Literature DB >> 23526082

Assessment of image quality and radiation dose of prospectively ECG-triggered adaptive dual-source coronary computed tomography angiography (cCTA) with arrhythmia rejection algorithm in systole versus diastole: a retrospective cohort study.

Ashley M Lee1, Jonathan Beaudoin, Leif-Christopher Engel, Manavjot S Sidhu, Suhny Abbara, Thomas J Brady, Udo Hoffmann, Brian B Ghoshhajra.   

Abstract

In this study, we sought to evaluate the image quality and effective radiation dose of prospectively ECG-triggered adaptive systolic (PTA-systolic) dual-source CTA versus prospectively triggered adaptive diastolic (PTA-diastolic) dual-source CTA in patients of unselected heart rate and rhythm. This retrospective cohort study consisted of 41 PTA-systolic and 41 matched PTA-diastolic CTA patients whom underwent clinically indicated 128-slice dual source CTA between December 2010 to June 2012. Image quality and motion artifact score (both on a Likert scale 1-4 with 4 being the best), effective dose, and CTDIvol were compared. The effect of heart rate (HR) and heart rate variability [HRV] on image motion artifact score and CTDIvol was analyzed with Pearson's correlation coefficient. All 82 exams were considered diagnostic with 0 non-diagnostic segments. PTA-systolic CTA patients had a higher maximum HR, wider HRV, were less likely to be in sinus rhythm, and received less beta-blocker vs. PTA-diastolic CTA patients. No difference in effective dose was observed (PTA-systolic vs. PTA-diastolic CTA: 2.9 vs. 2.2 mSv, p = 0.26). Image quality score (3.3 vs. 3.5, p < 0.05) and motion artifact score (3.5 vs. 3.8, p < 0.05) were lower in PTA-systolic CTAs than in PTA-diastolic CTAs. For PTA-systolic CTAs, an increase in HR was not associated with a negative impact on motion artifact score nor CTDIvol. For PTA-diastolic CTA, an increase in HR was associated with increased motion artifacts and CTDIvol. HRV demonstrated no correlation with motion artifact and CTDIvol for both PTA-systolic and PTA-diastolic CTAs. In conclusion, both PTA-diastolic CTA and PTA-systolic CTA yielded diagnostic examinations at unselected heart rates and rhythms with similar effective radiation, but PTA-systolic CTA resulted in more consistent radiation exposure and image quality across a wide range of rates and rhythms.

Entities:  

Mesh:

Year:  2013        PMID: 23526082     DOI: 10.1007/s10554-013-0208-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  30 in total

1.  Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Authors:  Xavier L Hamoir; Thomas Flohr; Vincent Hamoir; Laurent Labaki; Jean-Yves Tricquet; Alain Duhamel; Jacques Kirsch
Journal:  Eur Radiol       Date:  2004-11-24       Impact factor: 5.315

2.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

3.  Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol.

Authors:  Young Jean Park; Young Jin Kim; Ji Won Lee; Hee Yeong Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Ji Eun Nam; Byoung Wook Choi
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-06

4.  Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients.

Authors:  Ghazal Adler; Laurent Meille; Adela Rohnean; Anne Sigal-Cinqualbre; André Capderou; Jean-François Paul
Journal:  Eur Radiol       Date:  2009-11-05       Impact factor: 5.315

5.  The effect of heart rhythm on patient radiation dose with dual-source cardiac computed tomography.

Authors:  Tust Techasith; Brian B Ghoshhajra; Quynh A Truong; Rodrigo Pale; Khurram Nasir; Michael A Bolen; Udo Hoffmann; Ricardo C Cury; Suhny Abbara; Thomas J Brady; Ron Blankstein
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-05-25

6.  High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates.

Authors:  Robert Goetti; Gudrun Feuchtner; Paul Stolzmann; Lotus Desbiolles; Michael Alexander Fischer; Christoph Karlo; Stephan Baumueller; Hans Scheffel; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-06-29       Impact factor: 5.315

7.  Coronary computed tomography angiography during arrhythmia: Radiation dose reduction with prospectively ECG-triggered axial and retrospectively ECG-gated helical 128-slice dual-source CT.

Authors:  Ashley M Lee; Leif-Christopher Engel; Baiju Shah; Gary Liew; Manavjot S Sidhu; Mannudeep Kalra; Suhny Abbara; Thomas J Brady; Udo Hoffmann; Brian B Ghoshhajra
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-07

8.  Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality.

