to-trabecular load sharing at the mid-vertebral level (mean±SD for n=22: 41.3±7.4% compression; 44.1±8.2% forward flexion). When the compliant disc was replaced with PMMA, the anterior shift of high-risk tissue was much more severe. We conclude that, for a compliant disc, a moderate degree of forward flexion does not appreciably alter the spatial distribution of stress within the vertebral body.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22704826      PMCID: PMC3415303          DOI: 10.1016/j.jbiomech.2012.05.044

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  50 in total

1.  Introduction: disc degeneration: summary.

Authors:  Howard S An; Paul A Anderson; Victor M Haughton; James C Iatridis; James D Kang; Jeffrey C Lotz; Raghu N Natarajan; Theodore R Oegema; Peter Roughley; Lori A Setton; Jill P Urban; Tapio Videman; Gunnar B J Andersson; James N Weinstein
Journal:  Spine (Phila Pa 1976)       Date:  2004-12-01       Impact factor: 3.468

2.  Development of residual strains in human vertebral trabecular bone after prolonged static and cyclic loading at low load levels.

Authors:  Ei Yamamoto; R Paul Crawford; Deva D Chan; Tony M Keaveny
Journal:  J Biomech       Date:  2005-07-21       Impact factor: 2.712

3.  Cortical and trabecular load sharing in the human vertebral body.

Authors:  Senthil K Eswaran; Atul Gupta; Mark F Adams; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2005-11-07       Impact factor: 6.741

4.  Mechanical efficacy of vertebroplasty: influence of cement type, BMD, fracture severity, and disc degeneration.

Authors:  Jin Luo; Daniel M Skrzypiec; Phillip Pollintine; Michael A Adams; Deborah J Annesley-Williams; Patricia Dolan
Journal:  Bone       Date:  2007-01-16       Impact factor: 4.398

5.  Degeneration affects the anisotropic and nonlinear behaviors of human anulus fibrosus in compression.

Authors:  J C Iatridis; L A Setton; R J Foster; B A Rawlins; M Weidenbaum; V C Mow
Journal:  J Biomech       Date:  1998-06       Impact factor: 2.712

6.  Intervertebral disc degeneration can predispose to anterior vertebral fractures in the thoracolumbar spine.

Authors:  Michael A Adams; Phillip Pollintine; Jon H Tobias; Glenn K Wakley; Patricia Dolan
Journal:  J Bone Miner Res       Date:  2006-09       Impact factor: 6.741

7.  Mechanical and morphological variation of the human lumbar vertebral cortical and trabecular bone.

Authors:  M E Roy; J Y Rho; T Y Tsui; N D Evans; G M Pharr
Journal:  J Biomed Mater Res       Date:  1999-02

8.  Can vertebroplasty restore normal load-bearing to fractured vertebrae?

Authors:  Najma Farooq; Jonathan C Park; Phillip Pollintine; Deborah J Annesley-Williams; Patricia Dolan
Journal:  Spine (Phila Pa 1976)       Date:  2005-08-01       Impact factor: 3.468

9.  Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method.

Authors:  Antonius Rohlmann; Thomas Zander; Hendrik Schmidt; Hans-Joachim Wilke; Georg Bergmann
Journal:  J Biomech       Date:  2005-09-29       Impact factor: 2.712

10.  Influence of bone volume fraction and architecture on computed large-deformation failure mechanisms in human trabecular bone.

Authors:  Grant Bevill; Senthil K Eswaran; Atul Gupta; Panayiotis Papadopoulos; Tony M Keaveny
Journal:  Bone       Date:  2006-08-10       Impact factor: 4.398

View more
  6 in total

1.  The examination of stress shielding in a finite element lumbar spine inclusive of the thoracolumbar fascia.

Authors:  Emily Newell; Mark Driscoll
Journal:  Med Biol Eng Comput       Date:  2021-07-17       Impact factor: 2.602

2.  Does spinopelvic alignment affect the union status in thoracolumbar osteoporotic vertebral compression fracture?

Authors:  Akira Iwata; Masahiro Kanayama; Fumihiro Oha; Tomoyuki Hashimoto; Norimasa Iwasaki
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-08-30

3.  Quantitative, 3D Visualization of the Initiation and Progression of Vertebral Fractures Under Compression and Anterior Flexion.

Authors:  Timothy M Jackman; Amira I Hussein; Cameron Curtiss; Paul M Fein; Anderson Camp; Lidia De Barros; Elise F Morgan
Journal:  J Bone Miner Res       Date:  2015-12-24       Impact factor: 6.741

4.  Effective modulus of the human intervertebral disc and its effect on vertebral bone stress.

Authors:  Haisheng Yang; Michael G Jekir; Maxwell W Davis; Tony M Keaveny
Journal:  J Biomech       Date:  2016-02-27       Impact factor: 2.712

5.  Anatomically and Biomechanically Relevant Monolithic Total Disc Replacement Made of 3D-Printed Thermoplastic Polyurethane.

Authors:  Muhammad Hanif Nadhif; Muhammad Maulana Ghiffary; Muhammad Irsyad; Nuzli Fahdia Mazfufah; Fakhira Nurhaliza; Siti Fauziyah Rahman; Ahmad Jabir Rahyussalim; Tri Kurniawati
Journal:  Polymers (Basel)       Date:  2022-10-04       Impact factor: 4.967

6.  Load-transfer in the human vertebral body following lumbar total disc arthroplasty: Effects of implant size and stiffness in axial compression and forward flexion.

Authors:  Noah B Bonnheim; Tony M Keaveny
Journal:  JOR Spine       Date:  2020-01-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.