Literature DB >> 22693040

Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

Jarred Kaiser1, Robert Bradford, Kevin Johnson, Oliver Wieben, Darryl G Thelen.   

Abstract

This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load acceptance phase of gait. Volumetric images were continuously acquired for 5 min using a 3D cine spoiled gradient-echo sequence in conjunction with vastly under-sampled isotropic projection reconstruction. Knee angle was simultaneously monitored and used retrospectively to sort images into 60 frames over the motion cycle. High-resolution static knee images were acquired and segmented to create subject-specific models of the femur and tibia. At each time frame, bone positions and orientations were determined by automatically registering the skeletal models to the dynamic images. Three-dimensional tibiofemoral translations and rotations were consistent across healthy subjects. Internal tibia rotations of 7.8±3.5° were present with 35.8±3.8° of knee flexion, a pattern consistent with knee kinematic measures during walking. We conclude that vastly under-sampled isotropic projection reconstruction imaging is a promising approach for noninvasively measuring 3D joint kinematics, which may be useful for assessing cartilage contact and investigating the causes and treatment of joint abnormalities.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22693040      PMCID: PMC4159195          DOI: 10.1002/mrm.24362

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  The finite helical axis of the knee joint (a non-invasive in vivo study using fast-PC MRI).

Authors:  Frances T Sheehan
Journal:  J Biomech       Date:  2006-12-04       Impact factor: 2.712

2.  A Magnetic Resonance-Compatible Loading Device for Dynamically Imaging Shortening and Lengthening Muscle Contraction Mechanics.

Authors:  Amy Silder; Christopher J Westphal; Darryl G Thelen
Journal:  J Med Device       Date:  2009-09-01       Impact factor: 0.582

3.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

4.  The "screw-home" movement in the knee-joint.

Authors:  L G Hallén; O Lindahl
Journal:  Acta Orthop Scand       Date:  1966

5.  Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human knee.

Authors:  Daniel L Miranda; Michael J Rainbow; Evan L Leventhal; Joseph J Crisco; Braden C Fleming
Journal:  J Biomech       Date:  2010-02-18       Impact factor: 2.712

Review 6.  The long-term consequence of anterior cruciate ligament and meniscus injuries: osteoarthritis.

Authors:  L Stefan Lohmander; P Martin Englund; Ludvig L Dahl; Ewa M Roos
Journal:  Am J Sports Med       Date:  2007-08-29       Impact factor: 6.202

7.  Using real-time MRI to quantify altered joint kinematics in subjects with patellofemoral pain and to evaluate the effects of a patellar brace or sleeve on joint motion.

Authors:  Christine E Draper; Thor F Besier; Juan M Santos; Fabio Jennings; Michael Fredericson; Garry E Gold; Gary S Beaupre; Scott L Delp
Journal:  J Orthop Res       Date:  2009-05       Impact factor: 3.494

8.  Feasibility of using real-time MRI to measure joint kinematics in 1.5T and open-bore 0.5T systems.

Authors:  Christine E Draper; Juan M Santos; Lampros C Kourtis; Thor F Besier; Michael Fredericson; Gary S Beaupre; Garry E Gold; Scott L Delp
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

9.  Knee muscle forces during walking and running in patellofemoral pain patients and pain-free controls.

Authors:  Thor F Besier; Michael Fredericson; Garry E Gold; Gary S Beaupré; Scott L Delp
Journal:  J Biomech       Date:  2009-03-06       Impact factor: 2.712

10.  The influence of muscle load on tibiofemoral knee kinematics.

Authors:  Jan Victor; Luc Labey; Pius Wong; Bernardo Innocenti; Johan Bellemans
Journal:  J Orthop Res       Date:  2010-04       Impact factor: 3.494

View more
  9 in total

1.  American Society of Biomechanics Clinical Biomechanics Award 2017: Non-anatomic graft geometry is linked with asymmetric tibiofemoral kinematics and cartilage contact following anterior cruciate ligament reconstruction.

Authors:  Michael F Vignos; Jarred M Kaiser; Geoffrey S Baer; Richard Kijowski; Darryl G Thelen
Journal:  Clin Biomech (Bristol, Avon)       Date:  2018-05-10       Impact factor: 2.063

2.  Kinematic change of the meniscus and the tibiofemoral joint space in asymptomatic volunteers using a wide bore 3T closed MRI system.

Authors:  Eugene Kim; Yeo Ju Kim; Jang Gyu Cha; Mi Young Kim; Dae Hyung Lee; Soon Gu Cho; Ryuh Sup Kim
Journal:  Skeletal Radiol       Date:  2015-06-16       Impact factor: 2.199

3.  The effect of articular geometry features identified using statistical shape modelling on knee biomechanics.

Authors:  Allison L Clouthier; Colin R Smith; Michael F Vignos; Darryl G Thelen; Kevin J Deluzio; Michael J Rainbow
Journal:  Med Eng Phys       Date:  2019-03-06       Impact factor: 2.242

4.  Prediction and Validation of Load-Dependent Behavior of the Tibiofemoral and Patellofemoral Joints During Movement.

Authors:  Rachel L Lenhart; Jarred Kaiser; Colin R Smith; Darryl G Thelen
Journal:  Ann Biomed Eng       Date:  2015-04-28       Impact factor: 3.934

5.  Effect of Loading on In Vivo Tibiofemoral and Patellofemoral Kinematics of Healthy and ACL-Reconstructed Knees.

Authors:  Jarred M Kaiser; Michael F Vignos; Richard Kijowski; Geoffrey Baer; Darryl G Thelen
Journal:  Am J Sports Med       Date:  2017-09-13       Impact factor: 6.202

6.  American Society of Biomechanics Clinical Biomechanics Award 2015: MRI assessments of cartilage mechanics, morphology and composition following reconstruction of the anterior cruciate ligament.

Authors:  Jarred Kaiser; Michael F Vignos; Fang Liu; Richard Kijowski; Darryl G Thelen
Journal:  Clin Biomech (Bristol, Avon)       Date:  2016-03-31       Impact factor: 2.063

7.  Biomechanical model of knee collateral ligament injury with six degrees of freedom.

Authors:  Neriman Ozada
Journal:  Med Biol Eng Comput       Date:  2015-08-26       Impact factor: 2.602

8.  Accuracy of model-based tracking of knee kinematics and cartilage contact measured by dynamic volumetric MRI.

Authors:  Jarred Kaiser; Arezu Monawer; Rajeev Chaudhary; Kevin M Johnson; Oliver Wieben; Richard Kijowski; Darryl G Thelen
Journal:  Med Eng Phys       Date:  2016-07-04       Impact factor: 2.242

Review 9.  Real-Time Magnetic Resonance Imaging.

Authors:  Krishna S Nayak; Yongwan Lim; Adrienne E Campbell-Washburn; Jennifer Steeden
Journal:  J Magn Reson Imaging       Date:  2020-12-09       Impact factor: 4.813

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.