Authors:  Brian B Ghoshhajra; Leif-Christopher Engel; Mihály Károlyi; Manavjot Singh Sidhu; Bryan Wai; Mitya Barreto; Uthamalingam Shanmugam; Udo Hoffmann; Thomas J Brady; Manudeep Kalra; Suhny Abbara
Journal:  J Thorac Imaging       Date:  2013-01       Impact factor: 3.000

9.  Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography.

Authors:  Jose A Rocha-Filho; Ron Blankstein; Leonid D Shturman; Hiram G Bezerra; David R Okada; Ian S Rogers; Brian Ghoshhajra; Udo Hoffmann; Gudrun Feuchtner; Wilfred S Mamuya; Thomas J Brady; Ricardo C Cury
Journal:  Radiology       Date:  2010-02       Impact factor: 11.105

10.  Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates.

Authors:  H Brodoefel; A Reimann; M Heuschmid; A Küttner; T Beck; C Burgstahler; C D Claussen; S Schroeder; A F Kopp
Journal:  Eur Radiol       Date:  2006-02-24       Impact factor: 5.315

View more
  10 in total

1.  Epicardial adipose tissue is associated with high-risk plaque feature progression in non-culprit lesions.

Authors:  Yahang Tan; Jia Zhou; Ying Zhou; Xiaobo Yang; Jing Wang; Yundai Chen
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-26       Impact factor: 2.357

2.  Coronary CT angiography in patients with atrial fibrillation: Standard-dose and low-dose imaging with a high-resolution whole-heart CT scanner.

Authors:  Anna Matveeva; Rainer R Schmitt; Karoline Edtinger; Matthias Wagner; Sebastian Kerber; Thomas Deneke; Michael Uder; Sebastian Barth
Journal:  Eur Radiol       Date:  2018-02-09       Impact factor: 5.315

Review 3.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

4.  Advances in cardiac CT contrast injection and acquisition protocols.

Authors:  Jan-Erik Scholtz; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

5.  Coronary CTA using scout-based automated tube potential and current selection algorithm, with breast displacement results in lower radiation exposure in females compared to males.

Authors:  Harshna Vadvala; Phillip Kim; Thomas Mayrhofer; Oleg Pianykh; Mannudeep Kalra; Udo Hoffmann; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2014-12

6.  Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography.

Authors:  Csilla Celeng; Harshna Vadvala; Stefan Puchner; Amit Pursnani; Umesh Sharma; Attila Kovacs; Pâl Maurovich-Horvat; Udo Hoffmann; Brian Ghoshhajra
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-03       Impact factor: 2.357

7.  Salvage of diagnostic quality of image acquired by low-radiation-dose prospectively ECG-triggered coronary CTA during ventricular trigeminy: A case report of a novel image processing method.

Authors:  Harshna V Vadvala; Karl Sayegh; Matthew Moy; Pedro Vinícius Staziaki; Brian B Ghoshhajra
Journal:  HeartRhythm Case Rep       Date:  2015-09-15

8.  Characteristics Detected on Computed Tomography Angiography Predict Coronary Artery Plaque Progression in Non-Culprit Lesions.

Authors:  Yahang Tan; Jia Zhou; Ying Zhou; Xiaobo Yang; Junjie Yang; Yundai Chen
Journal:  Korean J Radiol       Date:  2017-04-03       Impact factor: 3.500

9.  Feasibility of aortic valve assessment with low dose prospectively triggered adaptive systolic (PTAS) cardiac computed tomography angiography.

Authors:  Ashley M Lee; Jonathan Beaudoin; Wai-Ee Thai; Bryan Wai; Gladwin C Hui; Manavjot S Sidhu; Leif-Christopher Engel; Suhny Abbara; Udo Hoffmann; Brian B Ghoshhajra
Journal:  BMC Res Notes       Date:  2013-04-20

10.  Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals?

Authors:  Xiao-Ping Wang; Xiao-Mei Zhu; Yin-Su Zhu; Wang-Yan Liu; Xiao-Han Yang; Wei-Wei Huang; Yi Xu; Li-Jun Tang
Journal:  Exp Ther Med       Date:  2018-05-11       Impact factor: 2.447

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.