Literature DB >> 24884727

Feasibility of a radiation dose conserving CT protocol for myocardial function assessment.

A Pursnani1, A Lee, T Mayrhofer, M Panagia, U Sharma, S Abbara, U Hoffmann, B B Ghoshhajra.   

Abstract

OBJECTIVE: Assessment of myocardial function can be performed at higher noise levels than necessary for coronary arterial evaluation. We evaluated image quality and radiation exposure of a dose-conserving function-only acquisition vs retrospectively electrocardiogram(ECG)-gated coronary CTA with automatic tube current modulation.
METHODS: Of 26 patients who underwent clinically indicated coronary CTA for coronary and function evaluation, 13 (Group I) underwent prospectively ECG-triggered coronary CTA, followed by low-dose retrospectively ECG-gated scan for function (128-slice dual-source, 80 kVp; reference tube current, 100 mA; 8-mm-thick multiplanar reformatted reconstructions) performed either immediately (n = 6) or after 5- to 10-min delay for infarct assessment (n = 7). 13 corresponding controls (Group II) underwent retrospectively ECG-gated protocols (automatic tube potential selection with CARE kV/CARE Dose 4D; Siemens Healthcare, Forchheim, Germany) with aggressive dose modulation. Image quality assessment was performed on the six Group I subjects who underwent early post-contrast dedicated function scan and corresponding controls. Radiation exposure was based on dose-length product.
RESULTS: Contrast-to-noise ratio (CNR) was preserved throughout the cardiac cycle in Group I and varied according to dose modulation in Group II. Visual image quality indices were similar during end systole but were better in Group II at end diastole. Although the total radiation exposure was equivalent in Group I and Group II (284 vs 280 mGy cm), the median radiation exposure associated with only the dedicated function scan was 138 mGy cm (interquartile range, 116-203 mGy cm).
CONCLUSION: A low-dose retrospective ECG-gated protocol permits assessment of myocardial function at a median radiation exposure of 138 mGy cm and offers more consistent multiphase CNR vs traditional ECG-modulation protocols. This is useful for pure functional evaluation or as an adjunct to single-phase scan modes. ADVANCES IN KNOWLEDGE: Radiation exposure can be limited with a tailored myocardial function CT protocol while maintaining preserved images.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24884727      PMCID: PMC4112222          DOI: 10.1259/bjr.20130755

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  Comparison of dual-source 64-slice adenosine stress CT perfusion with stress-gated SPECT-MPI for evaluation of left ventricular function and volumes.

Authors:  Shanmugam Uthamalingam; Gagandeep S Gurm; Manavjot S Sidhu; Daniel J Verdini; Yongkasem Vorasettakarnkij; Leif-Christopher Engel; Ron Blankstein; Wilfred S Mamuya; Udo Hoffman; Thomas J Brady; Ricardo C Cury; Brian B Ghoshhajra
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-11-18

2.  Multi-detector row cardiac computed tomography accurately quantifies right and left ventricular size and function compared with cardiac magnetic resonance.

Authors:  Subha V Raman; Mona Shah; Beth McCarthy; Anne Garcia; Amy K Ferketich
Journal:  Am Heart J       Date:  2006-03       Impact factor: 4.749

3.  Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure.

Authors:  Javed Butler; Michael D Shapiro; Davinder S Jassal; Davindar Jassal; Tomas G Neilan; Tomas Neilan; John Nichols; Maros Ferencik; Thomas J Brady; Udo Hoffmann; Ricardo C Cury
Journal:  Am J Cardiol       Date:  2006-11-27       Impact factor: 2.778

4.  Assessment of global left and right ventricular function using dual-source computed tomography (DSCT) in comparison to MRI: an experimental study in a porcine model.

Authors:  Philipp Bruners; Andreas H Mahnken; Christian Knackstedt; Nadja Luhmann; Elmar Spüntrup; Marco Das; Christian Hohl; Joachim E Wildberger; Thomas Schmitz-Rode; Rolf W Günther; Georg Mühlenbruch
Journal:  Invest Radiol       Date:  2007-11       Impact factor: 6.016

5.  Estimation of global and regional cardiac function using 64-slice computed tomography: a comparison study with echocardiography, gated-SPECT and cardiovascular magnetic resonance.

Authors:  Yen-Wen Wu; Eiji Tadamura; Masaki Yamamuro; Shotaro Kanao; Satoshi Okayama; Neiko Ozasa; Masanao Toma; Takeshi Kimura; Masashi Komeda; Kaori Togashi
Journal:  Int J Cardiol       Date:  2007-08-10       Impact factor: 4.164

6.  Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study.

Authors:  Jörg Hausleiter; Tanja S Meyer; Eugenio Martuscelli; Pietro Spagnolo; Hiroaki Yamamoto; Patricia Carrascosa; Thomas Anger; Lukas Lehmkuhl; Hatem Alkadhi; Stefan Martinoff; Martin Hadamitzky; Franziska Hein; Bernhard Bischoff; Miriam Kuse; Albert Schömig; Stephan Achenbach
Journal:  JACC Cardiovasc Imaging       Date:  2012-05

7.  Incremental diagnostic value of regional left ventricular function over coronary assessment by cardiac computed tomography for the detection of acute coronary syndrome in patients with acute chest pain: from the ROMICAT trial.

Authors:  Sujith K Seneviratne; Quynh A Truong; Fabian Bamberg; Ian S Rogers; Michael D Shapiro; Christopher L Schlett; Claudia U Chae; Ricardo Cury; Suhny Abbara; Thomas J Brady; John T Nagurney; Udo Hoffmann
Journal:  Circ Cardiovasc Imaging       Date:  2010-05-19       Impact factor: 7.792

8.  Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a population-based analysis.

Authors:  Jersey Chen; Andrew J Einstein; Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Henry H Ting; Nilay D Shah; Khurram Nasir; Brahmajee K Nallamothu
Journal:  J Am Coll Cardiol       Date:  2010-07-09       Impact factor: 24.094

9.  Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality.

Authors:  Brian B Ghoshhajra; Leif-Christopher Engel; Mihály Károlyi; Manavjot Singh Sidhu; Bryan Wai; Mitya Barreto; Uthamalingam Shanmugam; Udo Hoffmann; Thomas J Brady; Manudeep Kalra; Suhny Abbara
Journal:  J Thorac Imaging       Date:  2013-01       Impact factor: 3.000

10.  Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) Registry.

Authors:  M Emond; M B Mock; K B Davis; L D Fisher; D R Holmes; B R Chaitman; G C Kaiser; E Alderman; T Killip
Journal:  Circulation       Date:  1994-12       Impact factor: 29.690

View more
  2 in total

Review 1.  Analysis of ventricular function by CT.

Authors:  Asim Rizvi; Roderick C Deaño; Daniel P Bachman; Guanglei Xiong; James K Min; Quynh A Truong
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-11-26

2.  Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.