Literature DB >> 31758218

Dual mobility constructs in revision total hip arthroplasty: survivorship analysis in recurrent dislocation versus other indications at three to twelve-year follow-up.

Nicolas de l'Escalopier1, Valérie Dumaine2, Guillaume Auberger2, Antoine Babinet2, Jean-Pierre Courpied2, Philippe Anract2, Moussa Hamadouche2.   

Abstract

BACKGROUND: The aim of this retrospective study was to evaluate the clinical, radiologic, and survival results of dual mobility (DM) sockets in revision total hip arthroplasty (THA) performed for instability versus revision THAs performed for other reasons.
METHODS: From a computerized database, we identified 84 revision THAs using a modern DM socket performed in 81 patients with a mean age of 71 years. Indication for revision was recurrent dislocation in 47 hips, and other reasons in the remaining 37 hips. A survivorship analysis according to the actuarial method was carried out on the entire series using revision for any cause, revision for dislocation, and radiological cup loosening revised or not, as the end points.
RESULTS: Of the 81 patients, twelve died, six were lost to follow-up, eight had been revised, and 55 patients (58 hips) were unrevised and alive at a mean follow-up of 6.4 years. Dislocation occurred in four of the 47 (8.5%) hips for which indication for revision was dislocation versus one of the remaining 37 (2.7%) hips [odds ratio = 3.4 (0.4-31.3), p = 0.07]. According to our criteria, three acetabular components of which one was revised were considered as loosened. When using revision for dislocation as the end-point, the survival rate at seven years was 90.4 ± 5.3% (IC95%, 79.9-100) in the 47 hips for which the indication for revision was dislocation versus 100% in the remaining 37 hips (log-rank, p = 0.5).
CONCLUSIONS: The current study indicated that DM sockets represent an interesting solution to prevent dislocation in revision THAs at mid-term follow-up.

Entities:  

Keywords:  Dislocation; Dual mobility cup; Revision; Total hip arthroplasty

Mesh:

Year:  2019        PMID: 31758218     DOI: 10.1007/s00264-019-04445-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  The double-mobility acetabular component in revision total hip replacement: the United Kingdom experience.

Authors:  N L Vasukutty; R G Middleton; E C Matthews; P S Young; C E Uzoigwe; T H A Minhas
Journal:  J Bone Joint Surg Br       Date:  2012-05

2.  Use of a dual mobility socket to manage total hip arthroplasty instability.

Authors:  Olivier Guyen; Vincent Pibarot; Gualter Vaz; Christophe Chevillotte; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2008-09-09       Impact factor: 4.176

3.  Can Dual Mobility Cups prevent Dislocation in All Situations After Revision Total Hip Arthroplasty?

Authors:  Julien Wegrzyn; Eloïse Tebaa; Alexandre Jacquel; Jean-Paul Carret; Jacques Béjui-Hugues; Vincent Pibarot
Journal:  J Arthroplasty       Date:  2014-11-10       Impact factor: 4.757

4.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

5.  Total hip arthroplasty revision by dual-mobility acetabular cup cemented in a metal reinforcement: A 62 case series at a minimum 5 years' follow-up.

Authors:  N Lebeau; M Bayle; R Belhaouane; M Chelli; E Havet; B Brunschweiler; P Mertl
Journal:  Orthop Traumatol Surg Res       Date:  2017-05-31       Impact factor: 2.256

6.  Early complications after revision total hip arthroplasty with cemented dual-mobility socket and reinforcement ring.

Authors:  Christophe Pattyn; Emmanuel Audenaert
Journal:  Acta Orthop Belg       Date:  2012-06       Impact factor: 0.500

7.  Prevention of dislocation in total hip revision surgery using a dual mobility design.

Authors:  R Philippot; P Adam; M Reckhaus; F Delangle; F -X Verdot; G Curvale; F Farizon
Journal:  Orthop Traumatol Surg Res       Date:  2009-08-04       Impact factor: 2.256

8.  Dual mobility cemented cups have low dislocation rates in THA revisions.

Authors:  Frantz L Langlais; Mickaël Ropars; François Gaucher; Thierry Musset; Olivier Chaix
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

9.  Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1-5 years.

Authors:  M van Heumen; P J C Heesterbeek; B A Swierstra; G G Van Hellemondt; J H M Goosen
Journal:  J Orthop Traumatol       Date:  2014-09-24

10.  The dislocating hip replacement - revision with a dual mobility cup in 56 consecutive patients.

Authors:  Thomas Jakobsen; Andreas Kappel; Flemming Hansen; Niels Krarup
Journal:  Open Orthop J       Date:  2014-09-11
View more
  2 in total

1.  The Patient With Chronic Total Hip Arthroplasty Dislocations: A Case Series of Five Patients Who Underwent Revision THA Using Polypropylene Mesh for Capsular Reconstruction.

Authors:  Joseph M Nessler; Joseph P Nessler
Journal:  Arthroplast Today       Date:  2020-08-22

2.  Study protocol: Effectiveness of dual-mobility cups compared with uni-polar cups for preventing dislocation after primary total hip arthroplasty in elderly patients - design of a randomized controlled trial nested in the Dutch Arthroplasty Registry.

Authors:  Loes W A H Van Beers; Bart C H Van Der Wal; Tess Glastra Van Loon; Dirk Jan F Moojen; Marieke F Van Wier; Amanda D Klaassen; Nienke W Willigenburg; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2020-08-04       Impact factor: 3.717

  2 in total