The use of constrained components in total hip arthroplasty.

Paul F Lachiewicz1, Scott S Kelley.   

Abstract

The use of a constrained component may be appropriate for the surgical treatment of recurrent dislocation due to soft-tissue insufficiency following a total hip arthroplasty. Constrained components usually include a locking mechanism incorporated into the polyethylene acetabular liner to keep the prosthetic femoral head in place. Two different prosthetic designs are available and have been approved by the U.S. Food and Drug Administration. The S-ROM constrained component uses additional polyethylene in the rim, which deforms to more fully capture the femoral head and then is held in place by a metal locking ring. The Howmedica Osteonics constrained component is a tripolar device; its bipolar component articulates with another polyethylene liner. These constrained components transfer hip forces that would otherwise lead to dislocation to the locking mechanism, the liner-shell interface, or the bone-prosthesis interface. These forces may eventually contribute to failure of the component due to loosening, dissociation, breakage, or recurrent dislocation. Studies of these components show a failure rate of 4% to 29% at relatively short-term follow-up.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 15089072     DOI: 10.5435/00124635-200207000-00001

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  4 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions.

Authors:  Roberto Civinini; Christian Carulli; Fabrizio Matassi; Lorenzo Nistri; Massimo Innocenti
Journal:  Clin Orthop Relat Res       Date:  2012-06-15       Impact factor: 4.176

3.  Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series.

Authors:  Ji-Hyo Hwang; Sang-Min Kim; Kwang-Jun Oh; Yeesuk Kim
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

4.  Catastrophic failure of tripolar constrained liners due to backside wear: a novel failure mode.

Authors:  Christopher W Jones; Michael-Alexander Malahias; Elexis Baral; Timothy Wright; Thomas P Sculco; Peter K Sculco
Journal:  Arthroplast Today       Date:  2018-05-18