Literature DB >> 16418787

Cortical and trabecular load sharing in the human vertebral body.

Senthil K Eswaran1, Atul Gupta, Mark F Adams, Tony M Keaveny.   

Abstract

UNLABELLED: The biomechanical role of the vertebral cortical shell remains poorly understood. Using high-resolution finite element modeling of a cohort of elderly vertebrae, we found that the biomechanical role of the shell can be substantial and that the load sharing between the cortical and trabecular bone is complex. As a result, a more integrative measure of the trabecular and cortical bone should improve noninvasive assessment of fracture risk and treatments.
INTRODUCTION: A fundamental but poorly understood issue in the assessment of both osteoporotic vertebral fracture risk and effects of treatment is the role of the trabecular bone and cortical shell in the load-carrying capacity of the vertebral body.
MATERIALS AND METHODS: High-resolution microCT-based finite element models were developed for 13 elderly human vertebrae (age range: 54-87 years; 74.6 +/- 9.4 years), and parameter studies-with and without endplates-were performed to determine the role of the shell versus trabecular bone and the effect of model assumptions.
RESULTS: Across vertebrae, whereas the average thickness of the cortical shell was only 0.38 +/- 0.06 mm, the shell mass fraction (shell mass/total bone mass)-not including the endplates-ranged from 0.21 to 0.39. The maximum load fraction taken by the shell varied from 0.38 to 0.54 across vertebrae and occurred at the narrowest section. The maximum load fraction taken by the trabecular bone varied from 0.76 to 0.89 across vertebrae and occurred near the endplates. Neither the maximum shell load fraction nor the maximum trabecular load fraction depended on any of the densitometric or morphologic properties of the vertebra, indicating the complex nature of the load sharing mechanism. The variation of the shell load-carrying capacity across vertebrae was significantly altered by the removal of endplates, although these models captured the overall trend within a vertebra.
CONCLUSIONS: The biomechanical role of the thin cortical shell in the vertebral body can be substantial, being about 45% at the midtransverse section but as low as 15% close to the endplates. As a result of the complexity of load sharing, sampling of only midsection trabecular bone as a strength surrogate misses important biomechanical information. A more integrative approach that combines the structural role of both cortical and trabecular bone should improve noninvasive assessment of vertebral bone strength in vivo.

Entities:  

Mesh:

Year:  2005        PMID: 16418787     DOI: 10.1359/jbmr.2006.21.2.307

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  75 in total

1.  QCT measures of bone strength at the thoracic and lumbar spine: the Framingham Study.

Authors:  Elizabeth J Samelson; Blaine A Christiansen; Serkalem Demissie; Kerry E Broe; Qiong Louie-Gao; L Adrienne Cupples; Benjamin J Roberts; Rajaram Manoharam; John D'Agostino; Thomas Lang; Douglas P Kiel; Mary L Bouxsein
Journal:  J Bone Miner Res       Date:  2012-03       Impact factor: 6.741

2.  The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty.

Authors:  Michael Kinzl; Lorin M Benneker; Andreas Boger; Philippe K Zysset; Dieter H Pahr
Journal:  Eur Spine J       Date:  2011-12-15       Impact factor: 3.134

Review 3.  Functional interactions among morphologic and tissue quality traits define bone quality.

Authors:  Karl J Jepsen
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  Does thoracic or lumbar spine bone architecture predict vertebral failure strength more accurately than density?

Authors:  E-M Lochmüller; K Pöschl; L Würstlin; M Matsuura; R Müller; T M Link; F Eckstein
Journal:  Osteoporos Int       Date:  2007-10-03       Impact factor: 4.507

5.  Interaction between playing golf and HRT on vertebral bone properties in post-menopausal women measured by QCT.

Authors:  P Eser; J Cook; J Black; R Iles; R M Daly; R Ptasznik; S L Bass
Journal:  Osteoporos Int       Date:  2007-10-16       Impact factor: 4.507

6.  Locations of bone tissue at high risk of initial failure during compressive loading of the human vertebral body.

Authors:  Senthil K Eswaran; Atul Gupta; Tony M Keaveny
Journal:  Bone       Date:  2007-06-19       Impact factor: 4.398

7.  Variation of trabecular microarchitectural parameters in cranial, caudal and mid-vertebral regions of the ovine L3 vertebra.

Authors:  Oran D Kennedy; Orlaith Brennan; Susan M Rackard; Fergal J O'Brien; David Taylor; T Clive Lee
Journal:  J Anat       Date:  2009-05       Impact factor: 2.610

8.  Region-dependent bone loss in the lumbar spine following femoral fracture in mice.

Authors:  Erica V Ely; Benjamin Osipov; Armaun J Emami; Blaine A Christiansen
Journal:  Bone       Date:  2020-07-29       Impact factor: 4.398

Review 9.  Post-yield and failure properties of cortical bone.

Authors:  Uwe Wolfram; Jakob Schwiedrzik
Journal:  Bonekey Rep       Date:  2016-08-24

10.  Rapid cortical bone loss in patients with chronic kidney disease.

Authors:  Thomas L Nickolas; Emily M Stein; Elzbieta Dworakowski; Kyle K Nishiyama; Mafo Komandah-Kosseh; Chiyuan A Zhang; Donald J McMahon; Xiaowei S Liu; Stephanie Boutroy; Serge Cremers; Elizabeth Shane
Journal:  J Bone Miner Res       Date:  2013-08       Impact factor: 6.741